In Vitro Comparison of the Cytotoxicity of Acetal Resin, Heat-Polymerized Resin, and Auto-Polymerized Resin as Denture Base Materials

被引:31
作者
Ata, Secil Ozkan [1 ]
Yavuzyilmaz, Huesnue [1 ]
机构
[1] Gazi Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
关键词
acetal resin; cell culture; cytotoxicity; denture base material; acrylic resin; RESIDUAL MONOMER LEVELS; ACRYLIC RESINS; CELL-LINE; BIOCOMPATIBILITY; FORMALDEHYDE; FIBROBLASTS; PERFORMANCE; DELRIN(R); CULTURE; CYCLE;
D O I
10.1002/jbm.b.31473
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This in vitro study aims to evaluate three different base materials (acetal, heat-polymerized, and auto-polymerized resins) on L-929 mouse fibroblast cells over 1 h-, 1-, 3-, 5-, 7-day periods. The hypothesis was that acetal resin would show higher cytotoxic effect than heat-polymerized and auto-polymerized acrylic resins, as it seems possible that residual formaldehyde might be leaching from the material into the cell culture medium. The samples were produced according to the manufacturer's protocol. Then they were placed in Dulbecco's Modified Eagle Medium/Ham's F12 (DMEM/F12) for 1 h, 1, 3, 5, 7 days. After the incubation periods, cytotoxicity of the extracts to cultured fibroblasts (L-929) was measured by MTT assay. The degree of cytotoxicity of each sample was determined according to the reference value represented by the cells with a control. Statistical significance was determined by one-way ANOVA. Tukey and Tamhane tests were used as a post-hoe method to determine differences among the groups. Statistically significant difference was found among test groups at all time incubation periods (p = 0.000). The auto-polymerized resin performed higher cytotoxic effect than heat-polymerized resin and it was statistically significant at I-day period (p < 0.05). The highest cytotoxic effect of acetal resin was observed at 5-day incubation period. In conclusion, the hypothesis was verified, since acetal resin showed more cytotoxic effect on the 3rd, 5th, and 7th days than heat- and auto-polymerized resins. Cell survival rates (% of control) of acetal resin were 58, 54, and 60%, respectively. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 91B: 905-909, 2009
引用
收藏
页码:905 / 909
页数:5
相关论文
共 32 条
  • [1] P-2u purinoceptor regulation of mucin secretion in SPOC1 cells, a goblet cell line from the airways
    Abdullah, LH
    Davis, SW
    Burch, L
    Yamauchi, M
    Randell, SH
    Nettesheim, P
    Davis, CW
    [J]. BIOCHEMICAL JOURNAL, 1996, 316 : 943 - 951
  • [2] Micro-perfusion flow cell for imaging cultured cells
    Agnihotri, N
    Kisaalita, WS
    Keith, CH
    [J]. BIOTECHNIQUES, 1999, 27 (04) : 722 - +
  • [3] Degree of conversion in denture base materials for varied polymerization techniques
    Bartoloni, JA
    Murchison, DF
    Wofford, DT
    Sarkar, NK
    [J]. JOURNAL OF ORAL REHABILITATION, 2000, 27 (06) : 488 - 493
  • [4] Microwave polymerization of denture base materials. A comparative study
    Blagojevic, V
    Murphy, VM
    [J]. JOURNAL OF ORAL REHABILITATION, 1999, 26 (10) : 804 - 808
  • [5] Long-term cytotoxicity of resin-based dental restorative materials
    Bouillaguet, S
    Shaw, L
    Gonzalez, L
    Wataha, JC
    Krejci, I
    [J]. JOURNAL OF ORAL REHABILITATION, 2002, 29 (01) : 7 - 13
  • [6] EFFECTS OF DIRECT CURRENTS ON BONE-GROWTH INTO DELRIN IMPLANTS
    BUCH, F
    ALBREKTSSON, T
    HERBST, E
    [J]. SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1985, 19 (03): : 223 - 230
  • [7] The effect of heat- and auto-polymerized denture base polymers on clonogenicity, apoptosis, and necrosis in fibroblasts: denture base polymers induce apoptosis and necrosis
    Cimpan, MR
    Matre, R
    Cressey, LI
    Tysnes, B
    Lie, SA
    Gjertsen, BT
    Skaug, N
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 2000, 58 (05) : 217 - 228
  • [8] BIOCOMPATIBILITY OF DELRIN 150 - A CREEP-RESISTANT POLYMER FOR TOTAL JOINT PROSTHESES
    FISTER, JS
    MEMOLI, VA
    GALANTE, JO
    ROSTOKER, W
    URBAN, RM
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (05): : 519 - 533
  • [9] THE PHYSICAL-PROPERTIES OF A POLYACETAL DENTURE RESIN
    FITTON, JS
    DAVIES, EH
    HOWLETT, JA
    PEARSON, GJ
    [J]. CLINICAL MATERIALS, 1994, 17 (03): : 125 - 129
  • [10] BIOCOMPATIBILITY OF POLYOXYMETHYLENE (DELRIN(R)) IN BONE
    GASSER, B
    MISTELI, G
    MATHYS, R
    [J]. BIOMATERIALS, 1993, 14 (15) : 1188 - 1189