Ratiometric Array of Conjugated Polymers-Fluorescent Protein Provides a Robust Mammalian Cell Sensor

被引:122
|
作者
Rana, Subinoy [1 ,2 ]
Elci, S. Gokhan [1 ]
Mout, Rubul [1 ]
Singla, Arvind K. [3 ]
Yazdani, Mandieh [1 ]
Bender, Markus [4 ]
Bajaj, Avinash [1 ,5 ]
Saha, Krishnendu [1 ]
Bunz, Uwe H. F. [4 ]
Jirik, Frank R. [3 ]
Rotello, Vincent M. [1 ]
机构
[1] Univ Massachusetts, Dept Chem, 710 North Pleasant St, Amherst, MA 01003 USA
[2] Univ London Imperial Coll Sci Technol & Med, Dept Mat, London SW7 2AZ, England
[3] Univ Calgary, Arnie Charbonneau Canc Inst, McCaig Inst Bone & Joint Hlth, Dept Biochem & Mol Biol, Calgary, AB T2N 1N4, Canada
[4] Heidelberg Univ, Inst Organ Chem, Neuenheimer Feld 270, D-69120 Heidelberg, Germany
[5] Reg Ctr Biotechnol, Lab Nanotechnol & Chem Biol, 180 Udyog Vihar,Phase I, Gurgaon 122016, Haryana, India
关键词
RESONANCE ENERGY-TRANSFER; CANCER-CELLS; METASTATIC CELLS; COLORIMETRIC IDENTIFICATION; GOLD-NANOPARTICLE; CHEMICAL SENSORS; BREAST-CANCER; DNA DETECTION; AMINO-ACIDS; LABEL-FREE;
D O I
10.1021/jacs.6b00067
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Supramolecular complexes of a family of positively charged conjugated polymers (CPs) and green fluorescent.protein (GFP) create a fluorescence resonance energy transfer (FRET)-based ratiometric biosensor array. Selective multivalent interactions of the CPs with mammalian cell surfaces caused differential change in FRET signals, providing a fingerprint signature for each cell type. The resulting fluorescence signatures allowed the identification of 16 different cell types and discrimination between healthy, cancerous, and metastatic cells, with the same genetic background. While the CP-GFP sensor array completely differentiated between the cell types, only partial classification was achieved for the CPs alone, validating the effectiveness of the ratiometric sensor. The utility of the biosensor was further demonstrated in the detection of blinded unknown samples, where 121 of 128 samples were correctly identified. Notably, this selectivity-based sensor stratified diverse cell types in minutes, using only 2000 cells, without requiring specific biomarkers or cell labeling.
引用
收藏
页码:4522 / 4529
页数:8
相关论文
共 50 条
  • [11] A novel ratiometric fluorescent sensor array based on the copper clusters hydrogels coupling of DNA
    Cao, Haiyan
    Dong, Wenfei
    Shi, Si
    Shi, Wenbing
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 327
  • [12] A ratiometric fluorescent biosensor based on conjugated polymers for sensitive detection of nitroreductase and hypoxia diagnosis in tumor cells
    Zhang, Ziqi
    Feng, Qian
    Yang, Min
    Tang, Yanli
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 318
  • [13] Engineering a Ratiometric Fluorescent Protein Sensor of Extracellular ATP to Study Purinergic Signaling
    Cholger, Dan
    Conley, Jason
    Valentino, Stephan
    PROTEIN SCIENCE, 2018, 27 : 57 - 58
  • [14] Multicolor Gold Clusterzyme-Enabled Construction of Ratiometric Fluorescent Sensor Array for Visual Biosensing
    Zhou, Xiaomeng
    Huang, Saijin
    Guo, Wenfeng
    Liu, Wenfeng
    Wen, Mengyao
    Shang, Li
    ANALYTICAL CHEMISTRY, 2024, 96 (47) : 18873 - 18879
  • [15] A colorimetric and ratiometric fluorescent sensor for biogenic primary amines based on dicyanovinyl substituted phenanthridine conjugated probe
    Saravanakumar, Manickam
    Umamahesh, Balijapalli
    Selvakumar, Ramasamy
    Dhanapal, Jothi
    Kumar, S. K. Ashok
    Sathiyanarayanan, Kulathu Iyer
    DYES AND PIGMENTS, 2020, 178
  • [16] Water soluble non-conjugated fluorescent polymers: aggregation induced emission, solid-state fluorescence, and sensor array applications
    Jose, Anna
    Tharayil, Adithya
    Porel, Mintu
    POLYMER CHEMISTRY, 2023, 14 (28) : 3309 - 3316
  • [17] Two-Dimensional, Acene-Containing Conjugated Polymers That Show Ratiometric Fluorescent Response to Singlet Oxygen
    Altinok, Esra
    Smith, Zachary C.
    Thomas, Samuel W., III
    MACROMOLECULES, 2015, 48 (19) : 6825 - 6831
  • [18] Fluorescent protein Dendra2 as a ratiometric genetically encoded pH-sensor
    Pakhomov, Alexey A.
    Martynov, Vladimir I.
    Orsa, Alexander N.
    Bondarenko, Alena A.
    Chertkova, Rita V.
    Lukyanov, Konstantin A.
    Petrenko, Alexander G.
    Deyev, Igor E.
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2017, 493 (04) : 1518 - 1521
  • [19] Fluorescent protein from Dendronephthya sp as a ratiometric green/red emitting pH sensor
    Martynov, V. I.
    Pakhomov, A. A.
    Chertkova, R. V.
    Deyev, I. E.
    Petrenko, A. G.
    FEBS JOURNAL, 2017, 284 : 320 - 320
  • [20] Array-Based Sensing of Normal, Cancerous, and Metastatic Cells Using Conjugated Fluorescent Polymers
    Bajaj, Avinash
    Miranda, Oscar R.
    Phillips, Ronnie
    Kim, Ik-Bum
    Jerry, D. Joseph
    Bunz, Uwe H. F.
    Rotello, Vincent M.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2010, 132 (03) : 1018 - 1022