Axial line-scanning stimulated emission depletion fluorescence correlation spectroscopy

被引:0
|
作者
Gao, Peng [1 ,2 ,3 ]
Nienhaus, G. Ulrich [1 ,2 ,4 ,5 ]
机构
[1] Karlsruhe Inst Technol, Inst Appl Phys, D-76049 Karlsruhe, Germany
[2] Karlsruhe Inst Technol, Inst Nanotechnol, D-76021 Karlsruhe, Germany
[3] Xidian Univ, Sch Phys & Optoelect Engn, Xian 710071, Peoples R China
[4] Karlsruhe Inst Technol, Inst Biol & Chem Syst, D-76021 Karlsruhe, Germany
[5] Univ Illinois, Dept Phys, Urbana, IL 61801 USA
关键词
RECEPTOR-LIGAND INTERACTIONS; MEMBRANE DYNAMICS; FCS; DIFFUSION; NANOSCOPY;
D O I
10.1364/OL.420765
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Investigating the dynamics and interactions of biomolecules within or attached to membranes of living cells is crucial for understanding biology at the molecular level. In this pursuit, classical, diffraction-limited optical fluorescence microscopy is widely used, but it faces limitations due to (1) the heterogeneity of biomembranes on the nanoscale and (2) the intrinsic motion of membranes with respect to the focus. Here we introduce a new confocal microscopy-based fluctuation spectroscopy technique aimed at alleviating these two problems, called axial line-scanning stimulated emission depletion fluorescence correlation spectroscopy (axial ls-STED-FCS). Axial line scanning by means of a tunable acoustic gradient index of refraction lens provides a time resolution of a few microseconds, which is more than two orders of magnitude greater than that of conventional, lateral line-scanning fluorescence correlation spectroscopy (typically around 1 ms). Using STED excitation, the observation area on the membrane can be reduced 10-100 fold, resulting in sub-diffraction spatial resolution and the ability to study samples with densely labeled membranes. Due to these attractive properties, we expect that the axial ls-STED-FCS will find wide application, especially in the biomolecular sciences. (C) 2021 Optical Society of America
引用
收藏
页码:2184 / 2187
页数:4
相关论文
共 50 条
  • [21] ABERRATION CORRECTED BEAM SCANNING STIMULATED EMISSION DEPLETION MICROSCOPY
    Yoo, Hongki
    Song, Incheon
    Gweon, Dae-Gab
    INTERNATIONAL JOURNAL OF OPTOMECHATRONICS, 2008, 2 (04) : 401 - 412
  • [22] Correlative Stimulated Emission Depletion and Scanning Ion Conductance Microscopy
    Hagemann, Philipp
    Gesper, Astrid
    Happel, Patrick
    ACS NANO, 2018, 12 (06) : 5807 - 5815
  • [23] Spatially Resolved Recording of Transient Fluorescence-Lifetime Effects by Line-Scanning TCSPC
    Becker, Wolfgang
    Su, Bertram
    Bergmann, Axel
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES XII, 2012, 8226
  • [24] Enhancing the applicability of fluorescence fluctuation spectroscopy through reduced focal volumes generated by stimulated emission depletion
    Eggeling, C
    Kastrup, L
    Blom, H
    Hell, SW
    BIOPHYSICAL JOURNAL, 2005, 88 (01) : 662A - 662A
  • [25] Background suppression in fluorescence nanoscopy with stimulated emission double depletion
    Gao, Peng
    Prunsche, Benedikt
    Zhou, Lu
    Nienhaus, Karin
    Nienhaus, G. Ulrich
    NATURE PHOTONICS, 2017, 11 (03) : 163 - +
  • [26] Background suppression in fluorescence nanoscopy with stimulated emission double depletion
    Gao P.
    Prunsche B.
    Zhou L.
    Nienhaus K.
    Nienhaus G.U.
    Nature Photonics, 2017, 11 (3) : 163 - 169
  • [27] A line-scanning multiphoton fluorescence spectromicroscope applied to the study of the thylakoid membrane in cyanobacteria and chloroplasts
    Kumazaki, S.
    Hasegawa, M.
    Ghoneim, M.
    Terazima, M.
    Oh-Oka, H.
    Shiina, T.
    PHOTOSYNTHESIS RESEARCH, 2007, 91 (2-3) : 211 - 211
  • [28] Circular scanning fluorescence correlation spectroscopy on membranes
    Petrasek, Zdenek
    Derenko, Susan
    Schwille, Petra
    OPTICS EXPRESS, 2011, 19 (25): : 25006 - 25021
  • [29] Phase sensitive scanning fluorescence correlation spectroscopy
    Skinner, J
    Müller, JD
    BIOPHYSICAL JOURNAL, 2004, 86 (01) : 158A - 158A
  • [30] Spatially Resolved Recording of Transient Fluorescence-Lifetime Effects by Line-Scanning TCSPC
    Becker, Wolfgang
    Shcheslavkiy, Vladislav
    Frere, Samuel
    Slutsky, Inna
    MICROSCOPY RESEARCH AND TECHNIQUE, 2014, 77 (03) : 216 - 224