Reproducibility of temporal volume change in CT of lung cancer: comparison of computer software and manual assessment

被引:5
作者
Honda, O. [1 ]
Kawai, M. [2 ]
Gyobu, T. [3 ]
Kawata, Y. [4 ]
Johkoh, T.
Sekiguchi, J. [5 ]
Tomiyama, N. [1 ]
Yoshida, S. [1 ]
Sumikawa, H. [1 ]
Inoue, A. [1 ]
Yanagawa, M. [1 ]
Daimon, T. [1 ]
Nakamura, H. [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Radiol, Suita, Osaka 5650871, Japan
[2] Osaka Natl Hosp, Dept Radiol, Osaka, Japan
[3] Osaka Rosai Hosp, Dept Radiol, Osaka, Japan
[4] Osaka Med Ctr Canc & Cardiovasc Dis, Dept Diagnost Radiol, Osaka, Japan
[5] GE Healthcare Technol, CT Adv Applicat, Tokyo, Japan
关键词
MULTIDETECTOR-ROW CT; SMALL PULMONARY NODULES; AUTOMATED VOLUMETRY; VARIABILITY; MULTIPLANAR; ACCURACY;
D O I
10.1259/bjr/67746844
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate the reproducibility of volumetric software evaluation and manual evaluation of tumour growth. Three observers manually evaluated whether tumour volume was increasing, if it was unchanged, or if it had decreased in size in 2 serial CT examinations of 45 solid lung cancers. The tumour volumes were calculated 3 times using volumetric software and were evaluated using the same classifications as for manual evaluation. Both data sets were divided into three groups: growth or reduction with consistency among all three evaluations (group A), growth or reduction with consistency between only two evaluations (group B), and others (group C). The volume variation and relative volume variation were calculated from the median volumes measured by volumetric software. Although all 45 tumours were categorised in group A by volumetric software, only 21 tumours were categorised in group A by manual assessment. The relative volume variation of the manual assessment was 88.5 +/- 76.5%, 20.8 +/- 28.3% and 12.9 +/- 12.8% in group A, B and C, respectively. Significant differences were found between groups A and B (p<0.01) and between groups A and C (p<0.001). Inconsistency is often seen in manual assessment; in contrast, evaluation using volumetric software has good reproducibility, even when the relative change in tumour volume is small.
引用
收藏
页码:742 / 747
页数:6
相关论文
共 21 条
[1]   Volumetric assessment of pulmonary nodules with ECG-gated MDCT [J].
Boll, DT ;
Gilkeson, RC ;
Fleiter, TR ;
Blackham, KA ;
Duerk, JL ;
Lewin, JS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) :1217-1223
[2]   Interobserver-variability of lung nodule volumetry considering different segmentation algorithms and observer training levels [J].
Bolte, H. ;
Jahnke, T. ;
Schaefer, F. K. W. ;
Wenke, R. ;
Hoffmann, B. ;
Freitag-Wolf, S. ;
Dicken, V. ;
Kuhnigk, J. M. ;
Lohmann, J. ;
Voss, S. ;
Knoess, N. ;
Heller, M. ;
Biederer, J. .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 64 (02) :285-295
[3]   Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners [J].
Das, Marco ;
Ley-Zaporozhan, Julia ;
Gietema, H. A. ;
Czech, Andre ;
Muehlenbruch, Georg ;
Mahnken, Andreas H. ;
Katoh, Markus ;
Bakai, Annemarie ;
Salganicoff, Marcos ;
Diederich, Stefan ;
Prokop, Mathias ;
Kauczor, Hans-Ulrich ;
Guenther, Rolf W. ;
Wildberger, Joachim E. .
EUROPEAN RADIOLOGY, 2007, 17 (08) :1979-1984
[4]   Automated volumetry of solid pulmonary nodules in a phantom -: Accuracy across different CT scanner technologies [J].
Das, Marco ;
Muehlenbruch, Georg ;
Katoh, Markus ;
Bakai, Annemarie ;
Salganicoff, Marcos ;
Stanzel, Sven ;
Mahnken, Andreas H. ;
Guenther, Rolf W. ;
Wildberger, Joachim E. .
INVESTIGATIVE RADIOLOGY, 2007, 42 (05) :297-302
[5]   Volumetric measurements of lung nodules with multi-detector row CT: Effect of changes in lung volume [J].
Goo, Jin Mo ;
Kim, Kwang Gi ;
Gierada, David S. ;
Castro, Mario ;
Bae, Kyongtae T. .
KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (04) :243-248
[6]   Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy [J].
Goo, JM ;
Tongdee, T ;
Tongdee, R ;
Yeo, K ;
Hildebolt, CF ;
Bae, KT .
RADIOLOGY, 2005, 235 (03) :850-856
[7]   Thin-section multiplanar reformats from multidetector-row CT data: Utility for assessment of regional tumor extent in non-small cell lung cancer [J].
Higashino, T ;
Ohno, Y ;
Takenaka, D ;
Watanabe, H ;
Nogami, M ;
Ohbayashi, C ;
Yoshimura, M ;
Satouchi, M ;
Nishimura, Y ;
Fujii, M ;
Sugimura, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2005, 56 (01) :48-55
[8]   Computer-assisted lung nodule volumetry from multi-detector row CT: Influence of image reconstruction parameters [J].
Honda, Osamu ;
Sumikawa, Hiromitsu ;
Johkoh, Takeshi ;
Tomiyama, Noriyuki ;
Mihara, Naoki ;
Inoue, Atsuo ;
Tsubamoto, Mitsuko ;
Natsag, Javzandulam ;
Hamada, Seiki ;
Nakamura, Hironobu .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 62 (01) :106-113
[9]   Small pulmonary nodules: Volume measurement at chest CT - Phantom study [J].
Ko, JP ;
Rusinek, H ;
Jacobs, EL ;
Babb, JS ;
Betke, M ;
McGuinness, G ;
Naidich, DP .
RADIOLOGY, 2003, 228 (03) :864-870
[10]   Guidelines for management of small pulmonary nodules detected on CT scans: A statement from the Fleischner Society [J].
MacMahon, H ;
Austin, JHM ;
Gamsu, G ;
Herold, CJ ;
Jett, JR ;
Naidich, DP ;
Patz, EF ;
Swensen, SJ .
RADIOLOGY, 2005, 237 (02) :395-400