Pressed region integrated 3D paper-based microfluidic device that enables vertical flow multistep assays for the detection of C-reactive protein based on programmed reagent loading

被引:57
作者
Park, Juhwan [1 ]
Park, Je-Kyun [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, 291 Daehak Ro, Daejeon 34141, South Korea
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2017年 / 246卷
基金
新加坡国家研究基金会;
关键词
3D Paper-based microfluidics; C-Reactive protein; Pressed paper; Vertical flow assays; SANDWICH IMMUNOASSAY; ENZYME-IMMUNOASSAY; BIOSENSOR; SYSTEM;
D O I
10.1016/j.snb.2017.02.150
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although vertical flow assays (VFAs) have a number of advantages compared to lateral flow assays (LFAs) such as a short analysis time, no line interference, and no Hook effect, VFAs are not preferred as LFAs because of their complicated operation principle. In this study, we demonstrated VFAs with multistep reactions for the detection of C-reactive protein (CRP) based on the programmed reagent loading in a pressed region integrated 3D paper-based microfluidic device. The flow order of all reagents in a 3D paper-based microfluidic device was programmed based on the delayed flow caused by the pressed region as well as the geometry modification of the paper channel. After simultaneous loading of all the reagents required for assays, they are sequentially loaded into the analysis region with a programmed sequence. As a proof of concept, a high-sensitivity CRP (hs-CRP) detection with signal amplification was performed to predict the riskiness of cardiovascular disease within 15 min. The detection limit was improved from 0.01 to 0.005 mu g/mL via a maximum 3.47-fold signal amplification. Additionally, the upper limit of hs-CRP detection increased to 5 mu g/mL without Hook effect. Finally, we successfully detected hs-CRP in a clinically relevant range (0.005-5 mu g/mL), while LFAs cannot cover due to the Hook effect. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1049 / 1055
页数:7
相关论文
共 33 条
  • [1] Development of automated paper-based devices for sequential multistep sandwich enzyme-linked immunosorbent assays using inkjet printing
    Apilux, Amara
    Ukita, Yoshiaki
    Chikae, Miyuki
    Chailapakul, Orawon
    Takamura, Yuzuru
    [J]. LAB ON A CHIP, 2013, 13 (01) : 126 - 135
  • [2] Procalcitonin and C-reactive protein during systemic inflammatory response syndrome, sepsis and organ dysfunction
    Castelli, GP
    Pognani, C
    Meisner, M
    Stuani, A
    Bellomi, D
    Sgarbi, L
    [J]. CRITICAL CARE, 2004, 8 (04): : R234 - R242
  • [3] Comparison of differing C-reactive protein assay methods and their impact on cardiovascular risk assessment
    Clarke, JL
    Anderson, JL
    Carlquist, JF
    Roberts, RF
    Horne, BD
    Bair, TL
    Kolek, MJ
    Mower, CP
    Crane, AM
    Roberts, WL
    Muhlestein, JB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (01) : 155 - 158
  • [4] Measurement of C-reactive protein: Two high sensitivity methods compared
    Dominici, R
    Luraschi, P
    Franzini, C
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2004, 18 (05) : 280 - 284
  • [5] FERNANDO SA, 1992, J IMMUNOL METHODS, V151, P47
  • [6] Two-Dimensional Paper Network Format That Enables Simple Multistep Assays for Use in Low-Resource Settings in the Context of Malaria Antigen Detection
    Fu, Elain
    Liang, Tinny
    Spicar-Mihalic, Paolo
    Houghtaling, Jared
    Ramachandran, Sujatha
    Yager, Paul
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (10) : 4574 - 4579
  • [7] 3D Origami-based multifunction-integrated immunodevice: low-cost and multiplexed sandwich chemiluminescence immunoassay on microfluidic paper-based analytical device
    Ge, Lei
    Wang, Shoumei
    Song, Xianrang
    Ge, Shenguang
    Yu, Jinghua
    [J]. LAB ON A CHIP, 2012, 12 (17) : 3150 - 3158
  • [8] Highly Sensitive Two-Dimensional Paper Network Incorporating Biotin Streptavidin for the Detection of Malaria
    Grant, Benjamin D.
    Smith, Chelsey A.
    Karvonen, Kristine
    Richards-Kortum, Rebecca
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (05) : 2553 - 2557
  • [9] Label-free detection of C-reactive protein using a carbon nanofiber based biosensor
    Gupta, Rakesh K.
    Periyakaruppan, Adaikkappan
    Meyyappan, M.
    Koehne, Jessica E.
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 59 : 112 - 119
  • [10] Three-dimensional paper-based slip device for one-step point-of-care testing
    Han, Kwi Nam
    Choi, Jong-Soon
    Kwon, Joseph
    [J]. SCIENTIFIC REPORTS, 2016, 6