Design and fabrication of a graphene-based microcantilever flow sensor for liquid flow measurement

被引:17
|
作者
Shadmand, Zahra [1 ]
Shahrouzi, Javad Rahbar [1 ]
Chaboki, Hossein Hosseinzadeh [1 ]
机构
[1] Sahand Univ Technol, Fac Chem Engn, Sahand New Town, Tabriz, Iran
关键词
Flowmeter; Cantilever; Flow sensor; Piezoresistive; Graphene oxide; PIEZORESISTIVE SENSOR; PRESSURE SENSOR; NETWORK;
D O I
10.1016/j.sna.2020.112438
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a piezoresistive cantilever flow sensor was fabricated to measure the velocity of water flow in the operating range of 0 to 0.7 m/s, and the influence of the operating parameters on its performance were investigated. Prior to fabrication, a computer simulation was performed to design the specification and dimension of the flowmeter and obtain the appropriate operating conditions. To fabricate a cantilever beam graphene oxide (GO), as a piezoresistive material, was coated on a polyester substrate. Then it was reduced at 130 degrees C to create semiconducting properties in the GO film. Polyvinylidene fluoride (PVDF) was dip-coated on the piezoresistive GO layer to create a waterproof and protective coating. Then, the performance of the cantilever flowmeter was determined by measuring the resistance change in different water velocities. Moreover, the bending angle of the cantilever was obtained by taking photos of the beam deflection, followed by image processing. The results revealed that the calibration curve was successfully performed by regression of output signal versus flow velocity with 2nd-order polynomial function (R-2 = 0.998). Furthermore, the overall system accuracy was reached up to +/- 3.2 % full scale. The sensitivity of the sensor in the measuring range was equal to 1.22 Omega / (m.s(-1)), and the response time of the system was measured to be less than 5 s. Ultimately, experimental data demonstrated good accordance with the simulation studies. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Flow control system design without flow meter sensor
    Choi, Jeongju
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 185 : 127 - 131
  • [32] Electromechanical Piezoresistive Sensing of Graphene-based Intracranial Pressure Sensor
    Mohamad, M.
    Soin, N.
    Ibrahim, F.
    2018 IEEE 8TH INTERNATIONAL NANOELECTRONICS CONFERENCES (INEC), 2018, : 25 - 26
  • [33] Simulation study of nano aqueous flow sensor based on amperometric measurement
    Wu, Jian
    Zhou, Qingli
    Liu, Jun
    Lou, Zhengguo
    SENSORS, 2006, 6 (05): : 473 - 479
  • [34] A silicon rectangular micro-orifice for gas flow measurement at moderate Reynolds numbers: design, fabrication and flow analyses
    A. Amnache
    M. Omri
    L. G. Fréchette
    Microfluidics and Nanofluidics, 2018, 22
  • [35] Design and TEM simulation of a MEMS based microcantilever cardiac marker sensor
    Vidhya S.
    Kumar G.P.
    Mathew L.
    Journal of Nanotechnology in Engineering and Medicine, 2010, 1 (01)
  • [36] A new type of velocity averaging tube vortex flow sensor and measurement model of mass flow rate
    Fang, Lide
    Liu, Yueyuan
    Zheng, Meng
    Liu, Xu
    Lan, Kang
    Wang, Fan
    Yan, Xiaoli
    ENERGY, 2023, 283
  • [37] Graphene-Based Light Sensing: Fabrication, Characterisation, Physical Properties and Performance
    De Sanctis, Adolfo
    Mehew, Jake D.
    Craciun, Monica F.
    Russo, Saverio
    MATERIALS, 2018, 11 (09)
  • [38] Research on Liquid Flow Measurement Method Based on Heat Transfer Method
    Qin, Hongwei
    Dang, Ruirong
    Dang, Bo
    WATER, 2023, 15 (06)
  • [39] Impedance based flow sensor
    Green, NG
    Tao, S
    Holmes, D
    Morgan, H
    Smart Sensors, Actuators, and MEMS II, 2005, 5836 : 634 - 641
  • [40] Measurement and simulation of the frequency response of a thermal flow sensor at different flow speeds
    Reyes-Romero, D. F.
    Cubukcu, A. S.
    Urban, G. A.
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 189 : 168 - 176