Design and fabrication of a graphene-based microcantilever flow sensor for liquid flow measurement

被引:17
|
作者
Shadmand, Zahra [1 ]
Shahrouzi, Javad Rahbar [1 ]
Chaboki, Hossein Hosseinzadeh [1 ]
机构
[1] Sahand Univ Technol, Fac Chem Engn, Sahand New Town, Tabriz, Iran
关键词
Flowmeter; Cantilever; Flow sensor; Piezoresistive; Graphene oxide; PIEZORESISTIVE SENSOR; PRESSURE SENSOR; NETWORK;
D O I
10.1016/j.sna.2020.112438
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a piezoresistive cantilever flow sensor was fabricated to measure the velocity of water flow in the operating range of 0 to 0.7 m/s, and the influence of the operating parameters on its performance were investigated. Prior to fabrication, a computer simulation was performed to design the specification and dimension of the flowmeter and obtain the appropriate operating conditions. To fabricate a cantilever beam graphene oxide (GO), as a piezoresistive material, was coated on a polyester substrate. Then it was reduced at 130 degrees C to create semiconducting properties in the GO film. Polyvinylidene fluoride (PVDF) was dip-coated on the piezoresistive GO layer to create a waterproof and protective coating. Then, the performance of the cantilever flowmeter was determined by measuring the resistance change in different water velocities. Moreover, the bending angle of the cantilever was obtained by taking photos of the beam deflection, followed by image processing. The results revealed that the calibration curve was successfully performed by regression of output signal versus flow velocity with 2nd-order polynomial function (R-2 = 0.998). Furthermore, the overall system accuracy was reached up to +/- 3.2 % full scale. The sensitivity of the sensor in the measuring range was equal to 1.22 Omega / (m.s(-1)), and the response time of the system was measured to be less than 5 s. Ultimately, experimental data demonstrated good accordance with the simulation studies. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Design and Modeling of a New MEMS Capacitive Microcantilever Sensor for Gas Flow Monitoring
    Panahi, Abbas
    Ghasemi, Pouya
    Sabour, Mohammad Hossein
    Magierowski, Sebastian
    Ghafar-Zadeh, Ebrahim
    IEEE CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2021, 44 (04): : 467 - 479
  • [2] A self-bended piezoresistive microcantilever flow sensor for low flow rate measurement
    Zhang, Qi
    Ruan, Wenzhou
    Wang, Han
    Zhou, Youzheng
    Wang, Zheyao
    Liu, Litan
    SENSORS AND ACTUATORS A-PHYSICAL, 2010, 158 (02) : 273 - 279
  • [3] Fabrication and evaluation of a graphene oxide-based cantilever-type flow-meter for subsonic gas flow rate measurement
    Hamdollahi, Hassan
    Rahbar-Shahrouzi, Javad
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (05)
  • [4] A microcantilever-based gas flow sensor for flow rate and direction detection
    Rong-Hua Ma
    Po-Cheng Chou
    Yu-Hsiang Wang
    Tzu-Han Hsueh
    Lung-Ming Fu
    Chia-Yen Lee
    Microsystem Technologies, 2009, 15 : 1201 - 1205
  • [5] Self-oscillating microcantilever piezoresistive flow sensor
    Go, Jeung Sang
    Shin, Bosung
    Ko, Jong Soo
    Experimental Mechanics in Nano and Biotechnology, Pts 1 and 2, 2006, 326-328 : 1347 - 1350
  • [6] Design and Fabrication of a MEMS Flow Sensor and Its Application in Precise Liquid Dispensing
    Liu, Yaxin
    Chen, Liguo
    Sun, Lining
    SENSORS, 2009, 9 (06) : 4138 - 4150
  • [7] Design, Simulation and Fabrication of A Micromachined Cantilever-based Flow Sensor
    Chen, Pei
    Zhao, Yulong
    Li, Yiyao
    2013 8TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (IEEE NEMS 2013), 2013, : 681 - 684
  • [8] PDMS Microcantilever-Based Flow Sensor Integration for Lab-on-a-Chip
    Nezhad, Amir Sanati
    Ghanbari, Mahmood
    Agudelo, Carlos G.
    Packirisamy, Muthukumaran
    Bhat, Rama B.
    Geitmann, Anja
    IEEE SENSORS JOURNAL, 2013, 13 (02) : 601 - 609
  • [9] Design and simulation of a thermo transfer type MEMS based micro flow sensor for arterial blood flow measurement
    Kalyan Kumar Mistry
    Abhijit Mahapatra
    Microsystem Technologies, 2012, 18 : 683 - 692
  • [10] Design and analysis of MEMS piezoresistive rectangular paddle microcantilever based wind speed sensor
    Agrawal, Vimal Kumar
    Patel, Raju
    Boolchandani, Dharmendar
    Rangra, Kamal J.
    INTEGRATED FERROELECTRICS, 2018, 193 (01) : 43 - 58