Vacuum-assisted headspace-solid phase microextraction for determining volatile free fatty acids and phenols. Investigations on the effect of pressure on competitive adsorption phenomena in a multicomponent system

被引:52
作者
Trujillo-Rodriguez, Maria J. [1 ]
Pino, Veronica [1 ]
Psillakis, Elefteria [2 ]
Anderson, Jared L. [3 ]
Ayala, Juan H. [1 ]
Yiantzi, Evangelia [2 ]
Afonso, Ana M. [1 ]
机构
[1] Univ La Laguna, Dept Quim, Unidad Dept Quim Analit, E-38206 Tenerife, Spain
[2] Tech Univ Crete, Lab Aquat Chem, Sch Environm Engn, Polytecheioupolis, GR-73100 Khania, Crete, Greece
[3] Iowa State Univ, Dept Chem, Ames, IA 50011 USA
基金
美国国家科学基金会;
关键词
Headspace solid-phase microextraction; Vacuum-assisted headspace solid-phase microextraction; Gas chromatography; Volatile free fatty acids; Phenols; Milk samples; LIQUID SORBENT COATINGS; OF-THE-ART; POLYCYCLIC AROMATIC-HYDROCARBONS; CHROMATOGRAPHY-MASS-SPECTROMETRY; GAS-CHROMATOGRAPHY; IONIC LIQUIDS; EXTRACTION; FIBER; WATER; CHEESES;
D O I
10.1016/j.aca.2017.01.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work proposes a new vacuum headspace solid-phase microextraction (Vac-HSSPME) method combined to gas chromatography-flame ionization detection for the determination of free fatty acids (FFAs) and phenols. All target analytes of the multicomponent solution were volatiles but their low Henry's Law constants rendered them amenable to Vac-HSSPME. The ability of a new and easy to construct Vac-HSSPME sampler to maintain low-pressure conditions for extended sampling times was concurrently demonstrated. Vac-HSSPME and, regular HSSPME methods were independently optimized and the results were compared at all times. The performances of four commercial SPME fibers and two polymeric ionic liquid (PIL)-based SPME fibers were evaluated and the best overall results were obtained with the adsorbent-type CAR/PDMS fiber. For the concentrations used here, competitive displacement became more intense for the smaller and more volatile analytes of the multi-component solution when lowering the sampling pressure. The extraction time profiles showed that Vac-HSSPME had a dramatic positive effect on extraction kinetics. The local maxima of adsorbed analytes recorded with Vac-HSSPME occurred faster, but were always lower than that with regular HSSPME due to the faster analyte-loading from the multicomponent solution. Increasing the sampling temperature during Vac-HSSPME reduced the extraction efficiency of smaller analytes due to the enhancement in water molecule collisions with the fiber. This effect was not recorded for the larger phenolic compounds. Based on the optimum values selected, Vac-HSSPME required a shorter extraction time and milder sampling conditions than regular HSSPME: 20 min and 35 degrees C for Vac-HSSPME versus 40 min and 45 C for regular HSSPME. The performance of the optimized Vac-HSSPME and regular HSSPME procedures were assessed and Vac-HSSPME method proved to be more sensitive, with lower limits of detection (from 0.14 to 13 mu g L-1), and better intra-day precision (relative standard deviations values < 10% at the lowest spiked level) than regular HSSPME for almost all target analytes. The proposed Vac-HSSPME method was successfully applied to quantify FFAs and phenols in milk and milk derivatives samples. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 51
页数:11
相关论文
共 40 条
  • [11] New approach of solid-phase microextraction improving the extraction yield of butyl and phenyltin compounds by combining the effects of pressure and type of agitation
    Darrouzès, J
    Bueno, M
    Pécheyran, C
    Holeman, M
    Potin-Gautier, M
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1072 (01) : 19 - 27
  • [12] A salting out system for improving the efficiency of the headspace solid-phase microextraction of short and medium chain free fatty acids
    Fiorini, Dennis
    Pacetti, Deborah
    Gabbianelli, Rosita
    Gabrielli, Serena
    Ballini, Roberto
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1409 : 282 - 287
  • [13] Headspace versus Direct Immersion Solid Phase Microextraction in Complex Matrixes: Investigation of Analyte Behavior in Multicomponent Mixtures
    Gionfriddo, Emanuela
    Souza-Silva, Erica A.
    Pawliszyn, Janusz
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (16) : 8448 - 8456
  • [14] Glykioti ML, 2016, ANAL METHODS-UK, V8, P8065, DOI [10.1039/c6ay02210c, 10.1039/C6AY02210C]
  • [15] Theory of analyte extraction by selected porous polymer SPME fibres
    Górecki, T
    Yu, XM
    Pawliszyn, J
    [J]. ANALYST, 1999, 124 (05) : 643 - 649
  • [16] Recovery of phosphonate surface contaminants from glass using a simple vacuum extractor with a solid-phase microextraction fiber
    Groenewold, Gary S.
    Scott, Jill R.
    Rae, Catherine
    [J]. ANALYTICA CHIMICA ACTA, 2011, 697 (1-2) : 38 - 47
  • [17] Insight into the extraction mechanism of polymeric ionic liquid sorbent coatings in solid-phase microextraction
    Ho, Tien D.
    Cole, William T. S.
    Augusto, Fabio
    Anderson, Jared L.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1298 : 146 - 151
  • [18] Joshi MD, 2014, TALANTA, V118, P172, DOI [10.1016/j.talanta.2013.10.01, 10.1016/j.talanta.2013.10.014]
  • [19] Air sampling with porous solid-phase microextraction fibers
    Koziel, J
    Jia, MY
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5178 - 5186
  • [20] Development of a reduced pressure headspace solid-phase microextraction-gas chromatography/mass spectrometric (rpHSSPME-GC/MS) method and application to aroma analysis
    Lee, Changgook
    Lee, Younghoon
    Lee, Jae-Gon
    Buglass, Alan J.
    [J]. ANALYTICAL METHODS, 2015, 7 (16) : 6504 - 6513