Clinical evaluation of the repeatability of ocular aberrometry obtained with a new pyramid wavefront sensor

被引:18
作者
Plaza-Puche, Ana B. [1 ]
Salerno, Liberdade C. [1 ]
Versaci, Francesco [2 ]
Romero, Daniel [3 ]
Alio, Jorge L. [1 ,3 ]
机构
[1] Vissum, Avda Denia S-N,Edificio Vissum, Alicante 03016, Spain
[2] CSO, R&D Dept, Florence, Italy
[3] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
关键词
Ocular aberrometry; pyramidal aberrometer; intrasubject repeatability; IN-SITU KERATOMILEUSIS; HARTMANN-SHACK ABERROMETER; ADAPTIVE OPTICS; ABERRATIONS; PRINCIPLES; PRECISION; QUALITY; EYE;
D O I
10.1177/1120672118816060
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the intrasubject repeatability of the ocular aberrometry obtained with a new ocular pyramidal aberrometer technology in a sample of normal eyes. Methods: A total of 53 healthy eyes of 53 subjects with ages ranging from 18 to 45 years were included in this study. In all cases, three consecutive acquisitions were obtained. Intrasubject repeatability of the measurements with a pyramidal aberrometer was calculated. Intrasubject repeatability for 4.0- and 6.0-mm pupils was evaluated within the subject standard deviation (S-w) and intraclass correlation coefficient. Results: Low values of the S-w and intraclass correlation coefficient outcomes close to 1 were observed for the sphere and cylinder at 3.0-mm pupil size. Most low S-w and intraclass correlation coefficient values close to 1 were observed for total, low-order aberrations and higher-order aberrations root mean square and for each Zernike coefficient analysis (intraclass correlation coefficient > 0.798) at 4.0-mm pupil size, with more limited outcomes for the aberrometric coefficient of Z(4, 4) with an intraclass correlation coefficient of 0.683. For a 6.0 mm pupil diameter, low S-w and intraclass correlation coefficient values close to 1 were observed for all aberrometric parameters or Zernike coefficients analyzed (intraclass correlation coefficient > 0.850). Conclusion: The new pyramidal aberrometer Osiris provides repeatable and consistent measurements of ocular aberrometry measurements in normal eyes.
引用
收藏
页码:585 / 592
页数:8
相关论文
共 35 条
[1]   Corneal wavefront-guided photorefractive keratectomy in patients with irregular corneas after corneal refractive surgery [J].
Alio, Jorge L. ;
Pinero, David P. ;
Belen Plaza, Ana .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (10) :1727-1735
[2]   Corneal aberrations and objective visual quality after hyperopic laser in situ keratomileusis using the Esiris excimer laser [J].
Alio, Jorge L. ;
Pinero, David P. ;
Ayala Espinosa, Maria Jose ;
Jose Garcia, Maria .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03) :398-406
[3]   Precision of higher order aberration repeatability with NIDEK OPD-Scan retinoscopic aberrometry [J].
Barreto, Jackson, Jr. ;
Netto, Marcelo V. ;
Cigna, Alberto ;
Bechara, Samir ;
Kara-Jose, Newton .
JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (09) :S1037-S1040
[4]   Measurement error and correlation coefficients [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7048) :41-42
[5]  
Bland JM, 1996, BRIT MED J, V313, P744
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]  
Carkeet A, 2003, J REFRACT SURG, V19, P316
[8]   Clinical ocular wavefront analyzers [J].
Cervino, Alejandro ;
Hosking, Sarah L. ;
Montes-Mico, RoberL ;
Bates, Keith .
JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (06) :603-616
[9]   Adaptive optics for ophthalmic applications using a pyramid wavefront sensor [J].
Chamot, SR ;
Dainty, C ;
Esposito, S .
OPTICS EXPRESS, 2006, 14 (02) :518-526
[10]   Problems in the measurement of wavefront aberration for eyes implanted with diffractive bifocal and multifocal intralocular lenses [J].
Charman, W. Neil ;
Montes-Mico, Robert ;
Radhakrishnan, Hema .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) :280-286