Quality improvement initiative for reduction of false alarms from multiparameter monitors in neonatal intensive care unit

被引:7
作者
Sahoo, Tanushree [1 ]
Joshi, Meena [1 ]
Madathil, Shamnad [1 ]
Verma, Ankit [1 ]
Sankar, Mari Jeeva [1 ]
Thukral, Anu [1 ]
机构
[1] All India Inst Med Sci, Dept Pediat, Div Neonatol, New Delhi, India
关键词
False alarms; multiparameter monitors; quality improvement initiative;
D O I
10.4103/jehp.jehp_226_19
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
INTRODUCTION: Unnecessary and excessive activation of alarms ("false alarm") in neonatal intensive care unit (NICU) often results in alarm fatigue among health-care professionals, which can potentially result in deleterious effects in sick neonates. AIMS AND OBJECTIVES: The aim of this study is to reduce the frequency of false alarms from multiparameter monitors (MPM) by 50% from the existing baseline level over a period of 12 weeks. METHODS: In this quality improvement (QI) project conducted over 1 year (November 2016-October 2017) at All India Institute of Medical Sciences, New Delhi, we collected data on activation of false alarms from MPM (outcome measure) over a period of 2 months in 134 randomly selected observations of 1-h duration (baseline phase [10 days, 20 observations] and developing and testing the changes in five Plan-Do-study-Act (PDSA) cycles over the next 50 days, 114 observations. We also measured the pre- and postassessment of knowledge level in use of MPM among health-care professionals using checklist (process measure). Following that, we continued data collection for next 10 months to check sustenance of the project. RESULTS: Baseline characteristics including gestation, birth weight, and sickness level did not vary during the study period. The median (range) number of activation of false alarms/hour/MPM was 23 (18-35) in the baseline phase. This reduced to 22 (17-30), 19 (15-30), 16 (14-30), 14 (8-17), and 9 (6-12) at the end of 1st, 2nd, 3rd, 4th, and 5th PDSA cycles, respectively. In sustenance phase, it could be maintained in target range from January 2017 to October 2017. CONCLUSIONS: Small sustained changes can contribute a lot in continuous QI in decreasing false alarms and subsequent improvement of neurodevelopmental outcomes discharged neonates.
引用
收藏
页数:7
相关论文
共 19 条
  • [1] [Anonymous], 2013, Jt Comm Perspect, V33, P3
  • [2] ALARMED: Adverse events in low-risk patients with chest pain receiving continuous electrocardiographic monitoring in the Emergency Department. A pilot study
    Atzema, C
    Schull, MJ
    Borgundvaag, B
    Slaughter, GRD
    Lee, CK
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2006, 24 (01) : 62 - 67
  • [3] Bitan Y., 2004, COGN TECHNOL WORK, V6, P239, DOI DOI 10.1007/S10111-004-0162-2
  • [4] BRIEF E, 2016, TOP 10 HLTH TECHN HA
  • [5] BRIEF E, TOP 10 HLTH TECHN HA
  • [6] A targeted noise reduction observational study for reducing noise in a neonatal intensive unit
    Chawla, S.
    Barach, P.
    Dwaihy, M.
    Kamat, D.
    Shankaran, S.
    Panaitescu, B.
    Wang, B.
    Natarajan, G.
    [J]. JOURNAL OF PERINATOLOGY, 2017, 37 (09) : 1060 - 1064
  • [7] Practice standards for electrocardiographic monitoring in hospital settings - An American Heart Association Scientific Statement from the councils on cardiovascular nursing, clinical cardiology, and cardiovascular disease in the young
    Drew, BJ
    Califf, RM
    Funk, M
    Kaufman, ES
    Krucoff, MW
    Laks, MM
    Macfarlane, PW
    Sommargren, C
    Swiryn, S
    Van Hare, GF
    [J]. CIRCULATION, 2004, 110 (17) : 2721 - 2746
  • [8] Implementation of Data Driven Heart Rate and Respiratory Rate Parameters on a Pediatric Acute Care Unit
    Goel, Veena
    Poole, Sarah
    Kipps, Alaina
    Palma, Jonathan
    Platchek, Terry
    Pageler, Natalie
    Longhusrt, Christopher
    Sharek, Paul
    [J]. MEDINFO 2015: EHEALTH-ENABLED HEALTH, 2015, 216 : 918 - 918
  • [9] MONITOR ALARM FATIGUE: STANDARDIZING USE OF PHYSIOLOGICAL MONITORS AND DECREASING NUISANCE ALARMS
    Graham, Kelly Creighton
    Cvach, Maria
    [J]. AMERICAN JOURNAL OF CRITICAL CARE, 2010, 19 (01) : 28 - 34
  • [10] Reducing Alarm Fatigue in Two Neonatal Intensive Care Units through a Quality Improvement Collaboration
    Johnson, Kendall R.
    Hagadorn, James I.
    Sink, David W.
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 2018, 35 (13) : 1311 - 1318