A low-noise charge amplifier with fast rise time and active discharge mechanism

被引:14
作者
Bassini, R
Boiano, C
Pullia, A
机构
[1] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[2] Univ Milan, Dept Phys, I-20133 Milan, Italy
关键词
charge amplifier; low-noise amplifier; X-ray spectroscopy;
D O I
10.1109/TNS.2002.803865
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new hybrid, low-noise, wide-bandwidth charge amplifier, using a new active discharge mechanism, has been designed and built primarily for gamma-ray tracking detectors, where a fast rise time is required. In order to realize the discharge of the feedback capacitance, a noninverting low-gain (A) stage has been inserted between the output of a conventional charge preamplifier and the high-value feedback resistance. This technique allows to make the discharge time constant shorter (by factor A), while keeping the feedback resistor as the feedback capacitance unchanged. Special care has been devoted realizing the hybrid layout to reduce the stray capacitance of the feedback resistor and particular attention has been dedicated to assure a good signal-to-noise ratio and a fast rise time. A low-power consumption allows the use of this charge-sensitive preamplifier in vacuum chamber without cooling system. The noise level is equivalent to less than 880-eV full width half maximum for an input capacitance of 22 pF, using 3-mus shaping time. The noise grows with a slope of less than 10 eV/pF in the range of 20-60 pF input capacitance. This suggests that the preamplifier can be operated at room temperature maintaining a good noise usually reachable with a cooled setup.
引用
收藏
页码:2436 / 2439
页数:4
相关论文
共 6 条
  • [1] Analysis of simulated and measured pulse shapes of closed-ended HPGe detectors
    Kroll, T
    Peter, I
    Elze, TW
    Gerl, J
    Happ, T
    Kaspar, M
    Schaffner, H
    Schremmer, S
    Schubert, R
    Vetter, K
    Wollersheim, HJ
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 371 (03) : 489 - 496
  • [2] Simulation and analysis of pulse shapes from highly segmented HPGe detectors for the γ-ray tracking array MARS
    Kröll, T
    Bazzacco, D
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 463 (1-2) : 227 - 249
  • [3] *PHIL SEM, 2000, DISCR SEM DAT SHEET
  • [4] A "Cold" discharge mechanism for low-noise fast charge amplifiers
    Pullia, A
    Bassini, R
    Boiano, C
    Brambilla, S
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 530 - 534
  • [5] Efficiency of segmented HPGe detectors: Design criteria for pulse shape analysis
    Wieland, O
    Camera, F
    Million, B
    Bracco, A
    Pignanelli, M
    Ripamonti, G
    Geraci, A
    Van der Marel, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 296 - 301
  • [6] EURISYS MESURES