A method to alleviate false-positive results of the Elecsys HIV combi PT assay

被引:2
作者
Lu, Xiaolan [1 ,2 ,3 ]
Zhang, Minghong [4 ]
Liu, Wen [1 ,2 ,3 ]
Sheng, Nan [4 ]
Du, Qin [1 ,2 ,3 ]
Zhang, Maoxin [1 ]
Guo, Xiaolan [1 ,2 ,3 ]
Wang, Guangrong [1 ,2 ,3 ]
Wang, Qiang [1 ,2 ,3 ]
机构
[1] North Sichuan Med Coll, Affiliated Hosp, Dept Lab Med, Nanchong, Sichuan, Peoples R China
[2] North Sichuan Med Coll, Coll Lab Med, Nanchong, Sichuan, Peoples R China
[3] North Sichuan Med Coll, Fac Lab Med, Ctr Translat Med, Nanchong, Sichuan, Peoples R China
[4] Nanchong Ctr Dis Control & Prevent, Nanchong, Sichuan, Peoples R China
关键词
P24; ANTIGEN; PREVALENCE; INFECTION;
D O I
10.1038/s41598-020-80047-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To explore the effects of urea dissociation on reducing false-positive results of the Elecsys HIV combi PT assay. A retrospective analysis was used to evaluate the false-positive rate of the Elecsys HIV combi PT assay. Six false-positive sera, six positive sera and six sera from patients with early HIV infection were collected. Dissociation was performed using 1 mol/L, 2 mol/L, 4 mol/L, 6 mol/L, or 8 mol/L urea, and HIV screening assay were then detected to select the appropriate concentration of urea dissociation. Next, 55 false-positive sera and 15 sera from early HIV infection were used to verify the best concentration of urea to achieve dissociation. Retrospective analysis showed that the COI of the Elecsys HIV combi PT assay in false-positive sera ranged from 1.0 to 200.0, and approximately 97.01%(227/234) of false-positive sera were in the range of 1.0-15.0. The avidity index (AI) in positive and false-positive sera decreased as the urea dissociation concentration increased. When the dissociation concentration was 6 mol/L, the AI of false-positive serum was between 0.0234 and 0.2567, and the AI of early HIV infection sera was between 0.4325 and 0.5017. The difference in AI between false-positive and positive samples was significant. When negativity was defined as an AI of less than 0.3970, the sensitivity and specificity were 100.0% and 100.0%, respectively. Urea-mediated dissociation could significantly reduce the false-positive rate of the Elecsys HIV combi PT assay with a low COI. Our findings provided a reference for distinguishing positive and false-positive of the Elecsys HIV combi PT assay.
引用
收藏
页数:9
相关论文
共 30 条
  • [1] Evaluation of the Architect HIV Ag/Ab Combo Assay in a low-prevalence setting: The role of samples with a low S/CO ratio
    Alonso, Roberto
    Perez-Garcia, Felipe
    Gijon, Paloma
    Collazos, Ana
    Bouza, Emilio
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2018, 103 : 43 - 47
  • [2] Comparative Performance of Electrochemiluminescence Immunoassay and EIA for HIV Screening in a Multiethnic Region of China
    Bi, Xiaohui
    Ning, Hongxia
    Wang, Tingting
    Li, Dongdong
    Liu, Yongming
    Yang, Tingfu
    Yu, Jiansheng
    Tao, Chuanmin
    [J]. PLOS ONE, 2012, 7 (10):
  • [3] Comparison of electrochemiluminescence and ELISA methods in the detection of blood borne pathogens in Gabon
    Bisseye, Cyrille
    Ndong, Jophrette Mireille Ntsame
    Matoumba, Anicet Mouity
    Bengone, Calixte
    Migolet, Guy Mouelet
    Nagalo, Bolni Marius
    [J]. ASIAN PACIFIC JOURNAL OF TROPICAL BIOMEDICINE, 2017, 7 (09) : 805 - 808
  • [4] Sensitivity of the STAT-VIEW rapid self-test and implications for use during acute HIV infection
    Boukli, Narjis
    Boyd, Anders
    Wendremaire, Noemie
    Girard, Pierre-Marie
    Bottero, Julie
    Morand-Joubert, Laurence
    [J]. SEXUALLY TRANSMITTED INFECTIONS, 2018, 94 (07) : 475 - 478
  • [5] Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test
    Brust, S
    Duttmann, H
    Feldner, J
    Gürtler, L
    Thorstensson, R
    Simon, F
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2000, 90 (02) : 153 - 165
  • [6] Cheng M, 2016, MOD HOSP, V01, P30
  • [7] Dong WB., 2017, MOD PREVENT MED, V44, P1879
  • [8] Ekaterine K., 2019, J MED VIROL, V91, P235, DOI [10.1002/jmv.25245, DOI 10.1002/JMV.25245]
  • [9] FORSTER SM, 1987, AIDS, V1, P235
  • [10] Factors associated with a second deferral among donors eligible for re-entry after a false-positive screening test for syphilis, HCV, HBV and HIV
    Gregoire, Y.
    Germain, M.
    Delage, G.
    [J]. VOX SANGUINIS, 2018, 113 (04) : 339 - 344