Conductive keratoplasty for the correction of low to moderate hyperopia: US clinical trial 1-year results on 355 eyes

被引:69
作者
McDonald, MB
Hersh, PS
Manche, EE
Maloney, RK
Davidorf, J
Sabry, M
机构
[1] So Vis Inst, New Orleans, LA 70115 USA
[2] Cornea & Laser Vis Ctr, Teaneck, NJ USA
[3] Stanford Univ, Sch Med, Palo Alto, CA 94304 USA
[4] Maloney Vis Inst, Los Angeles, CA USA
[5] Davidorf Eye Grp, Canoga Pk, CA USA
关键词
D O I
10.1016/S0161-6420(02)01255-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To document the 1-year safety, efficacy, and stability results of 355 eyes treated in the multicenter study of conductive keratoplasty (GK) used to correct low to moderate hyperopia. Design: Nonrandomized comparative (self-controlled) trial. Participants: Twenty surgeons at 13 centers performed CK on the eyes of all patients enrolled in a multicenter, 2-year, U.S. phase III clinical trial. Treated eyes had +0.75 to +3.00 diopters (D) of hyperopia and less than or equal to0.75 D of cylinder. Patients were 40 years of age or older. Intervention: Low-energy, high-frequency current was applied directly into the peripheral corneal stroma through a delivery tip inserted at 8 to 32 treatment spots. The number of treatment spots was increased for increasing levels of hyperopia, but the amount of radiofrequency energy remained constant. Emmetropia was intended. All eyes were treated once (there were no retreatments). Main Outcome Measures: Data from 355 eyes with 1 year of follow-up were analyzed for safety and stability, and data from 318 eyes were analyzed for efficacy and predictability, as well as stability and safety. All patients reported on satisfaction and quality of vision after surgery. Results: At 1 year, uncorrected visual acuity was less than or equal to20/20 in 56%, less than or equal to20/25 in 75%, and <20/40 in 92% of eyes. The manifest refractive spherical equivalent refraction was within 0.50 D in 63%, within +/-1.00 D in 89%, and within +/-2.00 D in 99%. Seven of 355 eyes lost 2 lines of best spectacle-corrected visual acuity at 1 year, but no eye lost >2 lines. One eye of 355 had induced cylinder of >2.00 D. The cycloplegic refractive spherical equivalent changed a mean of 0.25 +/- 0.50 D between months 3 and 6, 0.11 +/- 0.41 D between months 6 and 9, and 0.11 +/- 0.35 D between months 9 and 12. Refractive stability seemed to be attained by 6 months and remained stable through 12 months. Histology and confocal microscopy showed deep penetration of the treatment into the stroma. Endothelial cell counts were not changed by the treatment. Conclusions: CK seems to be safe, effective, and stable for correcting low to moderate spherical hyperopia in patients 40 years old or older. Treatment penetration is deep and cylindrical in shape, and it does not damage the corneal endothelium. Uncorrected visual acuity, predictability, and stability are as good as or better than those obtained with other techniques used to correct hyperopia. (C) 2002 by the American Academy of Ophthalmology, Inc.
引用
收藏
页码:1978 / 1989
页数:12
相关论文
共 33 条
[1]  
Alio JL, 1997, J REFRACT SURG, V13, P17
[2]   Laser in situ keratomileusis for hyperopia [J].
Argento, CJ ;
Cosentino, MJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (08) :1050-1058
[3]  
Bende T, 1999, J REFRACT SURG, V15, P154
[4]   Influence of temperature and time on thermally induced forces in corneal collagen and the effect on laser thermokeratoplasty [J].
Brinkmann, R ;
Radt, B ;
Flamm, C ;
Kampmeier, J ;
Koop, N ;
Birngruber, R .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (05) :744-754
[5]  
CHARPENTIER DY, 1995, J FR OPHTALMOL, V18, P200
[6]   Excimer laser photorefractive keratectomy for hyperopia [J].
Dausch, D ;
Smecka, Z ;
Klein, R ;
Schroder, E ;
Kirchner, S .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (02) :169-176
[7]   Effect of varying the optical zone diameter on the results of hyperopic laser in situ keratomileusis [J].
Davidorf, JM ;
Eghbali, F ;
Onclinx, T ;
Maloney, RK .
OPHTHALMOLOGY, 2001, 108 (07) :1261-1265
[8]   Photorefractive keratectomy for hyperopia - Six months results in 45 eyes [J].
Daya, SM ;
Tappouni, FR ;
Habib, NE .
OPHTHALMOLOGY, 1997, 104 (11) :1952-1958
[9]   Laser in situ keratomileusis for hyperopia [J].
Ditzen, K ;
Huschka, H ;
Pieger, S .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (01) :42-47
[10]  
DURRIE DS, 1994, J REFRACT CORNEAL S, V10, pS277