Polymer microcantilever biochemical sensors with integrated polymer composites for electrical detection

被引:63
作者
Seena, V [1 ]
Rajorya, Anukool [1 ]
Pant, Prita [2 ]
Mukherji, Soumyo [3 ]
Rao, V. Ramgopal [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Ctr Excellence Nanoelect, Bombay 400076, Maharashtra, India
[2] Indian Inst Technol, Dept Met Engn & Mat Sci, Bombay 400076, Maharashtra, India
[3] Indian Inst Technol, Sch Biosci & Engn, Bombay 400076, Maharashtra, India
关键词
Biosensing; Microcantilever; Gauge factor; Young's modulus; Piezoresistor; Polymer; SU-8; Polymer carbon black composite; SU-8; IMMOBILIZATION;
D O I
10.1016/j.solidstatesciences.2009.06.009
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Micro fabricated sensors based on nanomechanical motion with piezoresistive electrical readout have become a promising biochemical sensing tool. The conventional microcantilever materials are mostly silicon-based. The sensitivity of the sensor depends on Young's modulus of the structural material, thickness of the cantilever as well as on the gauge factor of the piezoresistor. UV patternable polymers such as SU-8 have a very low Young's modulus compared to the silicon-based materials. Polymer cantilevers with a piezoresistive material having a large gauge factor and a lower Young's modulus are therefore highly suited for sensing applications. In this work, a spin coatable and photopatternable mixture of carbon black (CB) and SU-8, with proper dispersion characteristics, has been demonstrated as a piezoresistive thin film for polymer microcantilevers. Results on percolation experiments of SU-8/CB composite and fabrication of piezoresistive SU-8 microcantilevers using this composite are presented. With our controlled dispersion experiments, we could get a uniform piezoresistive thin film of thickness less than 1.2 mu m and resistivity of 2.7 Omega cm using 10 wt% of CB in SU-8. The overall thickness of the SU-8/composite/SU-8 is approximately 3 pm. We further present results on the electromechanical characterization and biofunctionalization of the cantilever structures for biochemical sensing applications. These cantilevers show a deflection sensitivity of 0.55 ppm/nm. Since the surface stress sensitivity is 4.1 x 10(-3) [N/m](-1), these cantilevers can well be used for detection of protein markers for pathological applications. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:1606 / 1611
页数:6
相关论文
共 11 条
  • [1] ARNTZ Y, 2003, LABEL FREE PROTEIN A
  • [2] CARRASCOSA LG, 2005, NANOMECHANICAL BIOSE
  • [3] Microfabricated photoplastic cantilever with integrated photoplastic/carbon based piezoresistive strain sensor
    Gammelgaard, L
    Rasmussen, PA
    Calleja, M
    Vettiger, P
    Boisen, A
    [J]. APPLIED PHYSICS LETTERS, 2006, 88 (11)
  • [4] GRUNLAN JC, MAT RES SOC S, V649
  • [5] A novel dry method for surface modification of SU-8 for immobilization of biomolecules in Bio-MEMS
    Joshi, Manoj
    Kale, Nitin
    Lal, Rakesh
    Rao, V. Ramgopal
    Mukherji, Soumyo
    [J]. BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) : 2429 - 2435
  • [6] Silanization and antibody immobilization on SU-8
    Joshi, Manoj
    Pinto, Richard
    Rao, V. Ramgopal
    Mukherji, Soumyo
    [J]. APPLIED SURFACE SCIENCE, 2007, 253 (06) : 3127 - 3132
  • [7] SU-8 cantilevers for bio/chemical sensing;: Fabrication, characterisation and development of novel read-out methods
    Nordstrom, Maria
    Keller, Stephan
    Lillemose, Michael
    Johansson, Alicia
    Dohn, Soren
    Haefliger, Daniel
    Blagoi, Gabriela
    Havsteen-Jakobsen, Mogens
    Boisen, Anja
    [J]. SENSORS, 2008, 8 (03) : 1595 - 1612
  • [8] THAYSEN J, P IEEE MEMS C 2002
  • [9] THAYSEN J, 2002, J PHYS D
  • [10] THAYSEN J, 2001, THESIS TU DENMARK