A CT-based analytical dose calculation method for HDR 192Ir brachytherapy

被引:20
|
作者
Poon, Emily [1 ]
Verhaegen, Frank [1 ,2 ]
机构
[1] McGill Univ, Med Phys Unit, Montreal, PQ H3G 1A4, Canada
[2] Univ Hosp Maastricht, GROW, Dept Radiat Oncol MAASTRO, NL-6229 ET Maastricht, Netherlands
关键词
Ir-192; brachytherapy; scatter; shielding; inhomogeneity corrections; COLLAPSED CONE SUPERPOSITION; ANALYTICAL DOSIMETRY MODEL; MONTE-CARLO; BREAST BRACHYTHERAPY; SCATTER CONTRIBUTION; HETEROGENEOUS MEDIA; YB-169; SOURCES; APPLICATOR; INHOMOGENEITIES; PARAMETERS;
D O I
10.1118/1.3184695
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This article presents an analytical dose calculation method for high-dose-rate Ir-192 brachytherapy, taking into account the effects of inhomogeneities and reduced photon backscatter near the skin. The adequacy of the Task Group 43 (TG-43) two-dimensional formalism for treatment planning is also assessed. Methods: The proposed method uses material composition and density data derived from computed tomography images. The primary and scatter dose distributions for each dwell position are calculated first as if the patient is an infinite water phantom. This is done using either TG-43 or a database of Monte Carlo (MC) dose distributions. The latter can be used to account for the effects of shielding in water. Subsequently, corrections for photon attenuation, scatter, and spectral variations along medium- or low-Z inhomogeneities are made according to the radiological paths determined by ray tracing. The scatter dose is then scaled by a correction factor that depends on the distances between the point of interest, the body contour, and the source position. Dose calculations are done for phantoms with tissue and lead inserts, as well as patient plans for head-and-neck, esophagus, and MammoSite balloon breast brachytherapy treatments. Gamma indices are evaluated using a dose-difference criterion of 3% and a distance-to-agreement criterion of 2 MM. PTRAN_CT MC calculations are used as the reference dose distributions. Results: For the phantom with tissue and lead inserts, the percentages of the voxels of interest passing the gamma criteria (P-gamma >= 1) are 100% for the analytical calculation and 91% for TG-43. For the breast patient plan, TG-43 overestimates the target volume receiving the prescribed dose by 4% and the dose to the hottest 0.1 cm(3) of the skin by 9%, whereas the analytical and MC results agree within 0.4%. P-gamma >= 1 are 100% and 48% for the analytical and TG-43 calculations, respectively. For the head-and-neck and esophagus patient plans, P-gamma >= 1 are >= 99% for both calculation methods. Conclusions: A correction-based dose calculation method has been validated for HDR Ir-192 brachytherapy. Its high calculation efficiency makes it feasible for use in treatment planning. Because tissue inhomogeneity effects are small and primary dose predominates in the near-source region, TG-43 is adequate for target dose estimation provided shielding and contrast solution are not used. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3184695]
引用
收藏
页码:3982 / 3994
页数:13
相关论文
共 50 条
  • [1] On the experimental validation of model-based dose calculation algorithms for 192Ir HDR brachytherapy treatment planning
    Pappas, Eleftherios P.
    Zoros, Emmanouil
    Moutsatsos, Argyris
    Peppa, Vasiliki
    Zourari, Kyveli
    Karaiskos, Pantelis
    Papagiannis, Panagiotis
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (10): : 4160 - 4182
  • [2] Development of a water calorimetry-based standard for absorbed dose to water in HDR 192Ir brachytherapy
    Sarfehnia, Arman
    Seuntjens, Jan
    MEDICAL PHYSICS, 2010, 37 (04) : 1914 - 1923
  • [3] The contribution from transit dose for 192Ir HDR brachytherapy treatments
    Fonseca, G. P.
    Landry, G.
    Reniers, B.
    Hoffmann, A.
    Rubo, R. A.
    Antunes, P. C. G.
    Yoriyaz, H.
    Verhaegen, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (07): : 1831 - 1844
  • [4] On source models for 192Ir HDR brachytherapy dosimetry using model based algorithms
    Pantelis, Evaggelos
    Zourari, Kyveli
    Zoros, Emmanouil
    Lahanas, Vasileios
    Karaiskos, Pantelis
    Papagiannis, Panagiotis
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (11): : 4235 - 4246
  • [5] Gafchromic film dosimetry of a new HDR 192Ir brachytherapy source
    Ayoobian, Navid
    Asl, Akbar Sarabi
    Poorbaygi, Hosein
    Javanshir, Mohammad Reza
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 194 - 205
  • [6] Determination of transit dose profile for a 192Ir HDR source
    Fonseca, G. P.
    Rubo, R. A.
    Minamisawa, R. A.
    dos Santos, G. R.
    Antunes, P. C. G.
    Yoriyaz, H.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [7] Dose optimization of breast balloon brachytherapy using a stepping 192Ir HDR source
    Choi, Chang Hyun
    Ye, Sung-Joon
    Parsai, E. Ishmael
    Shen, Sui
    Meredith, Ruby
    Brezovich, Ivan A.
    Ove, Roger
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (01): : 90 - 102
  • [8] Dosimetric characterization of round HDR 192Ir AccuBoost applicators for breast brachytherapy
    Rivard, Mark J.
    Melhus, Christopher S.
    Wazer, David E.
    Bricault, Raymond J., Jr.
    MEDICAL PHYSICS, 2009, 36 (11) : 5027 - 5032
  • [9] Development of a scatter correction technique and its application to HDR 192Ir multicatheter breast brachytherapy
    Poon, Emily
    Verhaegen, Frank
    MEDICAL PHYSICS, 2009, 36 (08) : 3703 - 3713
  • [10] Dosimetry revisited for the HDR 192Ir brachytherapy source model mHDR-v2
    Granero, Domingo
    Vijande, Javier
    Ballester, Facundo
    Rivard, Mark J.
    MEDICAL PHYSICS, 2011, 38 (01) : 487 - 494