Preliminary experience with biodegradable implants for fracture fixation

被引:11
作者
Dhillon, Mandeep S. [1 ]
Prabhakar, Sharad [1 ]
Prasanna, Chandiralingam [1 ]
机构
[1] Postgrad Inst Med Educ & Res, Dept Orthoped Surg, Chandigarh 160012, India
关键词
Biodegradable implants; fractures; surgeon confidence;
D O I
10.4103/0019-5413.41856
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Biodegradable implants were designed to overcome the disadvantages of metal-based internal fixation devices. Although they have been in use for four decades internationally, many surgeons in India continue to be skeptical about the mechanical strength of biodegradable implants, hence this study. Materials and Methods: A prospective study was done to assess the feasibility and surgeon confidence level with biodegradable implants over a 12-month period in an Indian hospital. Fifteen fractures (intra-articular, metaphyseal or small bone fractures) were fixed with biodegradable implants. The surgeries were randomly scheduled so that different surgeons with different levels of experience could use the implants for fixation. Results: Three fractures (one humeral condyle, two capitulum), were supplemented by additional K-wires fixation. Trans-articular fixator was applied in two distal radius and two pilon fractures where bio-pins alone were used. All fractures united, but in two cases the fracture displaced partially during the healing phase; one fibula due to early walking, and one radius was deemed unstable even after bio-pin and external fixator. Conclusions: Biodegradable -implants are excellent for carefully selected cases of intra-articular fractures and some small bone fractures. However, limitations for use in long bone fractures persist and no great advantage is gained if a "hybrid" composite is employed. The mechanical properties of biopins and screws in isolation are perceived to be inferior to those of conventional metal implants, leading to low confidence levels regarding the stability of reduced fractures; these implants should be used predominantly in fracture patterns in which internal fixation is subjected to minimal stress.
引用
收藏
页码:319 / 322
页数:4
相关论文
共 13 条
[1]   METALLIC WEAR IN FAILED TITANIUM-ALLOY TOTAL HIP REPLACEMENTS - A HISTOLOGICAL AND QUANTITATIVE-ANALYSIS [J].
AGINS, HJ ;
ALCOCK, NW ;
BANSAL, M ;
SALVATI, EA ;
WILSON, PD ;
PELLICCI, PM ;
BULLOUGH, PG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :347-356
[2]   Removal of asymptomatic bone plates used for orthognathic surgery and facial fractures [J].
Alpert, B ;
Seligson, D .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (05) :618-621
[3]   Surgical options for the treatment of severe tibial pilon fractures: A study of three techniques [J].
Blauth, M ;
Bastian, L ;
Krettek, C ;
Knop, C ;
Evans, S .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) :153-160
[4]  
Böstman OM, 2000, CLIN ORTHOP RELAT R, P216
[5]  
Dhillon M., 2006, INDIAN J ORTHOP, V40, P205
[6]  
DHILLON MS, 2006, J FOOT ANKLE SURG, V21, P1
[7]   Tissue response to titanium plates: A transmitted electron microscopic study [J].
Kim, YK ;
Yeo, HH ;
Lim, SC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1997, 55 (04) :322-326
[8]   SENSITIVITY TO TITANIUM - A CAUSE OF IMPLANT FAILURE [J].
LALOR, PA ;
REVELL, PA ;
GRAY, AB ;
WRIGHT, S ;
RAILTON, GT ;
FREEMAN, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (01) :25-28
[9]   Principles of development and use of absorbable internal fixation [J].
Pietrzak, WS .
TISSUE ENGINEERING, 2000, 6 (04) :425-433
[10]  
ROKKANEN P, 1990, ACTA ORTHOP SCAND, V235, P51