Response time of the Opti-Q continuous cardiac output pulmonary artery catheter in the urgent mode to a step change in cardiac output

被引:4
作者
Goldstein, LJ [1 ]
机构
[1] Univ Calif, Dept Surg, Oakland, CA 94602 USA
关键词
continuous cardiac output; thermodilution; pulmonary artery catheter; response time;
D O I
10.1023/A:1009934112134
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objectives. This study was conducted to determine the response time of the Opti-Q continuous cardiac output (CCO) device to a step change in cardiac. Design. Prospective study. Setting. University hospital animal lab. Model. Female sheep. Interventions. In ten animals, cardiac output was altered suddenly by opening and closing a peripheral arteriovenous shunt to test the response time of the CCO system. Measurements and main results. Cardiac output was measured continuously by thermodilution and ultrasonic techniques while an arteriovenous shunt was opened and closed. A total of 53 dynamic observations were made (5-6 per animal). The mean response time of the continuous cardiac output device was 86 seconds and was unaffected by the magnitude or direction of the change in cardiac output. It was also unaffected by the animal's weight. CCO values were not statistically different from standard thermodilution measurement (p = 0.895). Shunt flow ranged from 430 to 1730 ml/min and averaged 812 ml/min. The mean CCO with the shunt closed was 4.62 L/min. There was 1.5 to 2 minutes under or overshoot in cardiac output in 11% of the measurements. Conclusions. Continuous cardiac output measurement was as accurate as those made by standard bolus thermodilution. The average response time to acute changes in cardiac output was approximately 1.5 minutes or ten times faster than previously reported systems. Response time is independent of animal mass, shunt volume and the direction of cardiac output perturbations.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 19 条
  • [1] BOLDT J, 1994, CRIT CARE MED, V22, P1913
  • [2] Evaluation of a continuous cardiac output and mixed venous oxygen saturation catheter in critically ill surgical patients
    Burchell, SA
    Yu, MH
    Takiguchi, SA
    Ohta, RM
    Myers, SA
    [J]. CRITICAL CARE MEDICINE, 1997, 25 (03) : 388 - 391
  • [3] Ditmyer C E, 1995, Am J Crit Care, V4, P460
  • [4] EVALUATION OF A NEW CONTINUOUS THERMODILUTION CARDIAC-OUTPUT MONITOR IN CRITICALLY ILL PATIENTS - A PROSPECTIVE CRITERION STANDARD STUDY
    HALLER, M
    ZOLLNER, C
    BRIEGEL, J
    FORST, H
    [J]. CRITICAL CARE MEDICINE, 1995, 23 (05) : 860 - 866
  • [5] HOGUE CW, 1993, ANESTHESIOLOGY, V79, pA467
  • [6] Analysis of the accuracy of continuous thermodilution cardiac output measurement - Comparison with intermittent thermodilution and Fick cardiac output measurement
    Jacquet, L
    Hanique, G
    Glorieux, D
    Matte, P
    Goenen, M
    [J]. INTENSIVE CARE MEDICINE, 1996, 22 (10) : 1125 - 1129
  • [7] Lazor MA, 1996, ANESTH ANALG, V82, pSCA71
  • [8] Evaluation of the accuracy and response time of STAT-mode continuous cardiac output
    Lazor, MA
    Pierce, ET
    Stanley, GD
    Cass, JL
    Halpern, EF
    Bode, RH
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1997, 11 (04) : 432 - 436
  • [9] LeTulzo Y, 1996, J CLIN MONITOR, V12, P379
  • [10] LICHTENTHAL PR, 1993, CRIT CARE MED, V21, pS214