Mid-Term Results after Volar Plating of Distal Radius Fractures with a Newly Designed Locking Plate

被引:1
作者
Wick, M. [1 ]
Wiesner, M. [1 ]
机构
[1] Krankenhaus Eggenfelden, D-84307 Eggenfelden, Germany
来源
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE | 2010年 / 148卷 / 01期
关键词
distal radius fracture; fixed angle; volar plate; COMPRESSION PLATES; ELDERLY-PATIENTS; FIXATION; COMPLICATIONS; MANAGEMENT; ADVANTAGES; RUPTURE; DORSAL; TENDON;
D O I
10.1055/s-0029-1186203
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The purpose of this retrospective study was to investigate the clinical and radiographic results after operative treatment of dislocated distal radius fractures with a new self-locking volar plate system. Patients and Methods: 67 patients (average age 61.4 years) with a dislocated distal radius fracture were treated with the ITS (R) plate system. Clinical and radiographic evaluation was done with a mean follow-up of 9.3 months. Results: The mean DASH score reached 14 points, the modified Gartland/Werley score was 6.9. There was one loss of reduction on radiographic evaluation, which yielded to a dorsal osteosynthesis. Average postoperative radial inclination was 20.5 (16-29) and the volar tilt 9.3 (315). One plate had to be removed after three months because of dislocation of a malpositioned screw. There were no cases of infection or tendon ruptures. No patient required autograft bone. Conclusion: This new locking plate system offers an excellent option in the treatment of dislocated distal radius fractures, especially in osteoporotic bone with a dorsal comminution.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 32 条
[1]   Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures [J].
Al-Rashid, M. ;
Theivendran, K. ;
Craigen, M. A. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12) :1610-1612
[2]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[3]   Two potential causes of EPL rupture after distal radius volar plate fixation [J].
Benson, Eric C. ;
DeCarvalho, Alex ;
Mikola, Elizabeth A. ;
Veitch, John M. ;
Moneim, Moheb S. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) :218-222
[4]   Management of distal radial fractures [J].
Chen, Neal C. ;
Jupiter, Jesse B. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09) :2051-2062
[5]   Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6
[6]  
Einsiedel T, 2006, Z GERONTOL GERIATR, V39, P451, DOI 10.1007/s00391-006-0378-2
[7]  
Elsaidi Gamal A, 2007, Am J Orthop (Belle Mead NJ), V36, P269
[8]   Long-term outcome of nonsurgically treated distal radius fractures [J].
Foldhazy, Zoltan ;
Tornkvist, Hans ;
Elmstedt, Erik ;
Andersson, Gunilla ;
Hagsten, Birgit ;
Ahrengart, Leif .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (09) :1374-1384
[9]  
Germann G, 1999, Handchir Mikrochir Plast Chir, V31, P149, DOI 10.1055/s-1999-13902
[10]  
Handoll H.H.G., 2003, COCHRANE DB SYST REV, DOI [DOI 10.1002/14651858.CD003209, 10.1002/14651858.Cd003209]