The ACE1 Electrical Impedance Tomography System for Thoracic Imaging

被引:1
作者
Mellenthin, Michelle M. [1 ,2 ]
Mueller, Jennifer L. [1 ,3 ,4 ]
Leon Bueno de Camargo, Erick Dario [5 ]
de Moura, Fernando Silva [5 ]
Rattis Santos, Talles Batista [6 ]
Lima, Raul Gonzalez [6 ]
Hamilton, Sarah J. [7 ]
Muller, Peter A. [3 ,8 ]
Alsaker, Melody [3 ,9 ]
机构
[1] Colorado State Univ, Sch Biomed Engn, Ft Collins, CO 80523 USA
[2] Univ Colorado, Dept Bioengn, Aurora, CO 80045 USA
[3] Colorado State Univ, Dept Math, Ft Collins, CO 80523 USA
[4] Colorado State Univ, Dept Elect & Comp Engn, Ft Collins, CO 80523 USA
[5] Fed Univ ABC, Ctr Engn Modeling & Appl Social Sci, BR-09606070 Sao Bernardo Do Campo, Brazil
[6] Univ Sao Paulo, Mech Engn Dept, BR-09210580 Sao Paulo, Brazil
[7] Marquette Univ, Dept Math Stat & Comp Sci, Milwaukee, WI 53233 USA
[8] Rowan Univ, Math Dept, Glassboro, NJ 08028 USA
[9] Gonzaga Univ, Dept Math, Spokane, WA 99258 USA
关键词
Biomedical imaging; electrical impedance tomography (EIT); thoracic imaging; MULTIFREQUENCY EIT SYSTEM; REGIONAL LUNG VENTILATION; D-BAR METHOD; CONDUCTIVITY; IMPLEMENTATION; DESIGN; DISTINGUISHABILITY; RECONSTRUCTIONS; PERMITTIVITY; PERFORMANCE;
D O I
10.1109/TIM.2018.2874127
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design and performance of the active complex electrode (ACE1) electrical impedance tomography system for single-ended phasic voltage measurements are presented. The design of the hardware and calibration procedures allows for reconstruction of conductivity and permittivity images. Phase measurement is achieved with the ACE1 active electrode circuit which measures the amplitude and phase of the voltage and the applied current at the location at which current is injected into the body. An evaluation of the system performance under typical operating conditions includes details of demodulation and calibration and an in-depth look at insightful metrics, such as signal-to-noise ratio variations during a single current pattern. Static and dynamic images of conductivity and permittivity are presented from ACE1 data collected on tank phantoms and human subjects to illustrate the system's utility.
引用
收藏
页码:3137 / 3150
页数:14
相关论文
共 50 条
[21]   Microelectrode array electrical impedance tomography for fast functional imaging in the thalamus [J].
Zhu, Danyi ;
McEwan, Alistair ;
Eiber, Calvin .
NEUROIMAGE, 2019, 198 :44-52
[22]   Electrical impedance tomography with deep Calderon method [J].
Cen, Siyu ;
Jin, Bangti ;
Shin, Kwancheol ;
Zhou, Zhi .
JOURNAL OF COMPUTATIONAL PHYSICS, 2023, 493
[23]   An alternative excitation method for electrical impedance tomography [J].
Cui, Ziqiang ;
Yang, Pengyu ;
Li, Xuan ;
Wang, Huaxiang .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (04)
[24]   A Hybrid Segmentation and D-Bar Method for Electrical Impedance Tomography [J].
Hamilton, S. J. ;
Reyes, J. M. ;
Siltanen, S. ;
Zhang, X. .
SIAM JOURNAL ON IMAGING SCIENCES, 2016, 9 (02) :770-793
[25]   Multiphase Conductivity Imaging With Electrical Impedance Tomography and B-Spline Level Set Method [J].
Liu, Dong ;
Gu, Danping ;
Smyl, Danny ;
Deng, Jiansong ;
Du, Jiangfeng .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (12) :9634-9644
[26]   Mathematical framework for a new microscopic electrical impedance tomography system [J].
Lee, Eunjung ;
Seo, Jin Keun ;
Woo, Eung Je ;
Zhang, Tingting .
INVERSE PROBLEMS, 2011, 27 (05)
[27]   Development of a Portable Electrical Impedance Tomography System for Biomedical Applications [J].
Xu, Zifei ;
Yao, Jiafeng ;
Wang, Zheng ;
Liu, Yanli ;
Wang, Hao ;
Chen, Bai ;
Wu, Hongtao .
IEEE SENSORS JOURNAL, 2018, 18 (19) :8117-8124
[28]   A multi-frequency electrical impedance tomography system for real-time 2D and 3D imaging [J].
Yang, Yunjie ;
Jia, Jiabin .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (08)
[29]   Fast absolute 3D CGO-based electrical impedance tomography on experimental tank data [J].
Hamilton, S. J. ;
Muller, P. A. ;
Isaacson, D. ;
Kolehmainen, V ;
Newell, J. ;
Rajabi Shishvan, O. ;
Saulnier, G. ;
Toivanen, J. .
PHYSIOLOGICAL MEASUREMENT, 2022, 43 (12)
[30]   Focused Current Density Imaging Using Internal Electrode in Magnetic Resonance Electrical Impedance Tomography (MREIT) [J].
Jeong, Woo Chul ;
Sajib, Saurav Z. K. ;
Kim, Hyung Joong ;
Kwon, Oh In .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (07) :1938-1946