High performance control strategy for single-phase three-level neutral-point-clamped traction four-quadrant converters

被引:9
作者
Kejian, Song [1 ]
Konstantinou, Georgios [2 ]
Li Jing [1 ]
Wu Mingli [1 ]
Agelidis, Vassilios Georgios [3 ]
机构
[1] Beijing Jiaotong Univ, Sch Elect Engn, Beijing 100044, Peoples R China
[2] Univ New South Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
[3] Tech Univ Denmark, Dept Elect Engn, DK-2800 Lyngby, Denmark
关键词
power convertors; traction power supplies; frequency control; electric current control; voltage control; notch filters; electric vehicles; railway electrification; high performance control strategy; single-phase three-level neutral-point-clamped traction four-quadrant converters; Chinese railways; 4QC control; current harmonics; reference tracking; low-order voltage; electric multiple unit traction system; multiple frequency tuned quasiproportional resonant controller; ac-side current loop; multiple frequency tuned notch filter; dc-link voltage loop; supply voltage distortion; current tracking performance; line current harmonics; CONTROL SCHEME; PWM; MODULATION; DESIGN; SYSTEM; ERROR;
D O I
10.1049/iet-pel.2016.0153
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Operational data from Chinese railways indicate a number of challenges for traction four-quadrant converter (4QC) control including low-order voltage and current harmonics and reference tracking. A control strategy for a single-phase three-level neutral-point-clamped 4QC employed in the electric multiple unit traction system is proposed in this study. The strategy is based on a multiple frequency tuned quasi-proportional resonant controller in the ac-side current loop and a multiple frequency tuned notch filter in the dc-link voltage loop. Under the typical supply voltage distortion present in the network, the proposed control strategy improves the current tracking performance and reduces the line current harmonics, when compared with conventional control strategies. Experimental results, both under purely sinusoidal and distorted supply voltages, validate the effectiveness of the proposed control strategy.
引用
收藏
页码:884 / 893
页数:10
相关论文
共 30 条
[1]   A Single-Objective Predictive Control Method for a Multivariable Single-Phase Three-Level NPC Converter-Based Active Power Filter [J].
Acuna, Pablo ;
Moran, Luis ;
Rivera, Marco ;
Aguilera, Ricardo ;
Burgos, Rolando ;
Agelidis, Vassilios G. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (07) :4598-4607
[2]   Resonant harmonic elimination pulse width modulation-based high-frequency resonance suppression of high-speed railways [J].
Cui, Hengbin ;
Song, Wensheng ;
Fang, Hui ;
Ge, Xinglai ;
Feng, Xiaoyun .
IET Power Electronics, 2015, 8 (05) :735-742
[3]   Optimal Low Switching Frequency Pulsewidth Modulation of Nine-Level Cascade Inverter [J].
Edpuganti, Amarendra ;
Rathore, Akshay K. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (01) :482-495
[4]  
Fukuda S, 2001, IEEE T IND APPL, V37, P888, DOI 10.1109/28.924772
[5]   Power Quality Issues in Railway Electrification: A Comprehensive Perspective [J].
Gazafrudi, Sayed Mohammad Mousavi ;
Langerudy, Adel Tabakhpour ;
Fuchs, Ewald F. ;
Al-Haddad, Kamal .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (05) :3081-3090
[6]  
Hart NH, 2012, I C MECH MACH VIS PR, P1
[7]   High-Performance Indirect Current Control Scheme for Railway Traction Four-Quadrant Converters [J].
He, Liqun ;
Xiong, Jian ;
Ouyang, Hui ;
Zhang, Pengju ;
Zhang, Kai .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (12) :6645-6654
[8]  
Huang XJ, 2009, IEEE INT POWER ELEC, P1960
[9]  
Kang SW, 2013, IEEE IND ELEC, P7769, DOI 10.1109/IECON.2013.6700429
[10]   Zero-steady-state-error input-current controller for regenerative multilevel converters based on single-phase cells [J].
Lezana, Pablo ;
Silva, Cesar A. ;
Rodriguez, Jose ;
Perez, Marcelo A. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (02) :733-740