Electrochemical Detection of Dopamine and Serotonin in the Presence of Interferences in a Rotating Droplet System

被引:39
作者
Kundys-Siedlecka, Magdalena [1 ]
Baczynska, Ewa [1 ,2 ]
Jonsson-Niedziolka, Martin [1 ]
机构
[1] Polish Acad Sci, Inst Phys Chem, Kasprzaka 44-52, PL-01224 Warsaw, Poland
[2] Polish Acad Sci, Nencki Inst Expt Biol, Pasteura 3, PL-02093 Warsaw, Poland
关键词
GOLD NANOPARTICLES; ASCORBIC-ACID; HYDROGEN-PEROXIDE; URIC-ACID; NEUROTRANSMITTERS; ELECTRODES; RECEPTORS; COMPOSITE; RELEASE; SENSOR;
D O I
10.1021/acs.analchem.9b02967
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this Article, a rotating droplet system is used for simultaneous detection of dopamine and serotonin. Carbon nanoparticles functionalized with sulfonic groups on the electrode surface enables potential discrimination between the neurotransmitters and the most common interferences, whereas the efficient and low-volume hydrodynamic system helps to lower the detection limit toward physiologically relevant concentrations. Here, we present results with a 10 nM limit of detection for serotonin and a 100 nM to 2 mu M linear response range from the system in a sample containing an equimolar concentrations of dopamine and serotonin and 0.5 mM concentration of both uric and ascorbic acids. Demonstrating the practical applicability of this method, we measure the concentration of serotonin in 70 mu L of mice blood serum samples without additional pretreatment.
引用
收藏
页码:10908 / 10913
页数:6
相关论文
共 34 条
[11]   Clinical chemistry of serotonin and metabolites [J].
Kema, IP ;
de Vries, EGE ;
Muskiet, FAJ .
JOURNAL OF CHROMATOGRAPHY B, 2000, 747 (1-2) :33-48
[12]   Preparation of electro-reduced graphene oxide supported walnut shape nickel nanostructures, and their application to selective detection of dopamine [J].
Kumar, M. Kaleesh ;
Prataap, R. K. Vishnu ;
Mohan, S. ;
Jha, Shailendra K. .
MICROCHIMICA ACTA, 2016, 183 (05) :1759-1768
[13]   Generation-Collection Electrochemistry Inside a Rotating Droplet [J].
Kundys, Magdalena ;
Nejbauer, Michal ;
Jonsson-Niedziolka, Martin ;
Adamiak, Wojciech .
ANALYTICAL CHEMISTRY, 2017, 89 (15) :8057-8063
[14]   Rotating droplet as a new alternative for small volume electrochemical measurements [J].
Kundys, Magdalena ;
Adamiak, Wojciech ;
Jonsson-Niedziolka, Martin .
ELECTROCHEMISTRY COMMUNICATIONS, 2016, 72 :46-49
[15]   Electrochemical determination of selected neurotransmitters at electrodes modified with oppositely charged carbon nanoparticles [J].
Kundys, Magdalena ;
Szot, Katarzyna ;
Rozniecka, Ewa ;
Joensson-Niedziolka, Martin ;
Lawrence, Ruth ;
Bull, Steven D. ;
Marken, Frank ;
Opallo, Marcin .
ANALYTICAL METHODS, 2014, 6 (18) :7532-7539
[16]   Measurement of Plasma, Serum, and Platelet Serotonin in Individuals With High Bone Mass and Mutations in LRP5 [J].
Lee, Grace S. ;
Simpson, Christine ;
Sun, Ben-Hua ;
Yao, Chen ;
Foer, Dinah ;
Sullivan, Becky ;
Matthes, Susann ;
Alenina, Natalia ;
Belsky, Joseph ;
Bader, Michael ;
Insogna, Karl L. .
JOURNAL OF BONE AND MINERAL RESEARCH, 2014, 29 (04) :976-981
[17]   An Ultrasensitive Nanowire-Transistor Biosensor for Detecting Dopamine Release from Living PC12 Cells under Hypoxic Stimulation [J].
Li, Bor-Ran ;
Hsieh, Ying-Jhu ;
Chen, Yan-Xi ;
Chung, Ya-Ting ;
Pan, Chien-Yuan ;
Chen, Yit-Tsong .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2013, 135 (43) :16034-16037
[18]   Neurotransmitter receptors on microglia [J].
Liu, Huan ;
Leak, Rehana K. ;
Hu, Xiaoming .
STROKE AND VASCULAR NEUROLOGY, 2016, 1 (02) :52-58
[19]   One-step hydrothermal green synthesis of silver nanoparticle-carbon nanotube reduced-graphene oxide composite and its application as hydrogen peroxide sensor [J].
Lorestani, Farnaz ;
Shahnavaz, Zohreh ;
Mn, Pooria ;
Alias, Yatimah ;
Manan, Ninie S. A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 :389-398
[20]  
Maughan N, 2015, ANAL BIOANAL ELECTRO, V7, P1