Steady-state blood volume measurements in experimental tumors with different angiogenic burdens - A study in mice

被引:74
作者
Bremer, C
Mustafa, M
Bogdanov, A
Ntziachristos, V
Petrovsky, A
Weissleder, R
机构
[1] Massachusetts Gen Hosp, Ctr Mol Imaging Res, Charlestown, MA 02129 USA
[2] Harvard Univ, Sch Med, Charlestown, MA 02129 USA
关键词
angiogenesis; contrast media; experimental studies; experimental study; neoplasms; radionuclide studies;
D O I
10.1148/radiol.2261012140
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To experimentally validate the effectiveness of magnetic resonance (MR) imaging enhanced with long-circulating iron oxide for measurement of vascular volume fractions (VVFs) as indicators of angiogenesis in different experimental tumor models. MATERIALS AND METHODS: Tumors with differing degrees of angiogenesis-9L rodent gliosarcoma, DU4475 human mammary adenocarcinoma, HT1080 human fibrosarcoma, and EOMA hemangioendothelioma-were implanted in nude mice. Tumoral VVFs were measured at submillimeter voxel resolutions by using 1.5-TMR imaging. A technetium-labeled intravascular radiotracer was injected into a subset of the animals to validate the MR imaging measurements. Microvessel density and vascular endothelial growth factor (VEGF) also were measured. Statistical analysis was performed with analysis of variance. RESULTS: High-resolution multisection MR maps of tumor blood volume were obtained in all tumor models. Mean tumoral VVF differed significantly among the different tumors: 2.1% +/- 0.3 (standard error of mean) for 9L gliosarcoma, 3.1% +/- 0.4 for DU4475 mammary adenocarcinoma, 5.5% +/- 0.8 for HT1080 fibrosarcoma, and 6.6% +/- 0.9 for EOMA hemangioendothelioma (P<.01). There was a strong correlation between the MR imaging and radiotracer measurements. There was considerable intra- and intertumoral heterogeneity among the VVFs. MR imaging measurements were in accordance with conventional measurements of angiogenesis, such as microvessel density count and VEGF. CONCLUSION: Measurements of tumoral VVF at high-resolution MR imaging with long-circulating iron oxide are feasible and correlate with angiogenic burden in experimental tumor models. (C) RSNA, 2002.
引用
收藏
页码:214 / 220
页数:7
相关论文
共 30 条
[1]   Approaches and agents for imaging the vascular system [J].
Bogdanov, AA ;
Lewin, M ;
Weissleder, R .
ADVANCED DRUG DELIVERY REVIEWS, 1999, 37 (1-3) :279-293
[2]   MR CONTRAST DUE TO INTRAVASCULAR MAGNETIC-SUSCEPTIBILITY PERTURBATIONS [J].
BOXERMAN, JL ;
HAMBERG, LM ;
ROSEN, BR ;
WEISSKOFF, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) :555-566
[3]   Assessing tumor angiogenesis using macromolecular MR imaging contrast media [J].
Brasch, R ;
Pham, C ;
Shames, D ;
Roberts, T ;
vanDijke, K ;
vanBruggen, N ;
Mann, J ;
Ostrowitzki, S ;
Melnyk, O .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :68-74
[4]  
Browder T, 2000, CANCER RES, V60, P1878
[5]  
CALLAHAN R, 1995, J NUCL MED, pP157
[6]   Preclinical evaluation and phase I clinical trial of a 99mTc-labeled synthetic polymer used in blood pool imaging [J].
Callahan, RJ ;
Bogdanov, A ;
Fischman, AJ ;
Brady, TJ ;
Weissleder, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) :137-143
[7]   Angiogenesis in cancer and other diseases [J].
Carmeliet, P ;
Jain, RK .
NATURE, 2000, 407 (6801) :249-257
[8]   NMR imaging of changes in vascular morphology due to tumor angiogenesis [J].
Dennie, J ;
Mandeville, JB ;
Boxerman, JL ;
Packard, SD ;
Rosen, BR ;
Weisskoff, RM .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (06) :793-799
[9]  
Enochs WS, 1999, JMRI-J MAGN RESON IM, V9, P228, DOI 10.1002/(SICI)1522-2586(199902)9:2<228::AID-JMRI12>3.3.CO
[10]  
2-B