Effects of synchronous machine saturation, circuit parameters, and control systems on transient stability

被引:0
|
作者
Kar, NC [1 ]
Murata, T [1 ]
Tamura, J [1 ]
机构
[1] Kitami Inst Technol, Dept Elect & Elect Engn, Kitami, Hokkaido 0908507, Japan
来源
ELECTRIC MACHINES AND POWER SYSTEMS | 2000年 / 28卷 / 07期
关键词
synchronous machine; d- and q-axis equivalent circuits; saturation; critical clearing time; transient stability;
D O I
10.1080/073135600268126
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effects of synchronous machine iron saturation, circuit parameters, and control systems on the power system transient stability phenomena are presented in this paper. Effect of saturation is considered to be very important on the power system steady-state and transient performances when it is required to calculate the power system stability characteristics accurately. For solid round rotor body synchronous machines, saturation effects are significant in both d- and q-axis, and because of this nonlinearity, the d- and q-axis magnetizing reactances are depressed to a considerable degree from their unsaturated values tinder both steady-state and transient operations. The system stability performance is also greatly influenced by the machine control system and damper circuit parameter variations.
引用
收藏
页码:663 / 675
页数:13
相关论文
共 50 条
  • [41] OPTIMIZED TRANSIENT STABILITY FROM EXCITATION CONTROL OF SYNCHRONOUS GENERATORS
    DINELEY, JL
    MORRIS, AJ
    PREECE, C
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1968, PA87 (08): : 1696 - &
  • [42] Transient stability analysis and control strategy of virtual synchronous generator
    Wang J.-L.
    Zhang X.
    Zhu Q.-H.
    Han F.
    Fu X.-X.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2022, 26 (12): : 28 - 37
  • [43] Transient Stability Enhancement Strategy for Islanded Microgrids Based on Energy Storage-Virtual Synchronous Machine Control
    Ma, Chenghao
    Sun, Jiahang
    Huang, Jingguang
    Wang, Kaijie
    ENERGIES, 2023, 16 (17)
  • [44] Parameter-measurement and control of the synchronous reluctance machine including cross saturation
    Kilthau, A
    Pacas, JM
    CONFERENCE RECORD OF THE 2001 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2001, : 2302 - 2309
  • [45] Optimal reference voltage saturation for nonlinear current control of synchronous machine drives
    Monzen, Niklas
    Hackl, Christoph M.
    2024 IEEE 21ST INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, PEMC 2024, 2024,
  • [46] Improving Power Systems Transient Stability by Coordinated Control of Energy Storage Systems and Synchronous Generators in Presence of Measurement Noise
    Rostami, Mohammadali
    Kiaei, Iman
    Lotfifard, Saeed
    IEEE SYSTEMS JOURNAL, 2020, 14 (01): : 1088 - 1097
  • [47] A hybrid approach in the study of UPFC effects on transient stability of multi machine power systems
    Kazemi, A
    Naghshbandy, AH
    ELECTRICAL ENGINEERING, 2006, 88 (02) : 125 - 131
  • [48] Finite Element Computation of Transient Parameters of a Salient-Pole Synchronous Machine
    Xiao, Yang
    Zhou, Libing
    Wang, Jin
    Yang, Rui
    ENERGIES, 2017, 10 (07):
  • [49] A hybrid approach in the study of UPFC effects on transient stability of multi machine power systems
    A. Kazemi
    A. Hessamy Naghshbandy
    Electrical Engineering, 2006, 88 : 125 - 131
  • [50] DERIVATION OF SYNCHRONOUS MACHINE STABILITY PARAMETERS FROM POLE SLIPPING CONDITIONS
    DEMELLO, FP
    HANNETT, LN
    SMITH, D
    WETZEL, L
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (09): : 3394 - 3402