Breath-by-breath fluctuations of pulmonary gas exchange and ventilation in COPD patients

被引:18
作者
Puente-Maestu, L
Abad, MJB
Godoy, R
Pérez-Parra, JM
Cubillo, JM
Whipp, BJ
机构
[1] Hosp Gen Univ Gregorio Maranon, Serv Neumol, Madrid 28007, Spain
[2] Univ London, Dept Physiol, St Georges Hosp Med Sch, London, England
关键词
oxygen uptake; carbon dioxide output; kinetic response to exercise; obstructive lung disease; error source;
D O I
10.1007/s00421-002-0649-6
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of the study was to characterise statistically the inherent fluctuations in breath-by-breath measurements of pulmonary gas exchange (oxygen uptake and carbon dioxide output, (V) over dot O-2 and (V) over dot CO2, respectively) and pulmonary ventilation WE) in patients with chronic obstructive pulmonary disease (COPD) and to compare them with those of healthy control subjects. Thirty subjects with COPD [mean (SD): 67 (6) years old; forced expiratory volume in 1 min, FEV1 1.25(0.18) 1; 42 (6)% predicted FEV1] and 12 healthy subjects [31 (3) years old; FEV1 3.62 (0.54) 1; 99 (8)% predicted FEV1] performed exercise tests on a cycle ergometer at a constant work rate of moderate intensity. Steady-state exercise values for (V) over dot O-2, (V) over dot CO2 and (V) over dot (E) were 905 (96) ml.min(-1), 847(90) ml.min(-1) and 23 (3) l.min(-1) respectively for the COPD patients and 1239(89) ml.min(-1), l.min(-1), 1191(84) ml.min(-1) and 37(3) l.min(-1), respectively, for the healthy controls. The breath-by-breath fluctuations were well characterised by a Gaussian density-probability function with breath-to-breath autocorrelations that were not significantly different from 0, up to four subsequent breaths. Its magnitude varied among variables, but was independent of the signal amplitude for the same subject and variable. With ratios of amplitude of fluctuation: signal of around 10%, typical of the patients studied, the resolution of time e constants and amplitude were congruent to9 s and congruent to 100 ml.min(-1) respectively for (V) over dot O-2 or (V) over dot CO2 with one repetition.
引用
收藏
页码:535 / 541
页数:7
相关论文
共 22 条
[2]   A NEW METHOD FOR DETECTING ANAEROBIC THRESHOLD BY GAS-EXCHANGE [J].
BEAVER, WL ;
WASSERMAN, K ;
WHIPP, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (06) :2020-2027
[3]   BREATH-BY-BREATH MEASUREMENT OF TRUE ALVEOLAR GAS-EXCHANGE [J].
BEAVER, WL ;
LAMARRA, N ;
WASSERMAN, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (06) :1662-1675
[4]  
BECK KC, 1991, EXERCISE PULMONARY P, P67
[5]   Physiologic benefits of exercise training in rehabilitation of patients with severe chronic obstructive pulmonary disease [J].
Casaburi, R ;
Porszasz, J ;
Burns, MR ;
Carithers, ER ;
Chang, RSY ;
Cooper, CB .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (05) :1541-1551
[6]  
CELLI BR, 1995, AM J RESP CRIT CARE, V152, pS77
[7]  
Conover W. J., 1980, PRACTICAL NONPARAMET
[8]  
DODD DS, 1984, AM REV RESPIR DIS, V129, P33
[9]   OXYGEN-UPTAKE TRANSIENT KINETICS DURING CONSTANT-LOAD EXERCISE IN CHILDREN AFTER OPERATIONS OF VENTRICULAR SEPTAL-DEFECT, TETRALOGY OF FALLOT, TRANSPOSITION OF THE GREAT-ARTERIES, OR TRICUSPID-VALVE ATRESIA [J].
GILDEIN, P ;
MOCELLIN, R ;
KAUFMEHL, K .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (02) :166-169
[10]   PREDICTED VALUES FOR CLINICAL EXERCISE TESTING [J].
HANSEN, JE ;
SUE, DY ;
WASSERMAN, K .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1984, 129 (02) :S49-S55