A MEMS-Based Flow Rate and Flow Direction Sensing Platform with Integrated Temperature Compensation Scheme

被引:32
|
作者
Ma, Rong-Hua [4 ]
Wang, Dung-An [3 ]
Hsueh, Tzu-Han [2 ]
Lee, Chia-Yen [1 ]
机构
[1] Natl Pingtung Univ Sci & Technol, Dept Mat Engn, Pingtung 912, Taiwan
[2] Da Yeh Univ, Dept Mech & Automat Engn, Changhua 515, Taiwan
[3] Natl Chung Hsing Univ, Inst Precis Engn, Taichung 402, Taiwan
[4] Chinese Mil Acad, Dept Mech Engn, Kaohsiung 830, Taiwan
关键词
cantilever; flow direction; flow sensor; MEMS; temperature compensation; SENSOR; PROBE;
D O I
10.3390/s90705460
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study develops a MEMS-based low-cost sensing platform for sensing gas flow rate and flow direction comprising four silicon nitride cantilever beams arranged in a cross-form configuration, a circular hot-wire flow meter suspended on a silicon nitride membrane, and an integrated resistive temperature detector (RTD). In the proposed device, the flow rate is inversely derived from the change in the resistance signal of the flow meter when exposed to the sensed air stream. To compensate for the effects of the ambient temperature on the accuracy of the flow rate measurements, the output signal from the flow meter is compensated using the resistance signal generated by the RTD. As air travels over the surface of the cross-form cantilever structure, the upstream cantilevers are deflected in the downward direction, while the downstream cantilevers are deflected in the upward direction. The deflection of the cantilever beams causes a corresponding change in the resistive signals of the piezoresistors patterned on their upper surfaces. The amount by which each beam deflects depends on both the flow rate and the orientation of the beam relative to the direction of the gas flow. Thus, following an appropriate compensation by the temperature-corrected flow rate, the gas flow direction can be determined through a suitable manipulation of the output signals of the four piezoresistors. The experimental results have confirmed that the resulting variation in the output signals of the integrated sensors can be used to determine not only the ambient temperature and the velocity of the air flow, but also its direction relative to the sensor with an accuracy of +/- 7.5 degrees error.
引用
收藏
页码:5460 / 5476
页数:17
相关论文
共 50 条
  • [41] MEMS FLOW SENSOR CAPABLE OF MEASURING MULTI-VITAL SIGNS OF RESPIRATION, HEART RATE, AND BODY TEMPERATURE
    Hasegawa, Yoshihiro
    Lee, Seunghyeon
    Matsushima, Miyoko
    Hasegawa, Shin
    Kawabe, Tsutomu
    Shikida, Mitsuhiro
    2021 21ST INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2021, : 691 - 694
  • [42] Hematocrit-insensitive Absolute Blood Flow Rate Measurement in 0.5-mm-diameter Flow Channel Using MEMS-based Laser Doppler Velocimeter with Signal Modification for Detecting Beat Frequency from Broad Power Spectrum
    Morita, Nobutomo
    Iwasaki, Wataru
    Nogami, Hirofumi
    Nakashima, Fumiya
    Higurashi, Eiji
    Sawada, Renshi
    SENSORS AND MATERIALS, 2018, 30 (12) : 3009 - 3020
  • [43] Determination of flow-rate characteristics for pneumatic components using a quasi-isothermal tank with temperature compensation
    Wang, Tao
    Peng, Guangzheng
    Kagawa, Toshiharu
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (06)
  • [44] GENERIC TEMPERATURE COMPENSATION SCHEME FOR CMOS-MEMS RESONATORS BASED ON ARC-BEAM DERIVED ELECTRICAL STIFFNESS FREQUENCY PULLING
    Hsieh, I-Chieh
    Zheng, Hong-Sen
    Tsai, Chun-Pu
    Chen, Ting-Yi
    Li, Wei-Chang
    2023 IEEE 36TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, MEMS, 2023, : 1155 - 1158
  • [45] Thermo-flow and temperature sensing behaviour of graphene based on surface heat convection
    Al-Mumen, Haider
    Rao, Fubo
    Dong, Lixin
    Li, Wen
    MICRO & NANO LETTERS, 2013, 8 (10) : 681 - 685
  • [46] An Integrated Biological Analysis and Flow Rate Sensing for the Real-Time Detection of Carcinogen in Water Based on Co2+-Doped Optical Fibers
    Gao, Ran
    Ye, Jiansen
    Xin, Xiangjun
    IEEE SENSORS JOURNAL, 2020, 20 (04) : 1912 - 1921
  • [47] A flow rate on-line monitoring method for piezoelectric pump based on self-sensing circuit
    Jiang, Hong
    Wu, Guohui
    He, Lipeng
    Wang, Yuecheng
    Hu, Dianbin
    Zhang, Zheng
    Cheng, Guangming
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2022, 36 (05) : 2415 - 2423
  • [48] SINGLE-CHIP INTEGRATION OF CMOS COMPATIBLE MEMS TEMPERATURE/HUMIDITY AND HIGHLY SENSITIVE FLOW SENSORS FOR HUMAN THERMAL COMFORT SENSING APPLICATION
    Izhar
    Xu, Wei
    Tavakkoli, Hadi
    Cabot, Jose
    Zhao, Xu
    Duan, Mingzheng
    Lee, Yi-Kuen
    2021 21ST INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2021, : 1219 - 1222
  • [49] Cascaded bowknot-type taper based Mach-Zehnder interferometer for microfluidic flow rate sensing
    Sun, Zhiqiang
    Wu, Shuaijie
    Shuai, Shaojie
    Gong, Jiaqi
    Xiao, Yike
    Liu, Zexu
    Lang, Tingting
    Zhao, Chunliu
    Shen, Changyu
    OPTICAL FIBER TECHNOLOGY, 2019, 48 : 12 - 14
  • [50] CONSTRUCTAL DESIGN OF A NON-INVASIVE TEMPERATURE BASED MASS FLOW RATE SENSOR FOR ALGAE PHOTOBIOREACTORS
    Ribeiro, Kassiana
    Ordonez, Juan C.
    Vargas, Jose V. C.
    Mariano, Andre B.
    PROCEEDINGS OF THE ROMANIAN ACADEMY SERIES A-MATHEMATICS PHYSICS TECHNICAL SCIENCES INFORMATION SCIENCE, 2018, 19 : 279 - 284