Active non-contact tonometer for glaucoma detection

被引:0
|
作者
Han, YM [1 ]
Bryanston-Cross, PJ [1 ]
Lee, WK [1 ]
Hero, M [1 ]
机构
[1] Univ Warwick, Sch Engn, Coventry CV4 7AL, W Midlands, England
关键词
glaucoma; cornea; intra-ocular pressure (IOP); tonometer; resonance frequency; fibre optic lever sensor;
D O I
10.1117/12.482946
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Glaucoma is an increasingly common cause of visual impairment, and in some cases causes blindness. The approach to develop a low cost and non-contact tonometer for the detection of glaucoma, to replace the Goldmann tonometer used worldwide, is presented in this paper. The new tonometer exploits the vibration property of the cornea - the resonance frequency of the cornea rises with increasing intra-ocular pressure (IOP). An audio frequency signal is used to vibrate the cornea of the eye, the vibration of the cornea is measured using a fibre optic lever probe, and then the IOP can be calculated from the detected resonance frequency of the cornea. The initial PC-version experiment system of the new tonometer has been demonstrated and preliminary testing has been performed, showing a suitable sensitivity in detecting the resonance frequency against the IOP using both the simulated-eye model and the pig's eye. The initial system has been improved to be suitable for greater than 15mm detecting distance, and the measurement of vibrations of human cornea in-vivo has been carried out. Work is now focusing on increasing the sensitivity of the fibre probe, and reducing the measuring time to less than I second.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [1] NON-CONTACT TONOMETER
    不详
    MEDICAL LETTER ON DRUGS AND THERAPEUTICS, 1977, 19 (22): : 91 - 92
  • [2] EXPERIENCES WITH NON-CONTACT TONOMETER
    DITTMAR, P
    WEINBERG, M
    LIEGL, O
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1975, 167 (01) : 137 - 141
  • [3] AO - NON-CONTACT TONOMETER
    SORENSEN, PN
    ACTA OPHTHALMOLOGICA, 1975, : 32 - 33
  • [4] PRACTICAL EXPERIENCE WITH THE NON-CONTACT TONOMETER
    CLEMENS, S
    GREWE, R
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1988, 193 (04) : 443 - 443
  • [5] A-O NON-CONTACT TONOMETER
    JUNGE, J
    OPHTHALMOLOGICA, 1977, 175 (01) : 32 - 33
  • [6] CLINICAL EVALUATION OF NON-CONTACT TONOMETER
    WITTENBERG, S
    JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 1977, 48 (02) : 196 - 207
  • [7] EVALUATION OF AO NON-CONTACT TONOMETER
    POLSE, KA
    JAUREGUI, MJ
    MCCLENDON, J
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1972, 49 (10): : 881 - +
  • [8] CLINICAL TONOMETRIC MEASUREMENTS WITH NON-CONTACT TONOMETER
    AUGSBURG.A
    POLASKY, M
    WALBY, M
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1973, 50 (09): : 743 - 743
  • [9] EVALUATION OF THE KEELER PULSAIR NON-CONTACT TONOMETER
    SPONSEL, WE
    KAUFMAN, PL
    STRINDEN, TI
    DEPAUL, KL
    BOWES, HN
    OLANDER, KW
    BARNEBEY, HS
    ACTA OPHTHALMOLOGICA, 1989, 67 (05): : 567 - 572
  • [10] NON-CONTACT TONOMETER - ITS VALUE AND LIMITATIONS
    SHIELDS, MB