Mercury(II) sensing based on the quenching of fluorescence of CdS-dendrimer nanocomposites

被引:44
作者
Campos, Bruno B. [1 ]
Algarra, Manuel [2 ]
Alonso, Beatriz [3 ]
Casado, Carmen M. [3 ]
Esteves da Silva, Joaquim C. G. [1 ]
机构
[1] Univ Porto, Ctr Invest Quim, Dept Quim, Fac Ciencias, P-4169007 Oporto, Portugal
[2] Univ Porto, Ctr Geol, Fac Ciencias, P-4169007 Oporto, Portugal
[3] Univ Autonoma Madrid, Dept Quim Inorgan, E-28049 Madrid, Spain
关键词
CAPPED QUANTUM DOTS; AQUEOUS-SOLUTION; HG2+; SENSORS; PROBES; ION; NANOPARTICLES; RECEPTOR;
D O I
10.1039/b914302e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A chemical sensor for mercury(II) (Hg(II)) was developed based on the quenching of the fluorescence of cadmium sulfide (CdS) quantum dots (QDs) coated with polypropylenimine tetrahexacontaamine dendrimer ( DAB) generation 5, CdS-DAB nanocomposites. The synthesis and characterization of CdS-DAB nanocomposites by means of EDXA, SEM and steady state luminescence is described. Macroscopic spherical structures are observed by electronic microscopy and the wavelength for the maximum fluorescence emission occurs at 535 nm (excitation at 351 nm). Stern-Volmer plots show a linear response in the range of 1 x 10(-6) to 1 x 10(-5) M with a quenching constant (K-sv) of 1.5 x 10(5) M-1. A parallel factor (PARAFAC) analysis model confirmed that Hg( II) alone provokes quenching of the fluorescence. Cu(II) and Pb(II) also quench the fluorescence of CdS-DAB nanocomposites, with a K-sv = 1.9 x 10(5) M-1 and K-sv = 2.2 x 10(-4) M-1, respectively, and Cd(II), Zn(II), Co(II) and Ni(II) have no effect. Ionic strength, in the range from 1.25 x 10(-3) up to 2 M, provokes a shift in the wavelength of the maximum of the emission spectra, from 482 to 677 nm.
引用
收藏
页码:2447 / 2452
页数:6
相关论文
共 46 条
[1]   Ultrasensitive Pb2+ detection by glutathione-capped quantum dots [J].
Ali, Emril Mohamed ;
Zheng, Yuangang ;
Yu, Hsiao-hua ;
Ying, Jackie Y. .
ANALYTICAL CHEMISTRY, 2007, 79 (24) :9452-9458
[2]  
Ballauff M, 2001, TOP CURR CHEM, V212, P177
[3]   Dendrimers in solution: Insight from theory and simulation [J].
Ballauff, M ;
Likos, CN .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (23) :2998-3020
[4]   Triethanolamine-capped CdSe quantum dots as fluorescent sensors for reciprocal recognition of mercury (II) and iodide in aqueous solution [J].
Bin Shang, Zhuo ;
Wang, Yu ;
Jin, Wei Jun .
TALANTA, 2009, 78 (02) :364-369
[5]   PARAFAC. Tutorial and applications [J].
Bro, R .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 38 (02) :149-171
[6]   Semiconductor nanocrystals as fluorescent biological labels [J].
Bruchez, M ;
Moronne, M ;
Gin, P ;
Weiss, S ;
Alivisatos, AP .
SCIENCE, 1998, 281 (5385) :2013-2016
[7]   Highly selective chromogenic and redox or fluorescent sensors of Hg2+ in aqueous environment based on 1,4-disubstituted azines [J].
Caballero, A ;
Martínez, R ;
Lloveras, V ;
Ratera, I ;
Vidal-Gancedo, J ;
Wurst, K ;
Tárraga, A ;
Molina, P ;
Veciana, J .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (45) :15666-15667
[8]   A novel fluorescent array for mercury (II) ion in aqueous solution with functionalized cadmium selenide nanoclusters [J].
Chen, Jinlong ;
Gao, YingChun ;
Xu, ZhiBing ;
Wu, GenHua ;
Chen, YouCun ;
Zhu, ChangQing .
ANALYTICA CHIMICA ACTA, 2006, 577 (01) :77-84
[9]   Functionalized cadmium sulfide quantum dots as fluorescence probe for silver ion determination [J].
Chen, JL ;
Zhu, CQ .
ANALYTICA CHIMICA ACTA, 2005, 546 (02) :147-153
[10]  
Duan JL, 2009, NANO RES, V2, P61, DOI [10.1007/S12274-009-9004-0, 10.1007/s12274-009-9004-0]