Accurate Fiducial Point Detection Using Haar Wavelet for Beat-by-Beat Blood Pressure Estimation

被引:11
作者
Singla, Muskan [1 ]
Azeemuddin, Syed [1 ]
Sistla, Prasad [2 ]
机构
[1] Int Inst Informat Technol, Ctr VLSI & Embedded Syst Technol, Hyderabad 500032, India
[2] Care Hosp, Care Fdn, Hyderabad 500034, India
关键词
Adaptive algorithm; blood pressure; detection algorithm; electrocardiography; feature extraction; photoplethysmography; regression analysis; signal processing; wavelet transforms; PULSE TRANSIT-TIME; ECG; PPG;
D O I
10.1109/JTEHM.2020.3000327
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pulse Arrival Time (PAT) derived from Electrocardiogram (ECG) and Photoplethysmogram (PPG) for cuff-less Blood Pressure (BP) measurement has been a contemporary and widely accepted technique. However, the features extracted for it are conventionally from an isolated pulse of ECG and PPG signals. As a result, the estimated BP is intermittent. Objective: This paper presents feature extraction from each beat of ECG and PPG signals to make BP measurements uninterrupted. These features are extracted by employing Haar transformation to adaptively attenuate measurement noise and improve the fiducial point detection precision. Method: the use of only PAT feature as an independent variable leads to an inaccurate estimation of either Systolic Blood Pressure (SBP) or Diastolic Blood Pressure (DBP) or both. We propose the extraction of supplementary features that are highly correlated to physiological parameters. Concurrent data was collected as per the Association for the Advancement of Medical Instrumentation (AAMI) guidelines from 171 human subjects belonging to diverse age groups. An Adaptive Window Wavelet Transformation (AWWT) technique based on Haar wavelet transformation has been introduced to segregate pulses. Further, an algorithm based on log-linear regression analysis is developed to process extracted features from each beat to calculate BP. Results: The mean error of 0.43 and 0.20 mmHg, mean absolute error of 4.6 and 2.3 mmHg, and Standard deviation of 6.13 and 3.06 mmHg is achieved for SBP and DBP respectively. Conclusions: The features extracted are highly precise and evaluated BP values are as per the AAMI standards. Clinical Impact: This continuous real-time BP monitoring technique can be useful in the treatment of hypertensive and potential-hypertensive subjects.
引用
收藏
页数:11
相关论文
共 42 条
[1]   Estimating Correlation between Arterial Blood Pressure and Photoplethysmograph [J].
Abhay, Theertha ;
Kayalvizhi, N. ;
Gini, Rolant J. .
16TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2017, 61 :47-52
[2]  
American National Standard for Electronic or Automated Sphygmomanometers, 2002, SP102002 ANSIAAMI
[3]  
[Anonymous], 2013, 8106022013 ISO
[4]  
[Anonymous], 2014, IEEE Standard 1708-2014
[5]  
[Anonymous], 2015, Global Health Observatory data repository: Household air pollution
[6]   Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review [J].
Biswas, Dwaipayan ;
Simoes-Capela, Neide ;
Van Hoof, Chris ;
Van Helleputte, Nick .
IEEE SENSORS JOURNAL, 2019, 19 (16) :6560-6570
[7]   Continuous and Noninvasive Measurement of Systolic and Diastolic Blood Pressure by One Mathematical Model with the Same Model Parameters and Two Separate Pulse Wave Velocities [J].
Chen, Yan ;
Wen, Changyun ;
Tao, Guocai ;
Bi, Min .
ANNALS OF BIOMEDICAL ENGINEERING, 2012, 40 (04) :871-882
[8]   Noninvasive cuffless blood pressure estimation using pulse transit time and Hilbert-Huang transform [J].
Choi, Younhee ;
Zhang, Qiao ;
Ko, Seokbum .
COMPUTERS & ELECTRICAL ENGINEERING, 2013, 39 (01) :103-111
[9]   Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio [J].
Ding, Xiao-Rong ;
Zhang, Yuan-Ting ;
Liu, Jing ;
Dai, Wen-Xuan ;
Tsang, Hon Ki .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (05) :964-972
[10]  
Ding XR, 2015, IEEE ENG MED BIO, P398, DOI 10.1109/EMBC.2015.7318383