Long-term functional outcome of distal radius fractures is associated with early post-fracture bone stiffness of the fracture region: An HR-pQCT exploratory study

被引:8
作者
Heyer, F. L. [1 ,2 ,3 ]
de Jong, J. J. A. [4 ]
Willems, P. C. [5 ,6 ]
Arts, J. J. [5 ,6 ]
Bours, S. G. P. [7 ]
van Kuijk, S. M. J. [8 ]
Poeze, M. [1 ,2 ]
Geusens, P. P. [5 ,7 ,9 ]
van Rietbergen, B. [10 ]
van den Bergh, J. P. [1 ,3 ,7 ,9 ]
机构
[1] Maastricht Univ, Res Sch NUTRIM, Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Surg, Maastricht, Netherlands
[3] VieCuri Med Ctr Venlo, Dept Internal Med, Venray, Netherlands
[4] Maastricht Univ, Med Ctr, Dept Radiol, Maastricht, Netherlands
[5] Maastricht Univ, Res Sch CAPHRI, Maastricht, Netherlands
[6] Maastricht Univ, Med Ctr, Dept Orthoped Surg, Maastricht, Netherlands
[7] Maastricht Univ, Med Ctr, Dept Rheumatol, Maastricht, Netherlands
[8] Maastricht Univ, Med Ctr, Dept Clin Epidemiol & Med Technol Assessment, Maastricht, Netherlands
[9] Hasselt Univ, Fac Med & Life Sci, Hasselt, Belgium
[10] Eindhoven Univ Technol, Fac Biomed Engn, Eindhoven, Netherlands
关键词
Fracture healing; Functional outcome; HR-pQCT; Finite element analysis; COMPUTED-TOMOGRAPHY; DISABILITY; DENSITY; PAIN;
D O I
10.1016/j.bone.2019.06.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Identifying determinants of long-term functional outcome after a distal radius fracture is challenging. Previously, we reported on the association between early HR-pQCT measurements and clinical outcome 12 weeks after a conservatively treated distal radius fracture. We extended the follow-up and assessed functional outcome after two years in relation to early HR-pQCT derived bone parameters. HR-pQCT scans of the fracture region were performed in 15 postmenopausal women with a distal radius fracture at 1-2 (baseline), 3-4 weeks and 26 months post-fracture. Additionally, the contralateral distal radius was scanned at baseline. Bone density, micro-architecture parameters and bone stiffness using micro-finite element analysis (FEA) were evaluated. During all visits, wrist pain and function were assessed using the patient-rated wrist evaluation questionnaire (PRWE), quantifying functional outcome with a score between 0 and 100. Two-year PRWE was associated with torsional and bending stiffness 3-4 weeks post-fracture (R-2: 0.49, p = 0.006 and R-2: 0.54, p = 0.003, respectively). In contrast, early micro-architecture parameters of the fracture region or contralateral bone parameters did not show any association with long-term outcome. This exploratory study indicates that HR-pQCT with mu FEA performed within four weeks after a distal radius fracture captures biomechanical fracture characteristics that are associated with long-term functional outcome and therefore could be a valuable early outcome measure in clinical trials and clinical practice.
引用
收藏
页码:510 / 516
页数:7
相关论文
共 26 条
[1]   Micro-Finite Element analysis will overestimate the compressive stiffness of fractured cancellous bone [J].
Arias-Moreno, Andres Julian ;
Ito, Keita ;
van Rietbergen, Bert .
JOURNAL OF BIOMECHANICS, 2016, 49 (13) :2613-2618
[2]   Fractures of the distal radius in low-demand elderly patients - Closed reduction of no value in 53 of 60 wrists [J].
Beumer, A ;
McQueen, MM .
ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (01) :98-100
[3]   Bone geometry and skeletal fragility [J].
Bouxsein M.L. ;
Karasik D. .
Current Osteoporosis Reports, 2006, 4 (2) :49-56
[4]  
Brink PRG, 2010, RICHTLIJN DISTALE RA, P1
[5]   Psychometric properties of the Patient Rated Wrist/Hand Evaluation - Dutch Language Version (PRWH/E-DLV) [J].
Brink, S. M. ;
Voskamp, E. G. ;
Houpt, P. ;
Emmelot, C. H. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (04) :556-557
[6]   Epidemiology of fractures in the United Kingdom 1988-2012: Variation with age, sex, geography, ethnicity and socioeconomic status [J].
Curtis, Elizabeth M. ;
van der Velde, Robert ;
Moon, Rebecca J. ;
van den Bergh, Joop P. W. ;
Geusens, Piet ;
de Vries, Frank ;
van Staa, Tjeerd P. ;
Cooper, Cyrus ;
Harvey, Nicholas C. .
BONE, 2016, 87 :19-26
[7]   Fracture Repair in the Distal Radius in Postmenopausal Women: A Follow-Up 2 Years Postfracture Using HRpQCT [J].
de Jong, Joost J. A. ;
Heyer, Frans L. ;
Arts, Jacobus J. C. ;
Poeze, Martijn ;
Keszei, Andras P. ;
Willems, Paul C. ;
van Rietbergen, Bert ;
Geusens, Piet P. ;
van den Bergh, Joop P. W. .
JOURNAL OF BONE AND MINERAL RESEARCH, 2016, 31 (05) :1114-1122
[8]   Effect of a Cast on Short-Term Reproducibility and Bone Parameters Obtained from HR-pQCT Measurements at the Distal End of the Radius [J].
de Jong, Joost J. A. ;
Arts, Jacobus J. ;
Meyer, Ursina ;
Willems, Paul C. ;
Geusens, Piet P. ;
van den Bergh, Joop P. W. ;
van Rietbergen, Bert .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (05) :356-362
[9]   Assessment of the healing process in distal radius fractures by high resolution peripheral quantitative computed tomography [J].
de Jong, Joost J. A. ;
Willems, Paul C. ;
Arts, Jacobus J. ;
Bours, Sandrine G. P. ;
Brink, Peter R. G. ;
van Geel, Tineke A. C. M. ;
Poeze, Martijn ;
Geusens, Piet P. ;
van Rietbergen, Bert ;
van den Bergh, Joop P. W. .
BONE, 2014, 64 :65-74
[10]   Optimizing fracture prevention: the fracture liaison service, an observational study [J].
Eekman, D. A. ;
van Helden, S. H. ;
Huisman, A. M. ;
Verhaar, H. J. J. ;
Bultink, I. E. M. ;
Geusens, P. P. ;
Lips, P. ;
Lems, W. F. .
OSTEOPOROSIS INTERNATIONAL, 2014, 25 (02) :701-709