Once-daily ciclesonide via metered-dose inhaler: Similar efficacy and safety with or without a spacer

被引:5
作者
Engelstaetter, Renate [1 ]
Szlavik, M. [2 ]
Gerber, Claudia [1 ]
Beck, Ekkehard [3 ]
机构
[1] Nycomed GmbH, D-78467 Constance, Germany
[2] Kaposi Mor Cty & Teaching Hosp, Clin Paediat, Hosp Chest Dis, Dept Paediat, H-7257 Mosdos, Hungary
[3] Inst Gesundheitsforderung GmbH, D-15562 Rudersdorf, Germany
关键词
Ciclesonide; Metered-dose inhaler; Spacer device; Asthma; FLUTICASONE PROPIONATE; PHARMACOKINETICS; BUDESONIDE; CHILDREN;
D O I
10.1016/j.rmed.2009.06.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Inhaled corticosteroids (ICS) are recommended as first-line treatment for adults and children with persistent asthma. The Global Initiative for Asthma recommends that patients taking medium- or high-dose ICS delivered by metered-dose inhalers (MDIs) should use a spacer device. Methods: This randomized, open-label, 12-week, non-inferiority study compared the efficacy and safety of ciclesonide 160 mu g once daily delivered via hydrofluoroalkane-MDI alone (CIC160) or with a spacer (either an AeroChamber Plus [CIC160P] or an AeroChamber MAX [CIC160M]) in patients with persistent asthma. The primary efficacy variable was change in forced expiratory volume in 1 s (FEV1) from baseline to study end. Results: Significant improvements in FEV1 were observed from baseline to study end in each treatment group; least squares mean change from baseline ranged between 0.32 and 0.34L in the per-protocol (PP) analysis and similar results were observed for the intention-to-treat (ITT) analysis (p < 0.0001 for all). Non-inferiority of CIC160P and CIC160M to CIC160 was observed for both PP and ITT populations (p < 0.0001 [one-sided]). In all. groups, daily asthma symptom scores were reduced to 0 and significant reductions were observed in rescue medication use at study end (p < 0.0001 versus baseline for at[). Ciclesonide was welt tolerated in all groups and no cases of oral candidiasis were reported. Morning serum cortisol. levels significantly increased in all groups from baseline to study end (p <= 0.0389), with no significant between-treatment differences. Conclusion: In patients with persistent asthma, ciclesonide was shown to have similar efficacy and tolerability when administered via MDI alone or with a spacer. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1643 / 1650
页数:8
相关论文
共 50 条
  • [21] Barriers to metered-dose inhaler/spacer use in Canadian pediatric emergency departments: A national survey
    Osmond, Martin H.
    Gazarian, Madlen
    Henry, Richard L.
    Clifford, Tammy J.
    Tetzlaff, Jennifer
    ACADEMIC EMERGENCY MEDICINE, 2007, 14 (11) : 1106 - 1113
  • [22] Evaluating Sex Differences in Efficacy, Safety and Pharmacokinetics in Patients Treated with Cannabis by a Metered-Dose Inhaler
    Aviram, Joshua
    Glezerman, Marek
    Hayam, Eytan
    Belobrov, Rostislav
    Procaccia, Shiri
    Meiri, David
    Eisenberg, Elon
    PHARMACEUTICALS, 2023, 16 (10)
  • [23] Efficacy and Safety of Salmeterol/Fluticasone Propionate Combination Delivered by the Diskus™ or Pressurised Metered-Dose Inhaler in Children with Asthma
    Teresa Bracamonte
    Uwe Schauer
    Andrzej Emeryk
    Alex Godwood
    Sima Balsara
    Clinical Drug Investigation, 2005, 25 : 1 - 11
  • [24] Metered-dose inhaler add-on devices: An in vitro evaluation of the BronchoAir inhaler and several spacer devices
    Steckel, H
    Muller, BW
    JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1998, 11 (03): : 133 - 142
  • [25] Fluticasone propionate/salmeterol hydrofluoroalkane via metered-dose inhaler with integrated dose counter: performance and patient satisfaction
    Sheth, K.
    Wasserman, R. L.
    Lincourt, W. R.
    Locantore, N. W.
    Carranza-Rosenzweig, J.
    Crim, C.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2006, 60 (10) : 1218 - 1224
  • [26] Salbutamol via metered-dose inhaler with Spacer versus nebulization for acute treatment of pediatric asthma in the emergency department
    Benito-Fernández, J
    González-Balenciaga, M
    Capapé-Zache, S
    Vázquez-Ronco, MA
    Mintegi-Raso, S
    PEDIATRIC EMERGENCY CARE, 2004, 20 (10) : 656 - 659
  • [27] Nebulization versus metered-dose inhaler and spacer in bronchodilator responsiveness testing: a retrospective study
    Lu, Rongli
    Li, Ying
    Hu, Chengping
    Pan, Pinhua
    Zhao, Qiaohong
    He, Ruoxi
    THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2023, 17
  • [28] The safety and clinical benefit of budesonide/formoterol pressurized metered-dose inhaler versus budesonide alone in children
    Berger, William E.
    Leflein, Jeffrey G.
    Geller, David E.
    Parasuraman, Bhash
    Miller, Christopher J.
    O'Brien, Christopher D.
    O'Dowd, Liza
    ALLERGY AND ASTHMA PROCEEDINGS, 2010, 31 (01) : 26 - 39
  • [29] Emitted doses of salbutamol pressurized metered-dose inhaler from five different plastic spacer devices
    Dubus, JC
    Dolovich, M
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2000, 14 (03) : 219 - 224
  • [30] Efficacy and Safety of Budesonide and Formoterol in One Pressurised Metered-Dose Inhaler in Adults and Adolescents with Moderate to Severe AsthmaA Randomised Clinical Trial
    Michael Noonan
    Lanny J. Rosenwasser
    Paula Martin
    Christopher D. O’Brien
    Liza O’Dowd
    Drugs, 2006, 66 : 2235 - 2254