Joint Gait Kinematic and Kinetic Analysis using Inertial Measurement Units and Plantar Pressure Sensor System

被引:3
作者
Dela Cruz, Michaela Anne A. [1 ]
Legaspi, Katrina Mae C. [1 ]
Marcelino, Raymund Miguel D. [1 ]
Rosete, Jan Ryan [1 ]
Sangalang, Danielle Anne R. [1 ]
Suarez, Consuelo G. [1 ]
Roxas, Edison A. [1 ]
Serrano, Kanny Krizzy D. [1 ]
dela Cruz, Angelo R. [1 ]
机构
[1] Univ Santo Tomas, Elect Engn Dept, Manila, Philippines
来源
2019 IEEE 11TH INTERNATIONAL CONFERENCE ON HUMANOID, NANOTECHNOLOGY, INFORMATION TECHNOLOGY, COMMUNICATION AND CONTROL, ENVIRONMENT, AND MANAGEMENT (HNICEM) | 2019年
关键词
angle; correlation; F-Scan System; gait; IMU; kinematics; kinetic; MATLAB; plantar pressure; peak pressure; regression;
D O I
10.1109/hnicem48295.2019.9072701
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Gait analysis is widely used in various fields of research, often associated in the field that concerns public health. The kinematic and kinetic analysis of a person's gait are the usual elements involved for the advancement of the topics involving this area but a relationship between the two are not often established or focused upon. The purpose of this study is to discover the correlation between the kinetic and kinematic elements of a person's gait with the use of wearable sensors such as IMUs and insole plantar pressure sensors. The sensors, alongside their corresponding software, were utilized to observe a person's gait based on gait cycles. The acquired data were viewed using MATLAB and is analyzed in terms of its plantar pressure and kinematic composition. Consequently, the results displayed the angular displacement and pressure distribution per leg and foot. Using Regression Learner app from MATLAB, a model is trained to test the validity of said model with a test subject. The Pearson's correlation coefficient of the actual and predicted waveforms ranged from 0.80 to 0.95. The system can also be used to aid in gait analysis and assessment by medical practitioners and by future researchers.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Using Inertial Measurement Units to Examine Selected Joint Kinematics in a Road Cycling Sprint: A Series of Single Cases
    Morbey, Simon
    Tronslien, Marius
    Kong, Kunho
    Chapman, Dale W.
    Netto, Kevin
    SENSORS, 2024, 24 (11)
  • [42] Concurrent Validation of 3D Joint Angles during Gymnastics Techniques Using Inertial Measurement Units
    Barreto, Joana
    Peixoto, Cesar
    Cabral, Silvia
    Williams, Andrew Mark
    Casanova, Filipe
    Pedro, Bruno
    Veloso, Antonio P.
    ELECTRONICS, 2021, 10 (11)
  • [43] Remote length measurement system using a single point laser distance sensor and an inertial measurement unit
    Duy Duong Pham
    Suh, Young Soo
    COMPUTER STANDARDS & INTERFACES, 2017, 50 : 153 - 159
  • [44] Active marker based kinematic and spatio-temporal gait measurement system using LabVIEW vision
    Kumar, Neelesh
    Kunju, Nissan
    Kumar, Amod
    Sohi, B. S.
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2010, 69 (08): : 600 - 605
  • [45] Validation of algorithms for calculating spatiotemporal gait parameters during continuous turning using lumbar and foot mounted inertial measurement units
    Kvist, Alexander
    Tinmark, Fredrik
    Bezuidenhout, Lucian
    Reimeringer, Mikael
    Conradsson, David Moulaee
    Franzen, Erika
    JOURNAL OF BIOMECHANICS, 2024, 162
  • [46] Rehabilitation outcome in patients with obstructive sleep apnea syndrome using wearable inertial sensor for gait analysis
    Pagano, Gaetano
    Aliani, Maria
    Genco, Maddalena
    Coccia, Armando
    Proscia, Vito
    Cesarelli, Mario
    D'Addio, Giovanni
    2022 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA 2022), 2022,
  • [47] Development of Gait Analysis System Based on Continuous Plantar Images Obtained Using CaTTaP Device
    Iijima, Yuka
    Shiina, Takayuki
    Ishikawa, Takumi
    Takemura, Hiroshi
    Mizoguchi, Hiroshi
    ADVANCED BIOMEDICAL ENGINEERING, 2015, 4 : 119 - 125
  • [48] Effect on kinematic gait variables of two methods of inertial measurement unit sensor attachment to the extremities of horses under controlled conditions of treadmill exercise in sound horses at the walk and trot: A pilot study
    Seghers, Tamara
    Maninchedda, Ugo E.
    Vidondo, Beatriz
    Ramseyer, Alessandra
    Cruz, Antonio M.
    PFERDEHEILKUNDE, 2018, 34 (04): : 333 - 340
  • [49] Validity Evaluation of an Inertial Measurement Unit (IMU) in Gait Analysis Using Statistical Parametric Mapping (SPM)
    Park, Sangheon
    Yoon, Sukhoon
    SENSORS, 2021, 21 (11)
  • [50] Infant trunk posture and arm movement assessment using pressure mattress, inertial and magnetic measurement units (IMUs)
    Rihar, Andraz
    Mihelj, Matjaz
    Pasic, Jure
    Kolar, Janko
    Munih, Marko
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11