Feasibility of Day Surgery for Cochlear Implantation under Conscious Sedation with Same-Day Fitting

被引:9
作者
Aldhafeeri, Ahmad M. [1 ]
Saleh, Shaza [2 ]
Almuhawas, Fida [2 ]
Hagr, Abdulrahman [2 ]
机构
[1] Hafr Albaten Cent Hosp, Dept Otolaryngol, Hafr Albaten, Saudi Arabia
[2] King Saud Univ, King Saud Univ Med City, King Abdullah Ear Specialist Ctr, Riyadh, Saudi Arabia
关键词
Cochlear implant; local anesthesia; early fitting; LOCAL-ANESTHESIA; ACTIVATION;
D O I
10.5152/iao.2020.8208
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
OBJECTIVES: To evaluate the feasibility of performing cochlear implantation under conscious sedation (CS) as day surgery with same-day fitting. MATERIALS and METHODS: All patients underwent cochlear implantation under CS between November 2017 and April 2018. The data collected included demographic information, preoperative clinical characteristics, surgical details, postoperative fitting information, and side effects, if any. RESULTS: Nine patients had 11 cochlear implants (CIs) placed under CS (2 patients received bilateral CIs). One patient's data were excluded from the audiological results because conversion to general anesthesia (GA) was necessary. One patient (11%) vomited just before the end of the procedure. Seven patients had uneventful procedures. Eight (88%) patients were discharged home the same day. There was a statistically significant difference in recovery time between the CS group and the GA group (t=-2.26, df=12, p<0.05). In the CS group, there was no statistically significant change in the maximum comfortable loudness level for all electrodes from the day of the surgery to the following day. However, there was a statistically significant difference in the threshold levels of all electrodes from the day of the surgery to the following day (Z=-2.04, N=120, p<0.05). Further analysis revealed a statistically significant difference in the four most apical electrodes (Z=-3.496, N=40, p<0.0001), but not in the middle or basal electrodes. CONCLUSION: Cochlear implantation can be performed under CS with careful patient selection. This approach facilitates same-day fitting and day surgery by minimizing comorbidity.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 15 条
[11]   Effect of Surgical Technique on Electrode Impedance After Cochlear Implantation [J].
Jia, Huan ;
Venail, Frederic ;
Piron, Jean-Pierre ;
Batrel, Charlene ;
Pelliccia, Pierfrancesco ;
Artieres, Francoise ;
Uziel, Alain ;
Mondain, Michel .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2011, 120 (08) :529-534
[12]   Differences in the impedance of cochlear implant devices within 24 hours of their implantation [J].
Lin, David Po-Yi ;
Chen, Joshua Kuang-Chao ;
Tung, Tao-Hsin ;
Li, Lieber Po-Hung .
PLOS ONE, 2019, 14 (09)
[13]  
Mawby T A R, 2014, Cochlear Implants Int, V15, P109, DOI 10.1179/1754762813Y.0000000056
[14]   Postimplantation Changes of Electrophysiological Parameters in Patients with Cochlear Implants [J].
Molisz, Andrzej ;
Zarowski, Andrzej ;
Vermeiren, Annelies ;
Theunen, Tinne ;
De Coninck, Liesbeth ;
Siebert, Janusz ;
Offeciers, Erwin F. .
AUDIOLOGY AND NEURO-OTOLOGY, 2015, 20 (04) :222-228
[15]  
Vaid Neelam, 2016, Cochlear Implants Int, V17, P207