Development of contrast digital mammography

被引:100
作者
Skarpathiotakis, M
Yaffe, MJ [1 ]
Bloomquist, AK
Rico, D
Muller, S
Rick, A
Jeunehomme, F
机构
[1] Univ Toronto, Dept Med Biophys, Sunnybrook & Womens Coll, Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[2] GE Med Syst SA, Breast Imaging Adv Studies, F-78533 Buc, France
关键词
D O I
10.1118/1.1510128
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Development of breast tumors is often accompanied by angiogenesis-the formation of new blood vessels. It is possible to image the effects of this process by tracking the uptake and washout of contrast agents in the vicinity of a lesion. In this article, a method for carrying out contrast subtraction mammography on a full-field digital mammography unit is described. Spectral measurements and modeling were performed to optimize the choice of x-ray target, kilovoltage and x-ray beam filtration for contrast digital mammography (CDM) on an available digital mammography system. Phantom studies were carried out to determine the sensitivity of CDM to iodine. Detection' of iodine area densities of 0.3 mg/cm(2) is possible for a circular object with a radius of 1.3 mm, which allows detection of uptake levels in the breast typically seen with cancer and some benign breast conditions. It was found that with a molybdenum anode x-ray tube, copper filtration could be used to effectively shape the x-ray spectrum to maximize the proportion of x rays with energies above the k edge of iodine. Simple logarithmic subtraction was found to be adequate in suppressing background signals dependent on the x-ray beam intensity and background thickness of the breast. The total x-ray dose from the procedure ranges between 1 and 3 mGy, similar to that from a conventional single view film mammogram. A clinical pilot study is currently being carried out to evaluate this technique. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:2419 / 2426
页数:8
相关论文
共 29 条
[1]   BREAST-LESIONS EXAMINED BY DIGITAL ANGIOGRAPHY - WORK IN PROGRESS [J].
ACKERMAN, LV ;
WATT, AC ;
SHETTY, P ;
FLYNN, MJ ;
BURKE, M ;
KAMBOURIS, A ;
FINE, G ;
WILDERMAN, S .
RADIOLOGY, 1985, 155 (01) :65-68
[2]   Normalized glandular dose (DgN) coefficients for arbitrary x-ray spectra in mammography: Computer-fit values of Monte Carlo derived data [J].
Boone, JM .
MEDICAL PHYSICS, 2002, 29 (05) :869-875
[3]  
Boone JM, 2000, RADIOLOGY, V217, P346
[4]  
*CAN PHARM ASS, 1982, COMP PHARM SPEC
[5]  
*CAN PHARM ASS, 1997, COMP PHARM SPEC
[6]   COMPUTED TOMOGRAPHIC MAMMOGRAPHY USING A CONVENTIONAL BODY SCANNER [J].
CHANG, CHJ ;
NESBIT, DE ;
FISHER, DR ;
FRITZ, SL ;
DWYER, SJ ;
TEMPLETON, AW ;
LIN, F ;
JEWELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (03) :553-558
[7]   Cone-beam volume CT mammographic imaging: feasibility study [J].
Chen, BA ;
Ning, RL .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :655-664
[8]  
DEAN PB, 1984, RADIOCONTRAST AGENTS, P497
[9]   OPTIMIZATION OF SPECTRAL SHAPE IN DIGITAL MAMMOGRAPHY - DEPENDENCE ON ANODE MATERIAL, BREAST THICKNESS, AND LESION TYPE [J].
FAHRIG, R ;
YAFFE, MJ .
MEDICAL PHYSICS, 1994, 21 (09) :1473-1481
[10]   Contrast-enhanced CT: Value for diagnosing local breast cancer recurrence after conservative treatment [J].
Hagay, C ;
Cherel, PJP ;
deMaulmont, CE ;
Plantet, MM ;
Gilles, R ;
Floiras, JLG ;
Garbay, JR ;
Pallud, CM .
RADIOLOGY, 1996, 200 (03) :631-638