Posterior lumbar interbody fusion - A biomechanical comparison, including a new threaded cage

被引:163
|
作者
Brodke, DS
Dick, JC
Kunz, DN
McCabe, R
Zdeblick, TA
机构
[1] UNIV WISCONSIN,CTR CLIN SCI,DIV ORTHOPAED SURG,MADISON,WI 53792
[2] COLORADO SPRINGS ORTHOPAED GRP,COLORADO SPRINGS,CO
[3] HENNEPIN CTY MED CTR,DEPT ORTHOPAED SURG,MINNEAPOLIS,MN
[4] UNIV WISCONSIN,DIV ORTHOPED SURG,MADISON,WI
关键词
biomechanics; posterior lumbar interbody fusion; spinal fusion;
D O I
10.1097/00007632-199701010-00005
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In vitro biomechanical testing was performed on eight lumbar calf spines. Objectives. To compare the initial stiffness of a standard method of posterior lumbar interbody fusion using structural autograft with the same procedure using additional posterior instrumentation. These constructs also were compared to a new titanium implant. Summary of Background Data. Posterior lumbar interbody fusion is gaining wide acceptance for the treatment of segmental spinal instability, spondylolisthesis, and discogenic pain. Many methods have been described, including use of autograft or allograft bone, in either structural or nonstructural form, with or without additional fixation. A new threaded titanium interbody implant has been designed to increase initial stability while allowing bony ingrowth for fusion. Methods. Eight lumbar calf spines were subjected to axial compression, sagittal moments (flexion-extension), and axial torque while displacement was measured. Stiffness was calculated from the load displacement curves for each construct under each load pattern. Results. The posterior lumbar interbody fusion by bone graft alone was the least stiff construct of all modes tested. In two of eight specimens the bone graft dislodged posteriorly into the canal during torsional testing. The titanium interbody implant was similar in stiffness to the bone graft posterior lumbar interbody fusion with posterior instrumentation group in all three modes. They were both significantly stiffer than the normal spine, the destabilized spine, and the posterior lumbar interbody fusion by bone graft alone (P < 0.05). Conclusions. In this model, the posterior lumbar interbody fusion with bone graft alone had less initial stiffness than that of the intact spine. The addition of posterior instrumentation or interbody implants can increase initial stiffness significantly.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 50 条
  • [31] Posterior lumbar interbody fusion
    Oliver, MD
    Cahill, DW
    Hajjar, MV
    TECHNIQUES IN NEUROSURGERY, 2001, 7 (02): : 127 - 139
  • [32] Posterior lumbar interbody fusion
    Clavel-Escribano, M
    Robles-Balibrea, A
    Clavel-Laria, P
    Robles-Cano, V
    Puertas-García-Sandoval, P
    Laria-Fernández, C
    NEUROCIRUGIA, 2001, 12 (05): : 447 - 455
  • [33] In vitro biomechanical comparison of an anterior and anterolateral lumbar plate with posterior fixation following single-level anterior lumbar interbody fusion
    Johnson, Wesley M.
    Nichols, Tann A.
    Jethwani, Deepika
    Guiot, Bernard H.
    JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (03) : 332 - 335
  • [34] A comparison of the biomechanical responses of lumbar interbody fusion cage combined with posterior fixation systems made of rigid versus semi-rigid materials
    Fan, Wei
    Yang, Song
    Zhang, Dong-Yao
    Sun, Zhen-Ya
    Sui, Huai-Ming
    Chen, Jie
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2025,
  • [35] Posterior lumbar interbody fusion
    Harrington, T
    Javedan, S
    NEUROSURGERY QUARTERLY, 2000, 10 (03) : 228 - 238
  • [36] A comparison of posterior lumbar interbody fusion and transforaminal lumbar interbody fusion: a literature review and meta-analysis
    Zhang, Qunhu
    Yuan, Zhen
    Zhou, Min
    Liu, Huan
    Xu, Yong
    Ren, Yongxin
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [37] A comparison of posterior lumbar interbody fusion and transforaminal lumbar interbody fusion: a literature review and meta-analysis
    Qunhu Zhang
    Zhen Yuan
    Min Zhou
    Huan Liu
    Yong Xu
    Yongxin Ren
    BMC Musculoskeletal Disorders, 15
  • [38] Biomechanical comparison of instrumented posterior lumbar interbody fusion with one or two cages by finite element analysis
    Chiang, Ming-Fu
    Zhong, Zheng-Cheng
    Chen, Chen-Sheng
    Cheng, Cheng-Kung
    Shih, Shih-Liang
    SPINE, 2006, 31 (19) : E682 - E689
  • [39] Risk Factors for Posterior Cage Migration after Lumbar Interbody Fusion Surgery
    Lee, Dong-Yeong
    Park, Young-Jin
    Song, Sang-Youn
    Jeong, Soon-Taek
    Kim, Dong-Hee
    ASIAN SPINE JOURNAL, 2018, 12 (01) : 59 - 68
  • [40] Dislodgment Effects of Different Cage Arrangements in Posterior Lumbar Interbody Fusion: A Finite Element Study
    Yang, Shih-Chieh
    Wu, Chih-Lin
    Tu, Yuan-Kun
    Liu, Pao-Hsin
    BIOENGINEERING-BASEL, 2024, 11 (06):