Posterior lumbar interbody fusion - A biomechanical comparison, including a new threaded cage

被引:163
|
作者
Brodke, DS
Dick, JC
Kunz, DN
McCabe, R
Zdeblick, TA
机构
[1] UNIV WISCONSIN,CTR CLIN SCI,DIV ORTHOPAED SURG,MADISON,WI 53792
[2] COLORADO SPRINGS ORTHOPAED GRP,COLORADO SPRINGS,CO
[3] HENNEPIN CTY MED CTR,DEPT ORTHOPAED SURG,MINNEAPOLIS,MN
[4] UNIV WISCONSIN,DIV ORTHOPED SURG,MADISON,WI
关键词
biomechanics; posterior lumbar interbody fusion; spinal fusion;
D O I
10.1097/00007632-199701010-00005
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In vitro biomechanical testing was performed on eight lumbar calf spines. Objectives. To compare the initial stiffness of a standard method of posterior lumbar interbody fusion using structural autograft with the same procedure using additional posterior instrumentation. These constructs also were compared to a new titanium implant. Summary of Background Data. Posterior lumbar interbody fusion is gaining wide acceptance for the treatment of segmental spinal instability, spondylolisthesis, and discogenic pain. Many methods have been described, including use of autograft or allograft bone, in either structural or nonstructural form, with or without additional fixation. A new threaded titanium interbody implant has been designed to increase initial stability while allowing bony ingrowth for fusion. Methods. Eight lumbar calf spines were subjected to axial compression, sagittal moments (flexion-extension), and axial torque while displacement was measured. Stiffness was calculated from the load displacement curves for each construct under each load pattern. Results. The posterior lumbar interbody fusion by bone graft alone was the least stiff construct of all modes tested. In two of eight specimens the bone graft dislodged posteriorly into the canal during torsional testing. The titanium interbody implant was similar in stiffness to the bone graft posterior lumbar interbody fusion with posterior instrumentation group in all three modes. They were both significantly stiffer than the normal spine, the destabilized spine, and the posterior lumbar interbody fusion by bone graft alone (P < 0.05). Conclusions. In this model, the posterior lumbar interbody fusion with bone graft alone had less initial stiffness than that of the intact spine. The addition of posterior instrumentation or interbody implants can increase initial stiffness significantly.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 50 条
  • [21] Definition of cage subsidence in transforaminal lumbar interbody fusion (TLIF) approach and posterior lumbar interbody fusion (PLIF) approach - A systematic review
    Baig, Rehman Ali
    Quiceno, Esteban
    Soliman, Mohamed A. R.
    Aguirre, Alexander O.
    Okai, Bernard K.
    Kuo, Cathleen C.
    Francois, Hendrick B.
    Stockman, Isabelle
    Shah, Shashwat
    Levy, Hannon W.
    Khan, Asham
    Rho, Kyungduk
    Pollina, John
    Mullin, Jeffrey P.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2025, 133
  • [22] Comparison between posterior lumbar interbody fusion and transforaminal lumbar interbody fusion in the management of lumbar spondylolisthesis
    Katuch, V
    Grega, R.
    Knorovsky, K.
    Banoci, J.
    Katuchova, J.
    Sasala, M.
    Ivankova, H.
    Kapralova, P.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2021, 122 (09): : 653 - 656
  • [23] Effect of Elastic Modulus on Biomechanical Properties of Lumbar Interbody Fusion Cage
    Zhu, Yue
    Li, Fusheng
    Li, Shujun
    Hao, Yulin
    Yang, Rui
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2009, 25 (03) : 325 - 328
  • [24] Comparison of posterior lumbar interbody fusion with transforaminal lumbar interbody fusion for treatment of recurrent lumbar disc herniation: A retrospective study
    Li, Liqiang
    Liu, Yueju
    Zhang, Peng
    Lei, Tao
    Li, Jie
    Shen, Yong
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2016, 44 (06) : 1424 - 1429
  • [26] Biomechanical comparison of biodegradable lumbar interbody fusion cages
    Khodadadyan-Klostermann, C
    Kandziora, F
    Schnake, KJ
    Lewandrowski, KU
    Wise, D
    Weiler, A
    Haas, NP
    CHIRURG, 2001, 72 (12): : 1431 - 1438
  • [27] Comparison of the early results of transforaminal lumbar interbody fusion and posterior lumbar interbody fusion in symptomatic lumbar instability
    Sakeb, Najmus
    Ahsan, Kamrul
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (03) : 255 - 263
  • [28] Biomechanical comparison of the effects of anterior, posterior and transforaminal lumbar interbody fusion on vibration characteristics of the human lumbar spine
    Fan, Wei
    Guo, Li-Xin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (05) : 490 - 498
  • [29] Comparison of the early results of transforaminal lumbar interbody fusion and posterior lumbar interbody fusion in symptomatic lumbar instability
    Najmus SakebP
    Kamrul Ahsan
    Indian Journal of Orthopaedics, 2013, 47 : 255 - 263
  • [30] Comparison of posterior and transforaminal approaches to lumbar interbody fusion
    Humphreys, SC
    Hodges, SD
    Patwardhan, AG
    Eck, JC
    Murphy, RB
    Covington, LA
    SPINE, 2001, 26 (05) : 567 - 571