Gender Differences in Wear Rates for 28-vs 32-mm Ceramic Femoral Heads on Modern Highly Cross-linked Polyethylene at Midterm Follow-Up in Young Patients Undergoing Total Hip Arthroplasty

被引:10
作者
Stambough, Jeffrey B. [1 ]
Pashos, Gail [1 ]
Wu, Ningying [2 ]
Haynes, Jacob A. [1 ]
Martell, John M. [3 ]
Clohisy, John C. [1 ]
机构
[1] Washington Univ, Sch Med, Dept Orthopaed Surg, 660 South Euclid Ave,Campus Box 8233, St Louis, MO 63110 USA
[2] Washington Univ, Sch Med, Div Biostat, St Louis, MO 63110 USA
[3] Univ Chicago Med & Biol Sci, Orthopaed Biomed Inst, Dept Orthopaed Surg & Rehabil Med, Chicago, IL USA
关键词
highly cross-linked polyethylene; wear; gender differences; Martell method; total hip arthroplasty outcomes; RANDOMIZED CONTROLLED-TRIAL; CONVENTIONAL POLYETHYLENE; UNITED-STATES; TOTAL JOINT; HARRIS HIP; REPLACEMENT; OSTEOARTHRITIS; BEARING; KNEE; PERFORMANCE;
D O I
10.1016/j.arth.2015.10.024
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We report on the midterm linear and volumetric wear of highly cross-linked polyethylene (HXLPE) and survivorship of 2 prospective young total hip arthroplasty (THA) cohorts that differed by the size of ceramic femoral head used: 28 vs 32 mm. Methods: We prospectively analyzed 220 consecutive primary THAs in patients aged <= 50 years who received a cementless THA with a ceramic femoral head on HXLPE liner (C-HXLPE). There were 101 patients (46%) with 28-mm heads and 119 patients (54%) who received 32-mm heads at a mean follow-up of 5.5 years (range, 60-109 months). Wear was calculated using Martell Software. Results: The 28-mm C-HXLPE cohort demonstrated average linear and volumetric wear of 0.020 mm/y (standard deviation [SD], 0.074; 95% CI, 0.003-0.037) and 18.775 mm(3)/y (SD, 21.743; 95% CI, 13.773-23.778) compared with 0.032 mm/y (SD, 0.087; 95% CI, 0.013-0.050]) and 29.847 mm(3)/y (SD, 35.441; 95% CI, 22.294-37.401) in the 32-mm C-HXLPE group. Subgroup analysis by gender and head size discovered significantly greater wear in females with 32-mm heads compared with 28-mm heads in both linear (0.01, 95% CI = -0.014 to 0.033 vs 0.048, 95% CI = 0.022-0.074 mm/y, P = .004) and volumetric wear (14.11, 95% CI = 8.957-19.271] vs 29.71, 95% CI = 17.584-41.840] mm(3)/y, P = .009). We found a 96% (95% CI = 92.30%-97.94%]) survivorship by Kaplan-Meier analysis at minimum 5 years with no failures because of osteolysis. Conclusions: Ceramic on HXLPE demonstrates extremely low wear properties in young patients at midterm follow-up. We identified a gender-dependent difference in wear based on head size, with 32-mm heads being associated with increased wear in females. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:899 / 905
页数:7
相关论文
共 42 条
  • [1] Effect of Femoral Head Size on Metal-on-HXLPE Hip Arthroplasty Outcome in a Combined Analysis of Six National and Regional Registries
    Allepuz, Alex
    Havelin, Leif
    Barber, Thomas
    Sedrakyan, Art
    Graves, Stephen
    Bordini, Barbara
    Hoeffel, Daniel
    Cafri, Guy
    Paxton, Elizabeth
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A : 12 - 18
  • [2] TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY
    AMSTUTZ, HC
    THOMAS, BJ
    JINNAH, R
    KIM, W
    GROGAN, T
    YALE, C
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) : 228 - 241
  • [3] Total Hip Arthroplasty Using Highly Cross-Linked Polyethylene in Patients Younger Than 50 Years With Minimum 10-Year Follow-Up
    Babovic, Nikola
    Trousdale, Robert T.
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (05) : 815 - 817
  • [4] Stress fracture in military recruits: Gender differences in muscle and bone susceptibility factors
    Beck, TJ
    Ruff, CB
    Shaffer, RA
    Betsinger, K
    Trone, DW
    Brodine, SK
    [J]. BONE, 2000, 27 (03) : 437 - 444
  • [5] BELLAMY N, 1988, J RHEUMATOL, V15, P1833
  • [6] A PRELIMINARY EVALUATION OF THE DIMENSIONALITY AND CLINICAL IMPORTANCE OF PAIN AND DISABILITY IN OSTEOARTHRITIS OF THE HIP AND KNEE
    BELLAMY, N
    BUCHANAN, WW
    [J]. CLINICAL RHEUMATOLOGY, 1986, 5 (02) : 231 - 241
  • [7] The 2012 John Charnley Award: Clinical Multicenter Studies of the Wear Performance of Highly Crosslinked Remelted Polyethylene in THA
    Bragdon, Charles R.
    Doerner, Michael
    Martell, John
    Jarrett, Bryan
    Palm, Henrik
    Malchau, Henrik
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (02) : 393 - 402
  • [8] Callaghan John J, 2009, Iowa Orthop J, V29, P1
  • [9] A Double-Blind, Prospective, Randomized Controlled Trial Comparing Highly Cross-Linked and Conventional Polyethylene in Primary Total Hip Arthroplasty
    Calvert, George T.
    Devane, Peter A.
    Fielden, Jan
    Adams, Kathryn
    Horne, J. Geoffrey
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (04) : 505 - 510
  • [10] Continued Improved Wear with an Annealed Highly Cross-linked Polyethylene
    Capello, William N.
    D'Antonio, James A.
    Ramakrishnan, Rama
    Naughton, Marybeth
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (03) : 825 - 830