regional anaesthesia: mechanism of injury; ultrasonography: internal jugular; ultrasound structures: echogenicity; TIME 3-DIMENSIONAL ULTRASOUND; FACET JOINT INJECTION; BRACHIAL-PLEXUS BLOCK; REGIONAL ANESTHESIA; GUIDANCE-SYSTEM; VASCULAR ACCESS; LUMBAR PUNCTURE; TRACKING SYSTEM; CURVILINEAR ULTRASOUND; RANDOMIZED-CROSSOVER;
D O I
10.1111/anae.13921
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety.
引用
收藏
页码:889 / 904
页数:16
相关论文
共 135 条
[71]   Modelling and characterisation of a ultrasound-actuated needle for improved visibility in ultrasound-guided regional anaesthesia and tissue biopsy [J].
Kuang, Y. ;
Hilgers, A. ;
Sadiq, M. ;
Cochran, S. ;
Corner, G. ;
Huang, Z. .
ULTRASONICS, 2016, 69 :38-46
[72]   Fiber-needle Swept-source Optical Coherence Tomography System for the Identification of the Epidural Space in Piglets [J].
Kuo, Wen-Chuan ;
Kao, Meng-Chun ;
Chang, Kuang-Yi ;
Teng, Wei-Nung ;
Tsou, Mei-Yung ;
Chang, Yin ;
Ting, Chien-Kun .
ANESTHESIOLOGY, 2015, 122 (03) :585-594
[73]   Incidence of unintentional intraneural injection and postoperative neurological complications with ultrasound-guided interscalene and supraclavicular nerve blocks [J].
Liu, S. S. ;
YaDeau, J. T. ;
Shaw, P. M. ;
Wilfred, S. ;
Shetty, T. ;
Gordon, M. .
ANAESTHESIA, 2011, 66 (03) :168-174
[74]   Laser assisted ultrasound guided aspiration improves procedure time and reduces number of withdrawals [J].
Liu, S. -Y. ;
Liao, M. -Y. ;
Wei, T. -S. ;
Yang, C. -P. ;
Chen, L. -W. ;
Lin, S. -J. ;
Ding, Y. -S. ;
Chang, Y. -J. .
ULTRASONICS, 2008, 48 (08) :647-651
[75]   Evidence Basis for Ultrasound-Guided Block Characteristics Onset, Quality, and Duration [J].
Liu, Spencer S. .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2016, 41 (02) :205-220
[76]  
Lu HX, 2014, LECT NOTES COMPUT SC, V8674, P389, DOI 10.1007/978-3-319-10470-6_49
[77]   Evaluation of a novel needle guide for ultrasound-guided phantom vessel cannulation [J].
Luyet, C. ;
Hartwich, V. ;
Urwyler, N. ;
Schumacher, P. M. ;
Eichenberger, U. ;
Vogt, A. .
ANAESTHESIA, 2011, 66 (08) :715-720
[78]   Ultrasound-guided catheterisation of the subclavian vein: freehand vs needle-guided technique [J].
Maecken, T. ;
Heite, L. ;
Wolf, B. ;
Zahn, P. K. ;
Litz, R. J. .
ANAESTHESIA, 2015, 70 (11) :1242-1249
[79]   Interventional real-time ultrasound imaging with an integrated electromagnetic field generator [J].
Maerz, K. ;
Franz, A. M. ;
Seitel, A. ;
Winterstein, A. ;
Hafezi, M. ;
Saffari, A. ;
Bendl, R. ;
Stieltjes, B. ;
Meinzer, H-P. ;
Mehrabi, A. ;
Maier-Hein, L. .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (05) :759-768
[80]   Safe performance of peripheral regional anaesthesia: the significance of ultrasound guidance [J].
Marhofer, P. ;
Fritsch, G. .
ANAESTHESIA, 2017, 72 (04) :431-434