Comparison of chemometrics strategies for the spectroscopic monitoring of active pharmaceutical ingredients in chemical reactions

被引:5
|
作者
Thiel, Michel [1 ,4 ]
Sauwen, Nicolas [2 ]
Khamiakova, Tastiana [1 ]
Maes, Tor [3 ]
Govaerts, Bernadette [4 ]
机构
[1] Janssen Pharmaceut, Mfg & Appl Stat, Turnhoutseweg 30, B-2340 Beerse, Belgium
[2] Open Analyt NV, Jupiterstr 20, B-2600 Antwerp, Belgium
[3] Janssen Pharmaceut, API Small Mol Dev, Turnhoutseweg 30, B-2340 Beerse, Belgium
[4] UCLouvain, Inst Stat Biostat & Actuarial Sci ISBA, Louvain Inst Data Anal & Modeling Econ & Stat LID, Voie Roman Pays 20,Bte L1-04-01, B-1348 Louvain La Neuve, Belgium
关键词
Process monitoring; Spectroscopy; NMF; MCR; PCA; PLS; PAT;
D O I
10.1016/j.chemolab.2021.104273
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The Process Analytical Technology (PAT) initiative promoted by the Food and Drug Administration (FDA) encourages pharmaceutical companies to increase the use of new analytical technologies to perform constant monitoring of the critical quality attributes (CQA), allowing a better understanding and a better control of the process. This paper presents a practical framework based on different dimension-reduction methods as well as calibration methods aimed at following over time chemical experiments organized in batches. To illustrate it, this paper uses pharmaceutical data collected in a research and development context towards industrial production. This methodological framework aims to reach two objectives. The first objective is to visualize and interpret in real time, or off-line, the kinetics of chemical reactions using the following dimension-reduction methods: principal component analysis (PCA), non-negative matrix factorization (NMF) and multivariate curve resolution (MCR). The results show that, due to their additional constraints, NMF and MCR allow a better interpretability of chemical reactions than PCA with a comparable quality of fit. Moreover, eventough NMF and MCR come from different fields, their algorithms share many similarities and produce close results. The second objective is to predict chemical component concentrations over time. For this second objective, the partial least squares regression (PLSR) is used in a one-step approach and compared with a two-step approach combining multivariate regression with PCA, NMF or MCR. The results show that spectra or scores obtained from unsupervised approaches PCA, NMF or MCR can be used to predict concentrations of the main chemical compounds continuously over all the time of the reaction with a good precision and with a gain of interpretability. For both objectives, possible model validation indices are also discussed including a leave-one-batch-out approach.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] SPPS of difficult sequences - A comparison of chemical conditions, synthetic strategies and on-line monitoring
    Dettin, M
    Pegoraro, S
    Rovero, P
    Bicciato, S
    Bagno, A
    DiBello, C
    JOURNAL OF PEPTIDE RESEARCH, 1997, 49 (01): : 103 - 111
  • [42] COMPARISON OF 2 STRATEGIES FOR ASSESSING ECOTOXICOLOGICAL ASPECTS OF COMPLEX WASTE-WATER FROM A CHEMICAL PHARMACEUTICAL PLANT
    BRORSON, T
    BJORKLUND, I
    SVENSTAM, G
    LANTZ, R
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1994, 13 (04) : 543 - 552
  • [43] In situ monitoring of the crystalline state of active pharmaceutical ingredients during high-shear wet granulation using a low-frequency Raman probe
    Nomura, Kazuya
    Titapiwatanakun, Varin
    Hisada, Hiroshi
    Koide, Tatsuo
    Fukami, Toshiro
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2020, 147 : 1 - 9
  • [44] Monitoring Chemical Reactions with SERS-Active Ag-Loaded Mesoporous TiO2 Films
    Mercedes Zalduendo, M.
    Oestreicher, Victor
    Langer, Judith
    Liz-Marzan, Luis M.
    Angelome, Paula C.
    ANALYTICAL CHEMISTRY, 2020, 92 (20) : 13656 - 13660
  • [45] Electrochemical oxidation coupled with liquid chromatography and mass spectrometry to study the oxidative stability of active pharmaceutical ingredients in solution: A comparison of off-line and on-line approaches
    Torres, Susana
    Brown, Roland
    Zelesky, Todd
    Scrivens, Garry
    Szucs, Roman
    Hawkins, Joel M.
    Taylor, Mark R.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2016, 131 : 71 - 79
  • [46] Multivariate curve resolution–alternating least squares (MCR-ALS) applied to spectroscopic data from monitoring chemical reactions processes
    M. Garrido
    F. X. Rius
    M. S. Larrechi
    Analytical and Bioanalytical Chemistry, 2008, 390 : 2059 - 2066
  • [47] Chemical-biological monitoring in drainage ditches in the orchading region 'Altes Land' part 1:: Application of pesticides and residues of active ingredients in surface water.
    Bischoff, G
    Stähler, M
    Ehlers, K
    Pestemer, W
    PESTICIDE IN AIR, PLANT, SOIL & WATER SYSTEM, 2003, : 831 - 840
  • [48] Multivariate curve resolution-alternating least squares (MCR-ALS) applied to spectroscopic data from monitoring chemical reactions processes
    Garrido, M.
    Rius, F. X.
    Larrechi, M. S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (08) : 2059 - 2066
  • [49] Integration of a plasma protein binding factor to the Chemical-Specific Adjustment Factor (CSAF) for facilitating the estimation of uncertainties in interspecies extrapolations when deriving health-based exposure limits for active pharmaceutical ingredients: Investigation of recent drug datasets
    Poulin, Patrick
    Arnett, Richard
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2017, 91 : 142 - 150
  • [50] ASSESSMENT OF NAIVE INHALER USER INHALATION PROFILES AND THE IMPACT ON SUBSEQUENT AEROSOL PERFORMANCE : COMPARISON OF A DRY POWDER INHALER (DPI) AND A PRESSURIZED METERED DOSE INHALER (PMDI) WITH VALVED HOLDING CHAMBER (VHC) USING THE SAME ACTIVE PHARMACEUTICAL INGREDIENTS (APIS)
    Suggett, Jason A.
    Nagel, Mark W.
    Mitchell, Jolyon P.
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2020, 33 (02) : A3 - A3