Comparison of chemometrics strategies for the spectroscopic monitoring of active pharmaceutical ingredients in chemical reactions

被引:5
|
作者
Thiel, Michel [1 ,4 ]
Sauwen, Nicolas [2 ]
Khamiakova, Tastiana [1 ]
Maes, Tor [3 ]
Govaerts, Bernadette [4 ]
机构
[1] Janssen Pharmaceut, Mfg & Appl Stat, Turnhoutseweg 30, B-2340 Beerse, Belgium
[2] Open Analyt NV, Jupiterstr 20, B-2600 Antwerp, Belgium
[3] Janssen Pharmaceut, API Small Mol Dev, Turnhoutseweg 30, B-2340 Beerse, Belgium
[4] UCLouvain, Inst Stat Biostat & Actuarial Sci ISBA, Louvain Inst Data Anal & Modeling Econ & Stat LID, Voie Roman Pays 20,Bte L1-04-01, B-1348 Louvain La Neuve, Belgium
关键词
Process monitoring; Spectroscopy; NMF; MCR; PCA; PLS; PAT;
D O I
10.1016/j.chemolab.2021.104273
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The Process Analytical Technology (PAT) initiative promoted by the Food and Drug Administration (FDA) encourages pharmaceutical companies to increase the use of new analytical technologies to perform constant monitoring of the critical quality attributes (CQA), allowing a better understanding and a better control of the process. This paper presents a practical framework based on different dimension-reduction methods as well as calibration methods aimed at following over time chemical experiments organized in batches. To illustrate it, this paper uses pharmaceutical data collected in a research and development context towards industrial production. This methodological framework aims to reach two objectives. The first objective is to visualize and interpret in real time, or off-line, the kinetics of chemical reactions using the following dimension-reduction methods: principal component analysis (PCA), non-negative matrix factorization (NMF) and multivariate curve resolution (MCR). The results show that, due to their additional constraints, NMF and MCR allow a better interpretability of chemical reactions than PCA with a comparable quality of fit. Moreover, eventough NMF and MCR come from different fields, their algorithms share many similarities and produce close results. The second objective is to predict chemical component concentrations over time. For this second objective, the partial least squares regression (PLSR) is used in a one-step approach and compared with a two-step approach combining multivariate regression with PCA, NMF or MCR. The results show that spectra or scores obtained from unsupervised approaches PCA, NMF or MCR can be used to predict concentrations of the main chemical compounds continuously over all the time of the reaction with a good precision and with a gain of interpretability. For both objectives, possible model validation indices are also discussed including a leave-one-batch-out approach.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Multicomponent Reactions for the Synthesis of Active Pharmaceutical Ingredients
    Cores, Angel
    Clerigue, Jose
    Orocio-Rodriguez, Emmanuel
    Carlos Menendez, J.
    PHARMACEUTICALS, 2022, 15 (08)
  • [2] Comparison of near-infrared spectroscopic methods for the identification of pharmaceutical excipients and active drug ingredients
    Palmer, K. E.
    Jee, R. D.
    Kraunsoe, J. A. E.
    Bellchambers, M.
    Moffat, A. C.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2005, 57 : S80 - S80
  • [3] Comparison of near-infrared spectroscopic methods for the identification of pharmaceutical excipients and active drug ingredients
    Palmer, K. E.
    Jee, R. D.
    Kraunsoe, J. A. E.
    Bellchambers, M.
    Moffat, A. C.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2005, 57 : S10 - S11
  • [4] Prioritization methodology for the monitoring of active pharmaceutical ingredients in hospital effluents
    Daouk, Silwan
    Chevre, Nathalie
    Vernaz, Nathalie
    Bonnabry, Pascal
    Dayer, Pierre
    Daali, Youssef
    Fleury-Souverain, Sandrine
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2015, 160 : 324 - 332
  • [5] Continuous flow reactions in the preparation of active pharmaceutical ingredients and fine chemicals
    Martins, Guilherme M.
    Braga, Felipe C.
    de Castro, Pedro P.
    Brocksom, Timothy J.
    de Oliveira, Kleber T.
    CHEMICAL COMMUNICATIONS, 2024, 60 (24) : 3226 - 3239
  • [6] One-Pot Reactions Accelerate the Synthesis of Active Pharmaceutical Ingredients
    Vaxelaire, Carine
    Winter, Philipp
    Christmann, Mathias
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2011, 50 (16) : 3605 - 3607
  • [7] Investigation of Polymorphism and Cocrystallization of Active Pharmaceutical Ingredients Using Vibrational Spectroscopic Techniques
    Du, Yong
    Xue, Jiadan
    CURRENT PHARMACEUTICAL DESIGN, 2016, 22 (32) : 4917 - 4928
  • [8] Classification of the ibuprofen active pharmaceutical ingredients by chemical patterns combining HPLC, 1H-NMR spectroscopy and chemometrics: traceability of legal medicines
    Raimondo, Mariangela
    Borioni, Anna
    Bartolomei, Monica
    Mosca, Antonina
    Gostoli, Gianluca
    ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2020, 56 (04): : 403 - 408
  • [9] Dielectric spectroscopic studies of three important active pharmaceutical ingredients - clofoctol, droperidol and probucol
    Sahra, M.
    Thayyil, M. Shahin
    Bansal, Arvind Kumar
    Ngai, K. L.
    Sulaiman, M. K.
    Shete, Ganesh
    Hussan, Safna K. P.
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2019, 505 : 28 - 36
  • [10] Consequences of New Approach of Chemical Stability Tests of Active Pharmaceutical Ingredients (APIs)
    Jamrogiewicz, Marzena
    FRONTIERS IN PHARMACOLOGY, 2016, 7