Development of a Searchable Database of Cryoablation Simulations for Use in Treatment Planning

被引:11
作者
Boas, F. Edward [1 ]
Srimathveeravalli, Govindarajan [1 ]
Durack, Jeremy C. [1 ]
Kaye, Elena A. [2 ]
Erinjeri, Joseph P. [1 ]
Ziv, Etay [1 ]
Maybody, Majid [1 ]
Yarmohammadi, Hooman [1 ]
Solomon, Stephen B. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 1275 York Ave, New York, NY 10065 USA
关键词
Cryoablation; Simulation; Prediction; Planning; PERCUTANEOUS CRYOABLATION; RADIOFREQUENCY ABLATION; GUIDED CRYOABLATION; LIVER-TUMORS; EXPERIENCE; EFFICACY; THERAPY; SAFETY; TRIAL;
D O I
10.1007/s00270-016-1562-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose To create and validate a planning tool for multiple-probe cryoablation, using simulations of ice ball size and shape for various ablation probe configurations, ablation times, and types of tissue ablated. Materials and Methods Ice ball size and shape was simulated using the Pennes bioheat equation. Five thousand six hundred and seventy different cryoablation procedures were simulated, using 1-6 cryoablation probes and 1-2 cm spacing between probes. The resulting ice ball was measured along three perpendicular axes and recorded in a database. Simulated ice ball sizes were compared to gel experiments (26 measurements) and clinical cryoablation cases (42 measurements). The clinical cryoablation measurements were obtained from a HIPAA-compliant retrospective review of kidney and liver cryoablation procedures between January 2015 and February 2016. Finally, we created a web-based cryoablation planning tool, which uses the cryoablation simulation database to look up the probe spacing and ablation time that produces the desired ice ball shape and dimensions. Results Average absolute error between the simulated and experimentally measured ice balls was 1 mm in gel experiments and 4 mm in clinical cryoablation cases. The simulations accurately predicted the degree of synergy in multiple-probe ablations. The cryoablation simulation database covers a wide range of ice ball sizes and shapes up to 9.8 cm. Conclusion Cryoablation simulations accurately predict the ice ball size in multiple-probe ablations. The cryoablation database can be used to plan ablation procedures: given the desired ice ball size and shape, it will find the number and type of probes, probe configuration and spacing, and ablation time required.
引用
收藏
页码:761 / 768
页数:8
相关论文
共 23 条
  • [1] [Anonymous], [No title captured], DOI DOI 10.1016/J.EURURO.2013.05.048
  • [2] Percutaneous image-guided cryoablation of painful metastases involving bone Multicenter Trial
    Callstrom, Matthew R.
    Dupuy, Damian E.
    Solomon, Stephen B.
    Beres, Robert A.
    Littrup, Peter J.
    Davis, Kirkland W.
    Paz-Fumagalli, Ricardo
    Hoffman, Cheryl
    Atwell, Thomas D.
    Charboneau, J. William
    Schmit, Grant D.
    Goetz, Matthew P.
    Rubin, Joseph
    Brown, Kathy J.
    Novotny, Paul J.
    Sloan, Jeff A.
    [J]. CANCER, 2013, 119 (05) : 1033 - 1041
  • [3] Chen M M, 1980, Ann N Y Acad Sci, V335, P137, DOI 10.1111/j.1749-6632.1980.tb50742.x
  • [4] Thermal ablation of tumours: biological mechanisms and advances in therapy
    Chu, Katrina F.
    Dupuy, Damian E.
    [J]. NATURE REVIEWS CANCER, 2014, 14 (03) : 199 - 208
  • [5] Evaluating Cryoablation of Metastatic Lung Tumors in Patients-Safety and Efficacy The ECLIPSE Trial-Interim Analysis at 1 Year
    de Baere, Thierry
    Tselikas, Lambros
    Woodrum, David
    Abtin, Fereidoun
    Littrup, Peter
    Deschamps, Frederic
    Suh, Robert
    Aoun, Hussein D.
    Callstrom, Matthew
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (10) : 1468 - 1474
  • [6] Cryoablation: Mechanism of Action and Devices
    Erinjeri, Joseph P.
    Clark, Timothy W. I.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (08) : S187 - S191
  • [7] Hammond C, 2000, Handb Chem Phys, P81
  • [8] Percutaneous Tumor Ablation Tools: Microwave, Radiofrequency, or Cryoablation-What Should You Use and Why?
    Hinshaw, J. Louis
    Lubner, Meghan G.
    Ziemlewicz, Timothy J.
    Lee, Fred T., Jr.
    Brace, Christopher L.
    [J]. RADIOGRAPHICS, 2014, 34 (05) : 1344 - 1362
  • [9] Finite-element analysis of ex vivo and in vivo hepatic cryoablation
    Kim, Cheolkyun
    O'Rourke, Ann P.
    Mahvi, David M.
    Webster, John G.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (07) : 1177 - 1185
  • [10] Kreith F., 2005, CRC HDB MECH ENG, VSecond