Comparison of the docetaxel concentration in human plasma measured with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and a nanoparticle immunoassay and clinical applications of that assay

被引:9
作者
Geng, Chunmei [1 ]
Li, Pingli [1 ]
Chen, Xuwang [1 ]
Yuan, Guiyan [1 ]
Guo, Nan [1 ]
Liu, Huanjun [1 ]
Zhang, Rui [1 ]
Guo, Ruichen [1 ]
机构
[1] Shandong Univ, Qilu Hosp, Inst Clin Pharmacol, Jinan 250012, Shandong, Peoples R China
关键词
LC-MS/MS; nanoparticle immunoassay; docetaxel; therapeutic drug monitoring; CELL LUNG-CANCER; VALIDATION; PACLITAXEL;
D O I
10.5582/bst.2017.01029
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
To determine the feasibility of using a nanoparticle immunoassay for clinical therapeutic drug monitoring (TDM) of docetaxel concentrations, a sensitive and simple method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established to measure the docetaxel concentration in human plasma and the results of LC-MS/MS and the immunoassay were compared. Docetaxel and paclitaxel (the internal standard, or IS) in human plasma were extracted through protein precipitation, separated on a Diamonsil C18 column (150 mm x 4.6 mm, 5 mu m), ionized with positive ions, and detected with LC-MS/MS in multi-reaction monitoring (MRM) mode. Plasma samples from 248 cancer patients were assayed with LC-MS/MS and a nanoparticle immunoassay. Data from the samples were analyzed with the statistical software SPSS and the software MedCalc. Results indicated that the calibration curve of the validated method of LC-MS/MS was linear over the range of 10-2,000 ng/mL, with an lowest limit of quantitation (LLOQ) of 10 ng/mL, and the intra-and inter-day precision and accuracy were both < +/- 15%. Comparison of the two methods indicated that results of the LC-MS/MS were closely related to those of the nanoparticle immunoassay, with a correlation coefficient (R) of 0.965 and acceptable 95% confidence intervals (CI) of. 231.7-331.1 ng/mL. Overall, the established method of LC-MC/MS and the nanoparticle immunoassay were both suitable for measurement of the docetaxel concentration in human plasma, and the immunoassay was far more cost-effective and better at clinical TDM of docetaxel in clinical practice.
引用
收藏
页码:202 / 208
页数:7
相关论文
共 22 条
[1]   Relationship between cytochrome 3A activity, inflammatory status and the risk of docetaxel-induced febrile neutropenia: a prospective study [J].
Alexandre, J. ;
Rey, E. ;
Girre, V. ;
Grabar, S. ;
Tran, A. ;
Montheil, V. ;
Rabillon, F. ;
Dieras, V. ;
Jullien, V. ;
Herait, P. ;
Pons, G. ;
Treluyer, J. -M. ;
Goldwasser, F. .
ANNALS OF ONCOLOGY, 2007, 18 (01) :168-172
[2]  
Alnaim Lamya, 2007, J Oncol Pharm Pract, V13, P207, DOI 10.1177/1078155207081133
[3]  
Andersen Anders, 2006, BMC Clin Pharmacol, V6, P2, DOI 10.1186/1472-6904-6-2
[4]   Clinical pharmalcokinetics of docetaxel - Recent developments [J].
Baker, SD ;
Sparreboom, A ;
Verweij, J .
CLINICAL PHARMACOKINETICS, 2006, 45 (03) :235-252
[5]   Therapeutic drug monitoring of imatinib in chronic myeloid leukemia: experience from 1216 patients at a centralized laboratory [J].
Bouchet, Stephane ;
Titier, Karine ;
Moore, Nicholas ;
Lassalle, Regis ;
Ambrosino, Basmah ;
Poulette, Sylvie ;
Schuld, Peter ;
Belanger, Coralie ;
Mahon, Francois-Xavier ;
Molimard, Mathieu .
FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2013, 27 (06) :690-697
[6]  
Bruno R, 2003, CLIN CANCER RES, V9, P1077
[7]   Population pharmacokinetics/pharmacodynamics of docetaxel in phase II studies in patients with cancer [J].
Bruno, R ;
Hille, D ;
Riva, A ;
Vivier, N ;
Huinnink, WWTB ;
van Oosterom, AT ;
Kaye, SB ;
Verweij, J ;
Fossella, FV ;
Valero, V ;
Rigas, JR ;
Seidman, AD ;
Chevallier, B ;
Fumoleau, P ;
Burris, HA ;
Ravclin, PM ;
Sheiner, LB .
JOURNAL OF CLINICAL ONCOLOGY, 1998, 16 (01) :187-196
[8]   An Automated Nanoparticle-Based Homogeneous Immunoassay for Determining Docetaxel Concentrations in Plasma [J].
Cline, Daniel J. ;
Zhang, Hongxia ;
Lundell, Gregory D. ;
Harney, Rebecca L. ;
Riaz, Hadia K. ;
Jarrah, Justin ;
Li, Yunying ;
Miyazaki, Makoto ;
Courtney, Jodi B. ;
Baburina, Irina ;
Salamone, Salvatore J. .
THERAPEUTIC DRUG MONITORING, 2013, 35 (06) :803-808
[9]   Development and validation of an ultrafiltration-UPLC-MS/MS method for rapid quantification of unbound docetaxel in human plasma [J].
Du, Ping ;
Han, Xiaohong ;
Li, Ning ;
Wang, Hongyu ;
Yang, Sheng ;
Song, Yuanyuan ;
Shi, Yuankai .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 967 :28-35
[10]   Therapeutic Drug Monitoring for the Individualization of Docetaxel Dosing: A Randomized Pharmacokinetic Study [J].
Engels, Frederike K. ;
Loos, Walter J. ;
van der Bol, Jessica M. ;
de Bruijn, Peter ;
Mathijssen, Ron H. J. ;
Verweij, Jaap ;
Mathot, Ron A. A. .
CLINICAL CANCER RESEARCH, 2011, 17 (02) :353-362