Thermal performance of horizontal closed-loop oscillating heat-pipe with check valves

被引:23
|
作者
Rittidech, S. [1 ]
Pipatpaiboon, N. [1 ]
Thongdaeng, S. [1 ]
机构
[1] Mahasarakham Univ, Fac Engn, Heat Pipe & Thermal Tools Design Res Lab, Kantarawichai Dist 44150, Mahasarakham, Thailand
关键词
Thermal performance; Closed-loop oscillating heat pipe; Check valve;
D O I
10.1007/s12206-009-1221-7
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This research investigated the thermal performance of various horizontal closed-loop oscillating heat-pipe systems with check valves (HCLOHPs/CVs). Numerous test systems were constructed using copper capillary tubes with assorted inner diameters, evaporator lengths, and check valves. The test systems were evaluated under normal operating conditions using ethanol, R123, and distilled water as working fluids. The system's evaporator sections were heated by hot water from a hot bath, and the heat was removed from the condenser sections by cold water from a cool bath. The adiabatic sections were well insulated with foam insulators. The heat-transfer performance of the various systems was evaluated in terms of the rate of heat transferred to the cold water at the condenser. The results showed that the heat-transfer performance of an HCLOHP/CV system could be improved by decreasing the evaporator length. The highest performance of all tested systems was obtained when the maximum number of system check valves was 2. The maximum heat flux occurred with a 2 mm inner diameter tube, and R123 was determined to be the most suitable working fluid.
引用
收藏
页码:545 / 550
页数:6
相关论文
共 50 条
  • [41] Closed-loop pulsating heat pipe
    Tong, BY
    Wong, TN
    Ooi, KT
    APPLIED THERMAL ENGINEERING, 2001, 21 (18) : 1845 - 1862
  • [42] Investigation on the performance of closed-loop pulsating heat pipe with surfactant
    Wang, Jiansheng
    Xie, Jinyuan
    Liu, Xueling
    APPLIED THERMAL ENGINEERING, 2019, 160
  • [43] Experimental investigation on thermal performance of phase change material coupled with closed-loop oscillating heat pipe (PCM/CLOHP) used in thermal management
    Zhao, Jiateng
    Rao, Zhonghao
    Liu, Chenzhen
    Li, Yimin
    APPLIED THERMAL ENGINEERING, 2016, 93 : 90 - 100
  • [44] Motion and Heat-Transfer Analysis of a Closed-Loop Oscillating Heat Pipe with a Magnetic Field
    Wongkasem, K.
    Rittidech, S.
    Bubphachot, B.
    JOURNAL OF ENHANCED HEAT TRANSFER, 2010, 17 (04) : 369 - 380
  • [45] CORRELATIONS TO PREDICT THERMAL PERFORMANCE AFFECTED BY WORKING FLUID'S PROPERTIES OF VERTICAL AND HORIZONTAL CLOSED-LOOP PULSATING HEAT PIPE
    Sakulchangsatjatai, Phrut
    Kammuang-Lue, Niti
    On-Ai, Kritsada
    Terdtoon, Pradit
    THERMAL SCIENCE, 2016, 20 (05): : 1555 - 1564
  • [46] Experimental study on the thermal performance of vertical closed-loop oscillating heat pipes and correlation modeling
    Qu, Jian
    Wang, Qian
    APPLIED ENERGY, 2013, 112 : 1154 - 1160
  • [47] Experimental investigation on the thermal performance of a closed oscillating heat pipe in thermal management
    Zhonghao Rao
    Qingchao Wang
    Jiateng Zhao
    Congliang Huang
    Heat and Mass Transfer, 2017, 53 : 3059 - 3071
  • [48] Experimental investigation on the thermal performance of a closed oscillating heat pipe in thermal management
    Rao, Zhonghao
    Wang, Qingchao
    Zhao, Jiateng
    Huang, Congliang
    HEAT AND MASS TRANSFER, 2017, 53 (10) : 3059 - 3071
  • [49] THERMAL PERFORMANCE OF HEAT-PIPE ARRAYS IN SOIL
    HEGAB, HE
    COLWELL, GT
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 1994, 26 (06) : 619 - 630
  • [50] Thermal characteristics of an ammonia-charged closed-loop pulsating heat pipe
    Md Shahidul Haque
    Antara Majumdar
    Md. Faisal Kader
    Md. Mahbubur Razzaq
    Journal of Mechanical Science and Technology, 2019, 33 : 1907 - 1914