Thermal performance of horizontal closed-loop oscillating heat-pipe with check valves

被引:23
|
作者
Rittidech, S. [1 ]
Pipatpaiboon, N. [1 ]
Thongdaeng, S. [1 ]
机构
[1] Mahasarakham Univ, Fac Engn, Heat Pipe & Thermal Tools Design Res Lab, Kantarawichai Dist 44150, Mahasarakham, Thailand
关键词
Thermal performance; Closed-loop oscillating heat pipe; Check valve;
D O I
10.1007/s12206-009-1221-7
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This research investigated the thermal performance of various horizontal closed-loop oscillating heat-pipe systems with check valves (HCLOHPs/CVs). Numerous test systems were constructed using copper capillary tubes with assorted inner diameters, evaporator lengths, and check valves. The test systems were evaluated under normal operating conditions using ethanol, R123, and distilled water as working fluids. The system's evaporator sections were heated by hot water from a hot bath, and the heat was removed from the condenser sections by cold water from a cool bath. The adiabatic sections were well insulated with foam insulators. The heat-transfer performance of the various systems was evaluated in terms of the rate of heat transferred to the cold water at the condenser. The results showed that the heat-transfer performance of an HCLOHP/CV system could be improved by decreasing the evaporator length. The highest performance of all tested systems was obtained when the maximum number of system check valves was 2. The maximum heat flux occurred with a 2 mm inner diameter tube, and R123 was determined to be the most suitable working fluid.
引用
收藏
页码:545 / 550
页数:6
相关论文
共 50 条
  • [31] Heat-transfer characteristics of the top heat mode closed-loop oscillating heat pipe with a check valve (THMCLOHP/CV)
    N. Bhuwakietkumjohn
    S. Rittidech
    A. Pattiya
    Journal of Applied Mechanics and Technical Physics, 2012, 53 : 224 - 230
  • [32] The top heat mode of closed loop oscillating heat pipe with check valves at the top heat mode (THMCLOHP/CV): A thermodynamic study
    Bhuwakietkumjohn N.
    Parametthanuwat T.
    International Journal of Mechanical and Materials Engineering, 2014, 9 (1)
  • [33] Experimental investigation of the thermal performance of closed loop flat plate oscillating heat pipe
    Mehta, Kamlesh
    Mehta, Nirvesh
    Patel, Vivek
    EXPERIMENTAL HEAT TRANSFER, 2021, 34 (01) : 85 - 103
  • [34] DEVELOPMENT OF A CLOSED-LOOP HEAT-PIPE FOR HEAT RECOVERY WITH MINI-CHANNELS ENHANCING EVAPORATION
    Rocha, Bruno Duarte
    Mazzoco, Rene Reyes
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, PTS A AND B, 2008, : 661 - 667
  • [35] Two-phase flow patterns of a top heat mode closed loop oscillating heat pipe with check valves (THMCLOHP/CV)
    S. Thongdaeng
    B. Bubphachot
    S. Rittidech
    Journal of Applied Mechanics and Technical Physics, 2016, 57 : 1101 - 1107
  • [36] Two-phase flow patterns of a top heat mode closed loop oscillating heat pipe with check valves (THMCLOHP/CV)
    Thongdaeng, S.
    Bubphachot, B.
    Rittidech, S.
    JOURNAL OF APPLIED MECHANICS AND TECHNICAL PHYSICS, 2016, 57 (06) : 1101 - 1107
  • [37] Heat transfer characteristics of a novel closed-loop pulsating heat pipe with a check valve
    Feng, Chen
    Wan, Zhenping
    Mo, Haijun
    Tang, Heng
    Lu, Longsheng
    Tang, Yong
    APPLIED THERMAL ENGINEERING, 2018, 141 : 558 - 564
  • [38] SOLAR CHEMICAL HEAT-PIPE IN CLOSED-LOOP OPERATION - MATHEMATICAL-MODEL AND EXPERIMENTS
    SEGAL, A
    LEVY, M
    SOLAR ENERGY, 1993, 51 (05) : 367 - 376
  • [39] Influence of the channel profile on the thermal resistance of closed-loop flat-plate oscillating heat pipe
    Mehta, Kamlesh
    Mehta, Nirvesh
    Patel, Vivek
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (03)
  • [40] Influence of the channel profile on the thermal resistance of closed-loop flat-plate oscillating heat pipe
    Kamlesh Mehta
    Nirvesh Mehta
    Vivek Patel
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42