Detection of negative sequence components in diagnosing and tolerating open-gate fault for a voltage-source inverter in an induction motor drive

被引:3
|
作者
Al-Gahtani, Saad F. [1 ]
Azazi, Haitham Z. [1 ,2 ]
Nelms, Robert M. [3 ]
Elbarbary, Zakaria M. [1 ,4 ]
机构
[1] King Khalid Univ, Coll Engn, Elect Engn Dept, Abha, Saudi Arabia
[2] Menoufia Univ, Fac Engn, Elect Engn Dept, Shibin Al Kawm, Egypt
[3] Auburn Univ, Elect & Comp Engn Dept, Auburn, AL 36849 USA
[4] Kafrelsheikh Univ, Dept Elect Engn, Fac Engn, Kafr Al Sheikh, Egypt
关键词
induction motor drives; invertors; fault diagnosis; voltage-source convertors; failure analysis; transistors; electric current measurement; machine control; power converter faults; electrical system faults; short-gate faults; fault diagnostic; tolerant control system; three-phase voltage-source inverter; negative sequence components; motor currents; tolerating open-gate fault; induction motor drive; transistor failures; diagnostic technique; detection method; logic functions; inverter topology; faulty inverter; steady-state conditions; transient conditions; OPEN-CIRCUIT FAULTS; MACHINE; SYSTEM;
D O I
10.1049/iet-pel.2020.0289
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power converter faults represent about 12% of electrical system faults. More than 31% of these converter faults are caused by the transistors in the converters. These transistor failures are classified into open-gate and short-gate faults. A fault diagnostic and tolerant control system is proposed in this study for an open-gate fault of a three-phase voltage-source inverter (VSI). The system under study is an induction motor fed by a VSI. The diagnostic technique uses a detection method of positive and negative sequence components, which requires only the measurement of motor currents. The diagnostic signals are derived from the negative sequence components of the motor currents. These signals are then compared using logic functions to trigger the tolerant control. In the case of an open-gate fault, the tolerant system converts the inverter topology from six switches to four switches where the faulty inverter leg is disconnected. The proposed control method was evaluated under steady-state and transient conditions through simulation and experiments. The results confirm an effective and reliable performance of the motor under an open-gate fault.
引用
收藏
页码:4194 / 4203
页数:10
相关论文
共 43 条
  • [21] High-Performance Fault Diagnosis in PWM Voltage-Source Inverters for Vector-Controlled Induction Motor Drives
    Zhang, Jianghan
    Zhao, Jin
    Zhou, Dehong
    Huang, Chengguang
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (11) : 6087 - 6099
  • [22] Fault diagnosis and fault-tolerant finite control set-model predictive control of a multiphase voltage-source inverter supplying BLDC motor
    Salehifar, Mehdi
    Moreno-Equilaz, Manuel
    ISA TRANSACTIONS, 2016, 60 : 143 - 155
  • [23] A Direct Torque Control Scheme for Dual Inverter fed Induction Motor Drive with a Common DC Voltage Source
    Nirsha, K., I
    Rajeevan, P. P.
    IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 1674 - 1679
  • [24] A dual two-level inverter with a single source for open end winding induction motor drive application
    Chowdhury, Shajjad
    Wheeler, Patrick
    Gerada, Chris
    Patel, Chintan
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [25] Multifunctional Grid-Connected Voltage Source Inverter to Drive Induction Motor Operating With High-Inertia Load
    Madanzadeh, Sadjad
    Bukhari, Syed Sabir Hussain
    Ro, Jong-Suk
    IEEE ACCESS, 2020, 8 : 196765 - 196774
  • [26] Modified H-bridge inverter based fault-tolerant multilevel topology for open-end winding induction motor drive
    Reddy, Kedika Narender
    Pradabane, Srinivasan
    IET POWER ELECTRONICS, 2019, 12 (11) : 2810 - 2820
  • [27] Modulated Model Predictive Control of Assymetric Source Dual Inverter System for Open End Winding Induction Motor Drive
    Chowdhury, Shajjad
    Wheeler, Patrick
    Gerada, Chris
    Rivera, Marco
    2017 IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (SPEC), 2017, : 155 - 161
  • [28] Load-Commutated SCR-Based Current Source Inverter Fed Induction Motor Drive With Open-End Stator Windings
    Sebastian, Richu C.
    Rajeevan, P. P.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (03) : 2031 - 2038
  • [29] Design and Implementation of Trans-Z-Source Inverter-Fed Induction Motor Drive with Fault-Tolerant Capability
    Sharma, Vivek
    Hossain, M. J.
    Ali, S. M. N.
    Kashif, Muhammad
    Fernandez, Edstan
    2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 690 - 695
  • [30] A Nine-Level Inverter Topology for Medium-Voltage Induction Motor Drive With Open-End Stator Winding
    Rajeevan, P. P.
    Sivakumar, K.
    Gopakumar, K.
    Patel, Chintan
    Abu-Rub, Haitham
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (09) : 3627 - 3636