Detection of negative sequence components in diagnosing and tolerating open-gate fault for a voltage-source inverter in an induction motor drive

被引:3
|
作者
Al-Gahtani, Saad F. [1 ]
Azazi, Haitham Z. [1 ,2 ]
Nelms, Robert M. [3 ]
Elbarbary, Zakaria M. [1 ,4 ]
机构
[1] King Khalid Univ, Coll Engn, Elect Engn Dept, Abha, Saudi Arabia
[2] Menoufia Univ, Fac Engn, Elect Engn Dept, Shibin Al Kawm, Egypt
[3] Auburn Univ, Elect & Comp Engn Dept, Auburn, AL 36849 USA
[4] Kafrelsheikh Univ, Dept Elect Engn, Fac Engn, Kafr Al Sheikh, Egypt
关键词
induction motor drives; invertors; fault diagnosis; voltage-source convertors; failure analysis; transistors; electric current measurement; machine control; power converter faults; electrical system faults; short-gate faults; fault diagnostic; tolerant control system; three-phase voltage-source inverter; negative sequence components; motor currents; tolerating open-gate fault; induction motor drive; transistor failures; diagnostic technique; detection method; logic functions; inverter topology; faulty inverter; steady-state conditions; transient conditions; OPEN-CIRCUIT FAULTS; MACHINE; SYSTEM;
D O I
10.1049/iet-pel.2020.0289
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Power converter faults represent about 12% of electrical system faults. More than 31% of these converter faults are caused by the transistors in the converters. These transistor failures are classified into open-gate and short-gate faults. A fault diagnostic and tolerant control system is proposed in this study for an open-gate fault of a three-phase voltage-source inverter (VSI). The system under study is an induction motor fed by a VSI. The diagnostic technique uses a detection method of positive and negative sequence components, which requires only the measurement of motor currents. The diagnostic signals are derived from the negative sequence components of the motor currents. These signals are then compared using logic functions to trigger the tolerant control. In the case of an open-gate fault, the tolerant system converts the inverter topology from six switches to four switches where the faulty inverter leg is disconnected. The proposed control method was evaluated under steady-state and transient conditions through simulation and experiments. The results confirm an effective and reliable performance of the motor under an open-gate fault.
引用
收藏
页码:4194 / 4203
页数:10
相关论文
共 43 条
  • [1] Open gate fault diagnosis and tolerant for voltage source inverter fed speed sensorless induction motor drive
    Salem, Elbarbary Z. M.
    Azazi, Haitham Z.
    Al-Gahtani, Saad F.
    Elkholy, Mahmoud M.
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2020, 107 (11) : 1754 - 1772
  • [2] Novel Fuzzy-Based Open-Switch Fault Detection Scheme of Voltage Source Inverter Induction Motor Drive
    Gardouh, Ahmed S.
    Abulanwar, Sayed
    Deng, Fujin
    Gouda, Eid
    Ghanem, Abdelhady
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (11) : 14961 - 14973
  • [3] Neural Classification Method in Fault Detection and Diagnosis for Voltage Source Inverter in Variable Speed Drive with Induction Motor
    Kadri, Farid
    Drid, Said
    Djeffal, Faycal
    Chrifi-Alaoui, Larbi
    2013 8TH INTERNATIONAL CONFERENCE AND EXHIBITION ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2013,
  • [4] Neural Direct Torque Control for Induction Motor under Voltage Source Inverter Open Switch Fault
    Kadri, Farid
    Hamida, Mohamed A.
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2020, 13 (04) : 571 - 579
  • [5] Transistor Open-Circuit Fault Disgnosis of Three Phase Voltage-Source Inverter Fed Induction Motor Based on Information Fusion
    Wang, Meng
    Zhao, Jin
    Wu, ZhaFeng
    Yang, Huangwen
    PROCEEDINGS OF THE 2017 12TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2017, : 1591 - 1594
  • [6] Open-circuit fault diagnosis of a voltage-source inverter in a UPS system
    Li J.
    Shi R.
    Wang Y.
    Li S.
    Yang P.
    Bao H.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (23): : 148 - 153
  • [7] Output Voltage Correction for a Voltage Source Type Inverter of an Induction Motor Drive
    Hoshino, Tetsuma
    Itoh, Jun-ichi
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (09) : 2440 - 2449
  • [8] Gram Matrix Based Transistor Open-Circuit Fault Diagnosis Method for Voltage-Source Inverter Fed Vector Controlled Induction Motor Drives
    Zhou, Yang
    Wu, Feng
    Zhao, Jin
    2020 IEEE 9TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC2020-ECCE ASIA), 2020, : 245 - 251
  • [9] Fault Diagnosis of Voltage Source Inverter for Induction Motor Drives Using Decision Tree
    Nguyen, Ngoc-Tu
    Nguyen, Huu-Phuc
    9TH INTERNATIONAL CONFERENCE ON ROBOTIC, VISION, SIGNAL PROCESSING AND POWER APPLICATIONS: EMPOWERING RESEARCH AND INNOVATION, 2017, 398 : 819 - 826
  • [10] Simple threshold method in fault diagnosis for voltage source inverter in a direct torque control induction motor drive
    Kadri F.
    Hamida M.A.
    Recent Patents on Engineering, 2020, 14 (04) : 598 - 609