Correlation between BOLD-fMRI and EEG signal changes in response to visual stimulus frequency in humans

被引:84
作者
Singh, M
Kim, S
Kim, TS
机构
[1] Univ So Calif, Dept Radiol, Los Angeles, CA 90089 USA
[2] Univ So Calif, Dept Biomed Engn, Los Angeles, CA 90089 USA
关键词
BOLD; fMRI; electroencephalography; visual stimulation;
D O I
10.1002/mrm.10335
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The correlation between signals acquired using electroencephalography (EEG) and fMRI was investigated in humans during visual stimulation. Evoked potential EEG and BOLD fMRI data were acquired independently under similar conditions from eight subjects during stimulation by a checkerboard flashed at frequencies ranging from 2-12 Hz. The results indicate highly correlated changes in the strength of the EEG signal averaged over two occipital electrodes and the BOLD signal within the occipital lobe as a function of flash frequency for 7/8 subjects (average linear correlation coefficient of 0.76). Both signals peaked at approximately 8 Hz. For one subject the correlation coefficient was 0.20; the EEG signal peaked at 6 Hz and the BOLD signal peaked at 10 Hz. Overall, the EEG and BOLD signals, each averaged over 40-sec stimulation periods, appear to be coupled linearly during visual stimulation by a flashing checkerboard.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 30 条
[1]   Coupling of neural activation to blood flow in the somatosensory cortex of rats is time-intensity separable, but not linear [J].
Ances, BM ;
Zarahn, E ;
Greenberg, JH ;
Detre, JA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2000, 20 (06) :921-930
[2]   Linear coupling between functional magnetic resonance imaging and evoked potential amplitude in human somatosensory cortex [J].
Arthurs, OJ ;
Williams, EJ ;
Carpenter, TA ;
Pickard, JD ;
Boniface, SJ .
NEUROSCIENCE, 2000, 101 (04) :803-806
[3]   PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN [J].
BANDETTINI, PA ;
JESMANOWICZ, A ;
WONG, EC ;
HYDE, JS .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :161-173
[4]  
BELLIVEAU JW, 1992, INVEST RADIOL, V27, P59
[5]  
Brinker G, 1999, MAGNET RESON MED, V41, P469, DOI 10.1002/(SICI)1522-2594(199903)41:3<469::AID-MRM7>3.0.CO
[6]  
2-9
[7]   MEG VERSUS EEG LOCALIZATION TEST USING IMPLANTED SOURCES IN THE HUMAN BRAIN [J].
COHEN, D ;
CUFFIN, BN ;
YUNOKUCHI, K ;
MANIEWSKI, R ;
PURCELL, C ;
COSGROVE, GR ;
IVES, J ;
KENNEDY, JG ;
SCHOMER, DL .
ANNALS OF NEUROLOGY, 1990, 28 (06) :811-817
[8]   Dynamic statistical parametric mapping: Combining fMRI and MEG for high-resolution imaging of cortical activity [J].
Dale, AM ;
Liu, AK ;
Fischl, BR ;
Buckner, RL ;
Belliveau, JW ;
Lewine, JD ;
Halgren, E .
NEURON, 2000, 26 (01) :55-67
[9]   Functional MRI at 1.5 tesla: A comparison of the blood oxygenation level-dependent signal and electrophysiology [J].
Disbrow, EA ;
Slutsky, DA ;
Roberts, TPL ;
Krubitzer, LA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (17) :9718-9723
[10]   NEURONAL GENERATORS OF THE VISUAL EVOKED-POTENTIALS - INTRACEREBRAL RECORDING IN AWAKE HUMANS [J].
DUCATI, A ;
FAVA, E ;
MOTTI, EDF .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 71 (02) :89-99