Impact of Contact Constraints on the Dynamics of Idealized Intracranial Saccular Aneurysms

被引:4
作者
Alam, Manjurul [1 ]
Seshaiyer, Padmanabhan [2 ]
机构
[1] George Mason Univ, Dept Bioengn, Fairfax, VA 22030 USA
[2] George Mason Univ, Dept Math Sci, Fairfax, VA 22030 USA
来源
BIOENGINEERING-BASEL | 2019年 / 6卷 / 03期
关键词
intracranial aneurysms; rupture potential; nerve tissues; contact constraints; finite element analysis;
D O I
10.3390/bioengineering6030077
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The rupture potential of intracranial aneurysms is an important medical question for physicians. While most intracranial (brain) aneurysms are asymptomatic, the quantification of rupture potential of both symptomatic and asymptomatic lesions is an active area of research. Furthermore, an intracranial aneurysm constrained by an optic nerve tissue might be a scenario for a physician to deal with during the treatment process. In this work, we developed a computational model of an idealized intracranial saccular aneurysm constrained by a rigid nerve tissue to investigate the impact of constrained nerve tissues on the dynamics of aneurysms. A comparative parametric study for constraints of varying length on aneurysm surface was considered. Our computational results demonstrated the impact of contact constraints on the level of stress near the fundus and provided insight on when these constraints can be protective and when they can be destructive. The results show that lesions with long contact constraints generated higher stress (0.116 MPa), whereas lesions without constraints generated less stress (0.1 MPa) at the fundus, which indicated that lesions with nerve constraints can be protective and less likely to rupture than the lesions without constraints. Moreover, lesions with point load on the fundus generated the highest stress (18.15 MPa) and, hence, they can be destructive.
引用
收藏
页数:11
相关论文
共 30 条
[1]  
Alam M., 2018, P APS MARCH M
[2]  
ALBERICO RA, 1995, AM J NEURORADIOL, V16, P1571
[3]   Distributed Computational Method for Coupled Fluid Structure Thermal Interaction Applications [J].
Aulisa, E. ;
Manservisi, S. ;
Seshaiyer, P. ;
Idesman, A. .
JOURNAL OF ALGORITHMS & COMPUTATIONAL TECHNOLOGY, 2010, 4 (03) :291-309
[4]   Mechanical identification of layer-specific properties of mouse carotid arteries using 3D-DIC and a hyperelastic anisotropic constitutive model [J].
Badel, Pierre ;
Avril, Stephane ;
Lessner, Susan ;
Sutton, Michael .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2012, 15 (01) :37-48
[5]   The risk of rupture in untreated aneurysms: The impact of size, gender, and expansion rate [J].
Brown, PM ;
Zelt, DT ;
Sobolev, B .
JOURNAL OF VASCULAR SURGERY, 2003, 37 (02) :280-283
[6]   Hemodynamics and Rupture of Terminal Cerebral Aneurysms [J].
Castro, Marcelo ;
Putman, Christopher ;
Radaelli, Alessandro ;
Frangi, Alejandro ;
Cebral, Juan .
ACADEMIC RADIOLOGY, 2009, 16 (10) :1201-1207
[7]   Association of Hemodynamic Characteristics and Cerebral Aneurysm Rupture [J].
Cebral, J. R. ;
Mut, F. ;
Weir, J. ;
Putman, C. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (02) :264-270
[8]  
Cebral JR, 2005, AM J NEURORADIOL, V26, P2550
[9]   Review of Cerebral Aneurysm Formation, Growth, and Rupture [J].
Chalouhi, Nohra ;
Hoh, Brian L. ;
Hasan, David .
STROKE, 2013, 44 (12) :3613-3622
[10]   FREE AND CONSTRAINED INFLATION OF ELASTIC MEMBRANES IN RELATION TO THERMOFORMING - NON-AXISYMMETRIC PROBLEMS [J].
CHARRIER, JM ;
SHRIVASTAVA, S ;
WU, R .
JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 1989, 24 (02) :55-74