MATLAB Interface for Portable Micro-electrode Impedance Measurements

被引:0
|
作者
Larsen, Eric P. [1 ]
Perez-Castillejos, Raquel [1 ]
机构
[1] Univ Hts, New Jersey Inst Technol, Tissue Models Lab, Newark, NJ 07102 USA
来源
2015 41ST ANNUAL NORTHEAST BIOMEDICAL ENGINEERING CONFERENCE (NEBEC) | 2015年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Advances in microfabrication have generated new interest in electrical impedance biosensors. These sensors allow observations to be made remotely and continuously in a form that is easily processed by a computer. However determining the key frequency/impedance relationship of such a sensor requires specialized and costly hardware. Here we present MATLAB scripts able to determine the frequency/impedance characteristic of an impedimetric sensor just using a laptop. Salt concentration was quantified via this MATLAB-based approach.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Electric field calibration in micro-electrode chambers by temperature measurements
    Glasser, H
    Schnelle, T
    Müller, T
    Fuhr, G
    THERMOCHIMICA ACTA, 1999, 333 (02) : 183 - 190
  • [2] Stretchable micro-electrode array
    Maghribi, M
    Hamilton, J
    Polla, D
    Rose, K
    Wilson, T
    Krulevitch, P
    2ND ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2002, : 80 - 83
  • [3] MICRO-ELECTRODE MEASUREMENTS OF TRANSMEMBRANE POTENTIAL OF CHLOROPLASTS AND ITS PHOTOINDUCED CHANGES
    BULYCHEV, AA
    ANDRIANOV, VK
    LITVIN, FF
    KURELLA, GA
    NATURE, 1972, 236 (5343) : 175 - +
  • [4] A micro-electrode and unicellular stimulation
    Hyde, IH
    BIOLOGICAL BULLETIN, 1921, 40 (03): : 130 - 133
  • [5] Impedance studies of bio-behavior and chemosensitivity of cancer cells by micro-electrode arrays
    Liu, Qingjun
    Yu, JinJiang
    Xiao, Lidan
    On Tang, Johnny Cheuk
    Zhang, Yu
    Wang, Ping
    Yang, Mo
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1305 - 1310
  • [6] A micro-electrode array biosensor for impedance spectroscopy of human umbilical vein endothelial cells
    Rahman, Abdur Rub Abdur
    Lo, Chun-Min
    Bhansali, Shekhar
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 118 (1-2) : 115 - 120
  • [7] IMPROVED SIMPLE TUNGSTEN MICRO-ELECTRODE
    VIDYASAGAR, TR
    PERRY, GW
    BRAIN RESEARCH BULLETIN, 1979, 4 (02) : 285 - 286
  • [8] MICRO-ELECTRODE STIMULATION OF FROG SKIN
    CATTON, WT
    JOURNAL OF PHYSIOLOGY-LONDON, 1957, 136 (01): : P33 - P34
  • [9] A POSITIVE PRESSURE MANIPULATOR FOR A MICRO-ELECTRODE
    GILLS, JP
    NASHOLD, BS
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1960, 12 (01): : 212 - 213
  • [10] Carbon nanotube micro-electrode array
    Gabay, T.
    Ben-David, M.
    Kalifa, I.
    Abrams, Z. R.
    Sorkin, R.
    Ben-Jacob, E.
    Hanein, Y.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,