Measurement of uni-planar and sport specific trunk motion using magneto-inertial measurement units: The concurrent validity of Noraxon and Xsens systems relative to a retro-reflective system

被引:18
作者
Cottam, Daniel S. [1 ,2 ,7 ]
Campbell, Amity C. [3 ,8 ]
Davey, Paul C. [3 ,8 ]
Kent, Peter [3 ,4 ,8 ]
Elliott, Bruce C. [1 ,9 ]
Alderson, Jacqueline A. [1 ,5 ,6 ,9 ]
机构
[1] Univ Western Australia, Sch Human Sci Exercise & Sport Sci, Perth, WA, Australia
[2] Australian Inst Sport, Canberra, ACT, Australia
[3] Curtin Univ, Sch Physiotherapy & Exercise Sci, Perth, WA, Australia
[4] Univ Southern Denmark, Dept Sports Sci & Clin Biomech, Odense, Denmark
[5] Univ Western Australia, Minderoo Tech & Policy Lab, UWA Law Sch, Perth, WA, Australia
[6] Auckland Univ Technol, Sports Performance Res Inst New Zealand SPRINZ, Fac Hlth & Environm Sci, Auckland, New Zealand
[7] Australian Inst Sport, Leverrier St, Bruce, ACT 2602, Australia
[8] Curtin Univ, Kent St, Bentley, WA 6102, Australia
[9] Univ Western Australia, 35 Stirling Hwy, Crawley, WA 6009, Australia
关键词
Inertial measurement unit; Trunk; Bowling; FAST BOWLERS; ORIENTATION; SENSORS; KINEMATICS;
D O I
10.1016/j.gaitpost.2021.11.012
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: There is a range of magneto-inertial measurement unit (MIMU) systems commercially available, however sensor specifications and fusion methods vary considerably between manufacturers. Such variability can influence the concurrent validity of MIMUs relative to reference standard measurement devices. Different MIMUs have been compared during static or low-velocity conditions, with higher-velocity movements assessed in robotic-based studies. However, there is a need for the concurrent validity of higher-velocity movements to be established in human-based studies. Research question: This study aimed to assess the concurrent validity of two commercial MIMU systems (Noraxon and Xsens), relative to a 'gold-standard' retro-reflective motion capture system, when measuring trunk angles during uni-planar range of motion (ROM) and cricket bowling, which involves high-speed, multi-planar movements. Methods: For this criterion-based validity study, both MIMU systems incorporated comparable sensor specificaotions and employed Kalman filter sensor fusion algorithms. The MIMU based angles were compared with angles derived from concurrently captured three-dimensional retro-reflective data for 10 fast-medium bowlers. Statisotical parametric mapping and root mean squared differences (RMSD) were computed for both MIMU systems. Results: One-dimensional statistical parametric mapping showed no significant differences for angles from both MIMU systems when compared with retro-reflective based angle outputs. The MIMU systems produced ROM RMSDs between 1.4 +/- 1.0. and 2.6 +/- 1.5.. One system displayed RMSDs between 4.6 +/- 1.4. and 7.4 +/- 1.9. during bowling, indicating functionally relevant differences to retro-reflective derived angles. There were some small but statistically significant differences in RMSDs between the MIMU systems. Significance: MIMU-based angle accuracy is poorer during high-speed, multi-planar movement than uni-planar tasks. Comparable MIMU systems can produce varying measurements during ROM and bowling tasks. It is likely that varying sample rates and sensor fusion algorithm parameters contributed to the differences.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 28 条
[1]   The biomechanics of fast bowling in men's cricket: A review [J].
Bartlett, RM ;
Stockill, NP ;
Elliott, BC ;
Burnett, AF .
JOURNAL OF SPORTS SCIENCES, 1996, 14 (05) :403-424
[2]   Lumbar load in adolescent fast bowlers: A prospective injury study [J].
Bayne, Helen ;
Elliott, Bruce ;
Campbell, Amity ;
Alderson, Jacqueline .
JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2016, 19 (02) :117-122
[3]   Estimating Orientation Using Magnetic and Inertial Sensors and Different Sensor Fusion Approaches: Accuracy Assessment in Manual and Locomotion Tasks [J].
Bergamini, Elena ;
Ligorio, Gabriele ;
Summa, Aurora ;
Vannozzi, Giuseppe ;
Cappozzo, Aurelio ;
Sabatini, Angelo Maria .
SENSORS, 2014, 14 (10) :18625-18649
[4]   Trunk Inclination Estimate During the Sprint Start Using an Inertial Measurement Unit: A Validation Study [J].
Bergamini, Elena ;
Guillon, Pelagie ;
Camomilla, Valentina ;
Pillet, Helene ;
Skalli, Wafa ;
Cappozzo, Aurelio .
JOURNAL OF APPLIED BIOMECHANICS, 2013, 29 (05) :622-627
[5]   Comparing inertial measurement units and marker-based biomechanical models during dynamic rotation of the torso [J].
Brice, Sara M. ;
Phillips, Elissa J. ;
Millett, Emma L. ;
Hunter, Adam ;
Philippa, Bronson .
EUROPEAN JOURNAL OF SPORT SCIENCE, 2020, 20 (06) :767-775
[6]   Use of inertial measurement units for measuring torso and pelvis orientation, and shoulder-pelvis separation angle in the discus throw [J].
Brice, Sara M. ;
Hurley, Matthew ;
Phillips, Elissa J. .
INTERNATIONAL JOURNAL OF SPORTS SCIENCE & COACHING, 2018, 13 (06) :985-992
[7]   Three-dimensional measurement of lumbar spine kinematics for fast bowlers in cricket [J].
Burnett, AF ;
Barrett, CJ ;
Marshall, RN ;
Elliott, BC ;
Day, RE .
CLINICAL BIOMECHANICS, 1998, 13 (08) :574-583
[8]   Functional calibration does not improve the concurrent validity of magneto-inertial wearable sensor-based thorax and lumbar angle measurements when compared with retro-reflective motion capture [J].
Cottam, Daniel S. ;
Campbell, Amity C. ;
Davey, Paul C. ;
Kent, Peter ;
Elliott, Bruce C. ;
Alderson, Jacqueline A. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (11-12) :2253-2262
[9]   G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences [J].
Faul, Franz ;
Erdfelder, Edgar ;
Lang, Albert-Georg ;
Buchner, Axel .
BEHAVIOR RESEARCH METHODS, 2007, 39 (02) :175-191
[10]   Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion [J].
Filippeschi, Alessandro ;
Schmitz, Norbert ;
Miezal, Markus ;
Bleser, Gabriele ;
Ruffaldi, Emanuele ;
Stricker, Didier .
SENSORS, 2017, 17 (06)