Filtration through nylon membranes negatively affects analysis of arsenic and phosphate by the molybdenum blue method

被引:17
作者
Heimann, A. C. [1 ]
Jakobsen, R. [1 ]
机构
[1] Tech Univ Denmark, Inst Environm & Resources, DK-2800 Lyngby, Denmark
关键词
molybdenum blue; nylon membranes; arsenic; phosphate; groundwater; syringe filters;
D O I
10.1016/j.talanta.2006.11.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Filtering synthetic arsenic- or phosphate-containing solutions (1.5-47.6 mu mol/L) with nylon syringe filters significantly reduced absorbances (by 6-74%) when analyzed with the colorimetric molybdenum blue method. Filtering the same solutions with cellulose acetate syringe filters yielded no significant differences as compared to unfiltered controls. The detrimental effect of nylon membranes was also observed when pure Milli-Q water was filtered and Subsequently spiked with arsenic(III) or phosphate suggesting that some compound(s) eluting from the filter membranes interfere with the color formation in the assay. Consequently, we caution against using nylon filters when filtering water samples for the determination of arsenic or phosphate with the molybdenum blue method. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:839 / 841
页数:3
相关论文
共 20 条
[1]   MICROBE GROWS BY REDUCING ARSENIC [J].
AHMANN, D ;
ROBERTS, AL ;
KRUMHOLZ, LR ;
MOREL, FMM .
NATURE, 1994, 371 (6500) :750-750
[2]   Isolation and characterization of arsenate-reducing bacteria from arsenic-contaminated sites in New Zealand [J].
Anderson, CR ;
Cook, GM .
CURRENT MICROBIOLOGY, 2004, 48 (05) :341-347
[3]  
Appelo C. A. J, 2005, GEOCHEMISTRY GROUNDW, P649
[4]  
Carvalho L. H. M., 1998, ECOTOXICOL ENV RESTO, V1, P13
[5]   A rapid colorimetric method for measuring arsenic concentrations in groundwater [J].
Dhar, RK ;
Zheng, Y ;
Rubenstone, J ;
van Geen, A .
ANALYTICA CHIMICA ACTA, 2004, 526 (02) :203-209
[6]  
Eaton A.D., 1995, STANDARD METHODS EXA, P1325
[7]   In situ determination of silicic acid in sea water based on FIA and colorimetric dual-wavelength measurements. [J].
Floch, J ;
Blain, S ;
Birot, D ;
Treguer, P .
ANALYTICA CHIMICA ACTA, 1998, 377 (2-3) :157-166
[8]   SELECTIVE DETERMINATION OF ARSENITE BY FLOW-INJECTION SPECTROPHOTOMETRY [J].
FRENZEL, W ;
TITZENTHALER, F ;
ELBEL, S .
TALANTA, 1994, 41 (11) :1965-1971
[9]   Spectrophotometric determination of phosphate and silicate by sequential injection using molybdenum blue chemistry [J].
Galhardo, CX ;
Masini, JC .
ANALYTICA CHIMICA ACTA, 2000, 417 (02) :191-200
[10]   Spectrophotometric determination of silicate in rain and aerosols by flow analysis [J].
Giacomelli, MC ;
Largiuni, O ;
Piccardi, G .
ANALYTICA CHIMICA ACTA, 1999, 396 (2-3) :285-292